메뉴 건너뛰기




Volumn 7259, Issue , 2009, Pages

An MRI-guided PET partial volume correction method

Author keywords

Deconvolution; Partial volume effects; PET MRI

Indexed keywords

ANATOMICAL INFORMATION; BAYESIAN; CANCER TREATMENT; HIGH RESOLUTION; MAGNETIC RESONANCE IMAGES; MR IMAGES; PARTIAL VOLUME CORRECTION; PARTIAL VOLUME EFFECT; PARTIAL VOLUME EFFECTS; PET DATA; PET IMAGES; PET IMAGING; POINT-SPREAD FUNCTION; POINT-SPREAD FUNCTIONS; PRIOR INFORMATION; SIMULATED PHANTOM; SPATIAL RESOLUTION;

EID: 71649108697     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.812474     Document Type: Conference Paper
Times cited : (2)

References (9)
  • 1
    • 0032034221 scopus 로고    scopus 로고
    • A nonlinear spatially variant object-dependent system model for prediction of partial volume effects and scatter in PET
    • C.H.Chen, R.F.Muzic, Jr., A.D.Nelson, and L.P.Adler, "A nonlinear spatially variant object-dependent system model for prediction of partial volume effects and scatter in PET," IEEE Trans Med Imaging 17, 214-227 (1998)
    • (1998) IEEE Trans Med Imaging , vol.17 , pp. 214-227
    • Chen, C.H.1    Muzic Jr., R.F.2    Nelson, A.D.3    Adler, L.P.4
  • 2
    • 0033757865 scopus 로고    scopus 로고
    • Importance of partial-volume correction in brain PET studies
    • F.Fazio and D.Perani, "Importance of partial-volume correction in brain PET studies," J Nucl.Med 41, 1849-1850 (2000)
    • (2000) J Nucl.Med , vol.41 , pp. 1849-1850
    • Fazio, F.1    Perani, D.2
  • 3
    • 0032920128 scopus 로고    scopus 로고
    • Simultaneous recovery of size and radioactivity concentration of small spheroids with PET data
    • C.H.Chen, R.F.Muzic, Jr., A.D.Nelson, and L.P.Adler, "Simultaneous recovery of size and radioactivity concentration of small spheroids with PET data," J Nucl.Med 40, 118-130 (1999)
    • (1999) J Nucl.Med , vol.40 , pp. 118-130
    • Chen, C.H.1    Muzic Jr., R.F.2    Nelson, A.D.3    Adler, L.P.4
  • 5
    • 0036898673 scopus 로고    scopus 로고
    • Correction of partial-volume effect for PET striatal imaging: Fast implementation and study of robustness
    • V.Frouin, C.Comtat, A.Reilhac, and M.C.Gregoire, "Correction of partial-volume effect for PET striatal imaging: fast implementation and study of robustness," J Nucl.Med 43, 1715-1726 (2002)
    • (2002) J Nucl.Med , vol.43 , pp. 1715-1726
    • Frouin, V.1    Comtat, C.2    Reilhac, A.3    Gregoire, M.C.4
  • 6
    • 0031955835 scopus 로고    scopus 로고
    • Correction for partial volume effects in PET: Principle and validation
    • O.G.Rousset, Y.Ma, and A.C.Evans, "Correction for partial volume effects in PET: principle and validation," J Nucl.Med 39, 904-911 (1998)
    • (1998) J Nucl.Med , vol.39 , pp. 904-911
    • Rousset, O.G.1    Ma, Y.2    Evans, A.C.3
  • 7
    • 34250315240 scopus 로고    scopus 로고
    • Partial-volume effect in PET tumor imaging
    • M.Soret, S.L.Bacharach, and I.Buvat, "Partial-volume effect in PET tumor imaging," J Nucl.Med 48, 932-945 (2007)
    • (2007) J Nucl.Med , vol.48 , pp. 932-945
    • Soret, M.1    Bacharach, S.L.2    Buvat, I.3
  • 8
    • 33745245573 scopus 로고    scopus 로고
    • Algorithm 851: CG-DESCENT, a conjugate gradient method with guaranteed descent
    • W.W.Hager and H.Zhang, "Algorithm 851: CG-DESCENT, a conjugate gradient method with guaranteed descent," ACM transcations on Mathmatical Softwares 32, 113-137 (2006)
    • (2006) ACM transcations on Mathmatical Softwares , vol.32 , pp. 113-137
    • Hager, W.W.1    Zhang, H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.