메뉴 건너뛰기




Volumn 395, Issue 7, 2009, Pages 2415-2421

Droplet-based magnetically activated cell separation: Analysis of separation efficiency based on the variation of flow-induced circulation in a pendent drop

Author keywords

Cell separation; Droplet based magnetically activated cell separation; Flow induced circulation; Magnet; Pendent drop

Indexed keywords

BUFFER SOLUTIONS; CELL SEPARATION; DROPLET-BASED MAGNETICALLY ACTIVATED CELL SEPARATION; DURATION TIME; FLOW-INDUCED CIRCULATION; INJECTION FLOW RATE; LOW RATES; MAGNETICALLY ACTIVATED CELL SEPARATIONS; MORPHOLOGICAL CHARACTERISTIC; SEPARATION EFFICIENCY; SPECIFIC VOLUME;

EID: 71449103213     PISSN: 16182642     EISSN: 16182650     Source Type: Journal    
DOI: 10.1007/s00216-009-3131-z     Document Type: Conference Paper
Times cited : (2)

References (16)
  • 3
    • 23844533295 scopus 로고    scopus 로고
    • Blood-on-a-chip
    • DOI 10.1146/annurev.bioeng.7.011205.135108
    • M Toner D Irimia 2005 Annu Rev Biomed Eng 7 77 103 10.1146/annurev. bioeng.7.011205.135108 1:CAS:528:DC%2BD2MXps12ltL4%3D (Pubitemid 41174581)
    • (2005) Annual Review of Biomedical Engineering , vol.7 , pp. 77-103
    • Toner, M.1    Irimia, D.2
  • 4
    • 0034767092 scopus 로고    scopus 로고
    • Design of a microfabricated magnetic cell separator
    • DOI 10.1002/1522-2683(200110)22:18<3883::AID-ELPS3883>3.0.CO;2-4
    • M Berger J Castelino R Huang M Shah RH Austin 2001 Electrophoresis 22 3883 3892 10.1002/1522-2683(200110)22:18<3883::AID-ELPS3883>3.0.CO;2-4 1:CAS:528:DC%2BD3MXot12gsLY%3D (Pubitemid 33040205)
    • (2001) Electrophoresis , vol.22 , Issue.18 , pp. 3883-3892
    • Berger, M.1    Castelino, J.2    Huang, R.3    Shah, M.4    Austin, R.H.5
  • 5
    • 21144444795 scopus 로고    scopus 로고
    • 1:CAS:528:DC%2BD2MXos1ektLk%3D
    • MAM Gijs 2004 Microfluid Nanofluid 1 22 40 1:CAS:528:DC%2BD2MXos1ektLk%3D
    • (2004) Microfluid Nanofluid , vol.1 , pp. 22-40
    • Gijs, M.A.M.1
  • 7
    • 79956047064 scopus 로고    scopus 로고
    • Fabrication of magnetic microfiltration systems using soft lithography
    • DOI 10.1063/1.1436282
    • T Deng M Prentiss GM Whitesides 2002 Appl Phys Lett 80 461 463 10.1063/1.1436282 1:CAS:528:DC%2BD38XlsFeqsA%3D%3D (Pubitemid 34105382)
    • (2002) Applied Physics Letters , vol.80 , Issue.3 , pp. 461
    • Deng, T.1    Prentiss, M.2    Whitesides, G.M.3
  • 9
    • 4344609712 scopus 로고    scopus 로고
    • 10.1063/1.1776339 1:CAS:528:DC%2BD2cXmsVWgs7w%3D
    • H Lee AM Purdon RM Westervelt 2004 Appl Phys Lett 85 1063 1065 10.1063/1.1776339 1:CAS:528:DC%2BD2cXmsVWgs7w%3D
    • (2004) Appl Phys Lett , vol.85 , pp. 1063-1065
    • Lee, H.1    Purdon, A.M.2    Westervelt, R.M.3
  • 10
    • 33745158640 scopus 로고    scopus 로고
    • Fabrication of three-dimensional magnetic microdevices with embedded microcoils for magnetic potential concentration
    • DOI 10.1109/JMEMS.2006.876788
    • Q Ramadan V Samper D Poenar C Yu 2006 J Microelectromech Syst 15 624 638 10.1109/JMEMS.2006.876788 1:CAS:528:DC%2BD28XmslOqtL0%3D (Pubitemid 43895744)
    • (2006) Journal of Microelectromechanical Systems , vol.15 , Issue.3 , pp. 624-638
    • Ramadan, Q.1    Samper, V.D.2    Puiu, D.P.3    Yu, C.4
  • 15
    • 0038046192 scopus 로고    scopus 로고
    • Synthesis, permeability and biocompatibility of tricomponent membranes containing polyethylene glycol, polydimethylsiloxane and polypentamethylcyclopentasiloxane domains
    • DOI 10.1016/S0142-9612(03)00189-3
    • P Kurian B Kasibhatla J Daum CA Burns M Moosa KS Rosenthal JP Kennedy 2003 Biomaterials 24 3493 3503 10.1016/S0142-9612(03)00189-3 1:CAS:528:DC%2BD3sXktlOgt7c%3D (Pubitemid 36703123)
    • (2003) Biomaterials , vol.24 , Issue.20 , pp. 3493-3503
    • Kurian, P.1    Kasibhatla, B.2    Daum, J.3    Burns, C.A.4    Moosa, M.5    Rosenthal, K.S.6    Kennedy, J.P.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.