메뉴 건너뛰기




Volumn , Issue , 2009, Pages 1806-1809

Flexible enzyme free glucose micro-sensor for continuous monitoring applications

Author keywords

Continuous monitoring; Enzyme free; Flexible; Glucose; Micro sensor; Nanoporous PT; PET

Indexed keywords

AU ELECTRODES; CONTINUOUS GLUCOSE MONITORING; CONTINUOUS MONITORING; CORRELATION COEFFICIENT; ELECTRODE SURFACES; FABRICATED SENSORS; FLEXIBLE SENSOR; GLUCOSE CONCENTRATION; HIGH SENSITIVITY; LOW DETECTION LIMIT; NANO-POROUS; ROUGHNESS FACTOR; WORKING ELECTRODE;

EID: 71449109146     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/SENSOR.2009.5285725     Document Type: Conference Paper
Times cited : (10)

References (10)
  • 1
    • 0025411996 scopus 로고
    • Chemical sensors for bedside monitoring of critically ill patients
    • M.E. Collison, M.E. Meyerhoff, "Chemical sensors for bedside monitoring of critically ill patients", Anal. Chem., vol. 62, pp. 425A-437A, 1990.
    • (1990) Anal. Chem , vol.62
    • Collison, M.E.1    Meyerhoff, M.E.2
  • 2
    • 84987505923 scopus 로고    scopus 로고
    • Electrochemical transducers for in vivo monitoring
    • P. Vadgama, M. Desai, P. Crump, "Electrochemical transducers for in vivo monitoring", Electroanalysis, vol. 3, pp. 597-606, 2005.
    • (2005) Electroanalysis , vol.3 , pp. 597-606
    • Vadgama, P.1    Desai, M.2    Crump, P.3
  • 3
    • 29944443113 scopus 로고    scopus 로고
    • Electrochemical non-enzymatic glucose sensors
    • S.J. Park, H.K. Boo, T.D. Chung, "Electrochemical non-enzymatic glucose sensors", Anal. Chim. Acta, vol. 556, pp. 46-57, 2006.
    • (2006) Anal. Chim. Acta , vol.556 , pp. 46-57
    • Park, S.J.1    Boo, H.K.2    Chung, T.D.3
  • 4
    • 26944446945 scopus 로고    scopus 로고
    • Novel micromachined silicon sensor for continuous glucose monitoring
    • G. Piechotta, J. Albers, R. Hintsche, "Novel micromachined silicon sensor for continuous glucose monitoring", Biosen. Bioelectron., vol. 21, pp. 802-808, 2005.
    • (2005) Biosen. Bioelectron , vol.21 , pp. 802-808
    • Piechotta, G.1    Albers, J.2    Hintsche, R.3
  • 5
    • 33749261409 scopus 로고    scopus 로고
    • A flexible and wearable glucose sensor based on functional polymers with Soft-MEMS techniques
    • H. Kudo, T. Swada, E. Kazawa, H. Yoshida, Y. Lwasaki, K. Mitsubayashi, "A flexible and wearable glucose sensor based on functional polymers with Soft-MEMS techniques", Biosen. Bioelectron., vol. 22, pp. 558-562, 2006.
    • (2006) Biosen. Bioelectron , vol.22 , pp. 558-562
    • Kudo, H.1    Swada, T.2    Kazawa, E.3    Yoshida, H.4    Lwasaki, Y.5    Mitsubayashi, K.6
  • 6
    • 0035122561 scopus 로고    scopus 로고
    • Beneficial Use of Fibroblast Growth Factor 2 and RGTA, a New Family of Heparan Mimics, for Endothelialization of PET Prostheses
    • P. Desgranges, J.P. Caruelle, G. Carpentier, D. Barritault, M. Tardieu, "Beneficial Use of Fibroblast Growth Factor 2 and RGTA, a New Family of Heparan Mimics, for Endothelialization of PET Prostheses", Biomed. Mater. Res., vol. 58, pp. 1-9, 2001.
    • (2001) Biomed. Mater. Res , vol.58 , pp. 1-9
    • Desgranges, P.1    Caruelle, J.P.2    Carpentier, G.3    Barritault, D.4    Tardieu, M.5
  • 8
    • 43949124466 scopus 로고    scopus 로고
    • Fabrication and characterization of platinum black and mesoporous platinum electrodes for in-vivo and continuously monitoring electrochemical sensor application
    • H.K. Seo, D.J. Park, J.Y. Park, "Fabrication and characterization of platinum black and mesoporous platinum electrodes for in-vivo and continuously monitoring electrochemical sensor application", Thin Solid Films, vol. 516, pp. 5227-5230, 2008.
    • (2008) Thin Solid Films , vol.516 , pp. 5227-5230
    • Seo, H.K.1    Park, D.J.2    Park, J.Y.3
  • 9
    • 55249083796 scopus 로고    scopus 로고
    • Fabrication and Optimization of a Nanoporous Platinum Electrode and a Non-enzymatic Glucose Micro-sensor on Silicon
    • Yi-Jae Lee, Dae-Joon Park, Jae-Yeong Park, "Fabrication and Optimization of a Nanoporous Platinum Electrode and a Non-enzymatic Glucose Micro-sensor on Silicon", SENSORS-BASEL, vol. 8, pp. 6154-6164, 2008.
    • (2008) SENSORS-BASEL , vol.8 , pp. 6154-6164
    • Lee, Y.-J.1    Park, D.-J.2    Park, J.-Y.3
  • 10
    • 0000589512 scopus 로고
    • Limiting oxygen coverage on platinized platinum; relevance to determination of real platinum area by hydrogen adsorption
    • T. Biegler, D.A.J. Rand, R. Woods, "Limiting oxygen coverage on platinized platinum; relevance to determination of real platinum area by hydrogen adsorption", J. Electroanal. Chem., vol. 29, pp. 269-277, 1971
    • (1971) J. Electroanal. Chem , vol.29 , pp. 269-277
    • Biegler, T.1    Rand, D.A.J.2    Woods, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.