메뉴 건너뛰기




Volumn 7519, Issue , 2009, Pages

The biocompatibility of the dermal injection of glycerol in vivo to achieve optical clearing

Author keywords

Biocompatibility; Glycerol; Skin; Tissue optical clearing technique

Indexed keywords

BLOOD FLOW; COLLAGEN FIBER; DERMAL LAYERS; HIGH CONCENTRATION; IN-VESSEL; IN-VIVO; LASER SPECKLE CONTRAST IMAGING; OPTICAL CLEARING; OPTICAL CLEARING AGENTS; SKIN SAMPLES; SKIN TISSUE;

EID: 71549145634     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.843506     Document Type: Conference Paper
Times cited : (10)

References (14)
  • 1
    • 49649111688 scopus 로고    scopus 로고
    • Influence of alcohols on the optical clearing effect of skin in vitro
    • Z. Mao, D. Zhu, Y. Hu, X. Wen and Z. Han "Influence of alcohols on the optical clearing effect of skin in vitro," J. Biomed. Opt., 13 (2) :021104 (2008).
    • (2008) J. Biomed. Opt , vol.13 , Issue.2 , pp. 021104
    • Mao, Z.1    Zhu, D.2    Hu, Y.3    Wen, X.4    Han, Z.5
  • 2
    • 0037928110 scopus 로고    scopus 로고
    • Morphological changes in blood vessels produced by hyperosmotic agents and measured by optical coherence tomography
    • G. Vargas, A. Readinger, S. S. Dosier, and A.J. Welch, "Morphological changes in blood vessels produced by hyperosmotic agents and measured by optical coherence tomography," Photochem. Photobiol., 77 (5): 541-549 (2003).
    • (2003) Photochem. Photobiol , vol.77 , Issue.5 , pp. 541-549
    • Vargas, G.1    Readinger, A.2    Dosier, S.S.3    Welch, A.J.4
  • 5
    • 0141829177 scopus 로고    scopus 로고
    • Injection of glycerol into porcine skin for optical skin clearing with needle-free injection gun and determination of agent distribution using OCT and fluorescence microscopy
    • O. F. Stumpp and A. J. Welch, "Injection of glycerol into porcine skin for optical skin clearing with needle-free injection gun and determination of agent distribution using OCT and fluorescence microscopy," Proc. SPIE 4949: 44-50 (2003).
    • (2003) Proc. SPIE , vol.4949 , pp. 44-50
    • Stumpp, O.F.1    Welch, A.J.2
  • 6
    • 27744587861 scopus 로고    scopus 로고
    • Enhancement of transdermal skin clearing agent delivery using a 980 nm diode Laser
    • O. F. Stumpp, A. J. Welch, T.E. Milner, and J. Neev, "Enhancement of transdermal skin clearing agent delivery using a 980 nm diode Laser," Lasers Surg. Med., 37(4): 278-85 (2005).
    • (2005) Lasers Surg. Med , vol.37 , Issue.4 , pp. 278-285
    • Stumpp, O.F.1    Welch, A.J.2    Milner, T.E.3    Neev, J.4
  • 7
    • 65949112492 scopus 로고    scopus 로고
    • Influence of glycerol with different concentration on skin optical clearing and morphological changes in vivo
    • Z. Mao, Z. Han, X. Wen, Q. Luo and D. Zhu, "Influence of glycerol with different concentration on skin optical clearing and morphological changes in vivo," Proc. SPIE., 7278: 72781T (2009).
    • (2009) Proc. SPIE , vol.7278
    • Mao, Z.1    Han, Z.2    Wen, X.3    Luo, Q.4    Zhu, D.5
  • 8
    • 0018639351 scopus 로고
    • A transparent access chamber for the rat dorsal skin flap
    • H. D. Papenfuss, J. F.Gross, M. Intaglietta, et al., "A transparent access chamber for the rat dorsal skin flap," Microvas. Res., 18: 311-318 (1979).
    • (1979) Microvas. Res , vol.18 , pp. 311-318
    • Papenfuss, H.D.1    Gross, J.F.2    Intaglietta, M.3
  • 9
    • 9144236980 scopus 로고    scopus 로고
    • Hyperosmotic chemical agent's effect on in vivo cerebral blood flow revealed by laser speckle
    • H. Cheng, Q Luo., S. Zeng, et al., "Hyperosmotic chemical agent's effect on in vivo cerebral blood flow revealed by laser speckle," Appl. Opt., 43: 5772-5777 (2004).
    • (2004) Appl. Opt , vol.43 , pp. 5772-5777
    • Cheng, H.1    Luo, Q.2    Zeng, S.3
  • 10
    • 67249159636 scopus 로고    scopus 로고
    • Accessing the structure and function information of deep skin blood vessels with noninvasive optical method
    • J. Wang, Z. Zhi, Z. Han, C. Liu, Z. Mao, X. Wen and D. Zhu, "Accessing the structure and function information of deep skin blood vessels with noninvasive optical method, " Proc. SPIE., 7176: 71760Q (2009).
    • (2009) Proc. SPIE , vol.7176
    • Wang, J.1    Zhi, Z.2    Han, Z.3    Liu, C.4    Mao, Z.5    Wen, X.6    Zhu, D.7
  • 11
    • 33744469104 scopus 로고    scopus 로고
    • Molecular interactions of exogenous chemical agents with collagen- implications for tissue optical clearing
    • A. T. Yeh and J. Hirshburg, "Molecular interactions of exogenous chemical agents with collagen- implications for tissue optical clearing," J. Biomed., Opt., 11(1): 014003 (2006).
    • (2006) J. Biomed., Opt , vol.11 , Issue.1 , pp. 014003
    • Yeh, A.T.1    Hirshburg, J.2
  • 12
    • 49649086181 scopus 로고    scopus 로고
    • Short-term and long-term effects of optical clearing agents on blood vessels in chick chorioallantoic membrane
    • D. Zhu, J. Zhang, H. Cui and Z. Mao, "Short-term and long-term effects of optical clearing agents on blood vessels in chick chorioallantoic membrane," J. Biomed. Opt., 13 (2) : 021106 (2008).
    • (2008) J. Biomed. Opt , vol.13 , Issue.2 , pp. 021106
    • Zhu, D.1    Zhang, J.2    Cui, H.3    Mao, Z.4
  • 13
    • 71549155458 scopus 로고    scopus 로고
    • L. T. Muller1, D. S. Gombos, C. K. Mishra1, C. A. Gunderson1 and C. J. Calvano, Biocompatability studies of a novel biomaterial for ocular surface reconstruction, Invest Ophthalmol Vis Sci, 43: 1110 (2002).
    • L. T. Muller1, D. S. Gombos, C. K. Mishra1, C. A. Gunderson1 and C. J. Calvano, "Biocompatability studies of a novel biomaterial for ocular surface reconstruction, " Invest Ophthalmol Vis Sci, 43: 1110 (2002).
  • 14
    • 0033517707 scopus 로고    scopus 로고
    • Improving the durability of total joint replacement
    • J. P. Waddell, "Improving the durability of total joint replacement," CMAJ Specialty Spotlight, 161 (9): 1141 (1999).
    • (1999) CMAJ Specialty Spotlight , vol.161 , Issue.9 , pp. 1141
    • Waddell, J.P.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.