메뉴 건너뛰기




Volumn 91, Issue 2, 2009, Pages 626-630

Sterilization of medical devices by ethylene oxide, determination of the dissipation of residues, and use of green fluorescent protein as an indicator of process control

Author keywords

Biosensor; Measurement assessment; Membrane oxygenator; Sterilization

Indexed keywords

4-H CYCLES; AERATION PROCESS; BACILLUS ATROPHAEUS; BIOLOGICAL INDICATORS; ETHYLENE OXIDES; EXCESSIVE AERATION; GREEN FLUORESCENT PROTEIN; HEART SURGERY; MEASUREMENT/ASSESSMENT; MEDICAL DEVICES; MEMBRANE OXYGENATORS; RESIDUAL LEVELS; STERILIZATION CYCLE; STERILIZATION PROCESS;

EID: 71649093377     PISSN: 15524973     EISSN: 15524981     Source Type: Journal    
DOI: 10.1002/jbm.b.31438     Document Type: Article
Times cited : (10)

References (21)
  • 2
    • 0037813128 scopus 로고    scopus 로고
    • The performance of gamma-and-sterilised UHMWPE acetabular cups tested under severe simulator conditions. II. Wear particle characteristics with isolation protocols
    • Affatato S, Bersaglia G, Emiliani D, Foltran I, Taddei P, Reggiani M, Ferrieri P, Toni A. The performance of gamma-and-sterilised UHMWPE acetabular cups tested under severe simulator conditions. II. Wear particle characteristics with isolation protocols. Biomaterials 2003;24:4045-4055.
    • (2003) Biomaterials , vol.24 , pp. 4045-4055
    • Affatato, S.1    Bersaglia, G.2    Emiliani, D.3    Foltran, I.4    Taddei, P.5    Reggiani, M.6    Ferrieri, P.7    Toni, A.8
  • 4
    • 0020147385 scopus 로고
    • Ethylene oxide sterilization of medical devices with special reference to the sporicidal activity and residual concentration of ethylene oxide and its secondary products
    • Furuhashi M, Miyamae T. Ethylene oxide sterilization of medical devices with special reference to the sporicidal activity and residual concentration of ethylene oxide and its secondary products. Bull Tokyo Med Dent Univ 1982;29:23-35.
    • (1982) Bull Tokyo Med Dent Univ , vol.29 , pp. 23-35
    • Furuhashi, M.1    Miyamae, T.2
  • 9
    • 0003957716 scopus 로고    scopus 로고
    • Washington, DC/Champlain, NY: Association for Professionals in Infection Control and Epidemiology, Inc./ Polyscience Publications, Inc.
    • Rutala WA. Disinfection Sterilization and Antisepsis in Health Care. Washington, DC/Champlain, NY: Association for Professionals in Infection Control and Epidemiology, Inc./ Polyscience Publications, Inc.; 1998.
    • (1998) Disinfection Sterilization and Antisepsis in Health Care
    • Rutala, W.A.1
  • 10
    • 34547868920 scopus 로고    scopus 로고
    • Preliminary study on the potential utility of GFP as a biosensor for drug stability in parenteral solutions
    • DOI 10.1021/bp070090c
    • Santos CA, Mazzola PG, Silva PHS, Cholewa O, Penna TCV. Preliminary study on the potential utility of GFP as a biosensor for drug stability in parenteral solutions. Biotechnol Prog 2007;23:979-984. (Pubitemid 47255087)
    • (2007) Biotechnology Progress , vol.23 , Issue.4 , pp. 979-984
    • Dos Santos, C.A.1    Mazzola, P.G.2    Silva, P.H.S.3    Cholewa, O.4    Penna, T.C.V.5
  • 12
    • 33845532084 scopus 로고    scopus 로고
    • Stability of green fluorescent protein (GFP) in chlorine solutions of varying pH
    • DOI 10.1021/bp060217i
    • Mazzola PG, Ishii M, Chau E, Cholewa O, Penna TCV. Stability of green fluorescent protein (GFP) in chlorine solutions of varying pH. Biotechnol Prog 2006;22:1702-1707. (Pubitemid 44920132)
    • (2006) Biotechnology Progress , vol.22 , Issue.6 , pp. 1702-1707
    • Mazzola, P.G.1    Ishii, M.2    Chau, E.3    Cholewa, O.4    Penna, T.C.V.5
  • 14
    • 34249113112 scopus 로고    scopus 로고
    • Study on the thermal stability of green fluorescent protein (GFP) in glucose parenteral formulations
    • DOI 10.1016/j.ijpharm.2006.12.041, PII S0378517307000117
    • Ishii M, Kunimura JS, Vessoni Penna TC, Cholewa O. Study on the thermal stability of green fluorescent protein (GFP) in glucose parenteral formulations. Int J Pharm Sci 2007;337: 109-117. (Pubitemid 46778955)
    • (2007) International Journal of Pharmaceutics , vol.337 , Issue.1-2 , pp. 109-117
    • Ishii, M.1    Kunimura, J.S.2    Penna, T.C.V.3    Cholewa, O.4
  • 17
    • 0034758716 scopus 로고    scopus 로고
    • Validation of sterilisation process with ethylene oxide
    • Hücher G, Machmerth R, Kramer A. Validation of sterilisation process with ethylene oxide. Zent Steriliz 2001;9: 335-345.
    • (2001) Zent Steriliz , vol.9 , pp. 335-345
    • Hücher, G.1    Machmerth, R.2    Kramer, A.3
  • 18
    • 0022709909 scopus 로고
    • Aeration of ethylene oxide-sterilized polymers
    • Vink P, Pleijsier K. Aeration of ethylene oxide-sterilized polymers. Biomaterials 1986;7:225-230.
    • (1986) Biomaterials , vol.7 , pp. 225-230
    • Vink, P.1    Pleijsier, K.2
  • 19
    • 0034801361 scopus 로고    scopus 로고
    • Assessment of parameters associated to the risk of PVC catheter reuse
    • DOI 10.1002/jbm.1047
    • Granados DL, Jiménez A, Cuadrado TR. Assessment of parameters associated to the risk of PVC catheter reuse. J Biomed Mater Res B Appl Biomater 2001;58:505-510. (Pubitemid 32899905)
    • (2001) Journal of Biomedical Materials Research , vol.58 , Issue.5 , pp. 505-510
    • Granados, D.L.1    Jimenez, A.2    Cuadrado, T.R.3
  • 21
    • 0018965190 scopus 로고
    • Ethylene oxide sterilization: Effect of polymer structure and sterilization conditions on residue levels
    • Gilding DK, Reed AM, Baskett SA. Ethylene oxide sterilization: Effect of polymer structure and sterilization conditions on residue levels. Biomaterials 1980;1:145-148.
    • (1980) Biomaterials , vol.1 , pp. 145-148
    • Gilding, D.K.1    Reed, A.M.2    Baskett, S.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.