메뉴 건너뛰기




Volumn 14, Issue 1, 2010, Pages 31-35

How much force is required to dislodge an alternate airway?

Author keywords

Airway; Dislodgment; Force; Intratracheal; Intubation

Indexed keywords

ACCURACY; ADULT; ARTICLE; BODY HEIGHT; BODY WEIGHT; CADAVER; CLINICAL ASSESSMENT TOOL; COMPARATIVE STUDY; ENDOTRACHEAL TUBE; ESOPHAGEAL TRACHEAL COMBITUBE; EXPERIMENTAL MODEL; EXTUBATION; FEMALE; FORCE; HEAD CIRCUMFERENCE; HUMAN; HUMAN EXPERIMENT; KING LARYNGEAL TUBE DISPOSABLE AIRWAY; LARYNGEAL MASK; MALE; MEDICAL INSTRUMENTATION; NECK;

EID: 71449095422     PISSN: 10903127     EISSN: 15450066     Source Type: Journal    
DOI: 10.3109/10903120903349879     Document Type: Article
Times cited : (13)

References (20)
  • 1
    • 33845727968 scopus 로고    scopus 로고
    • Alternate airways in the prehospital setting [resource document for NAEMSP position statement]
    • Guyette FX, Greenwood MJ,Neubecker D, Roth R,WangHE. Alternate airways in the prehospital setting [resource document for NAEMSP position statement]. Prehosp Emerg Care. 2007;11:56-61.
    • (2007) Prehosp Emerg Care. , vol.11 , pp. 56-61
    • Guyette, F.X.1    Greenwood, M.J.2    Neubecker, D.3    Roth, R.4    Wang, H.E.5
  • 2
    • 0035148486 scopus 로고    scopus 로고
    • Misplaced endotracheal tubes by paramedics in an urban emergency medical services system
    • Katz SH, Falk JL. Misplaced endotracheal tubes by paramedics in an urban emergency medical services system. Ann Emerg Med. 2001;37:32-37
    • (2001) Ann Emerg Med. , vol.37 , pp. 32-37
    • Katz, S.H.1    Falk, J.L.2
  • 3
    • 0042836665 scopus 로고    scopus 로고
    • Unrecognized misplacement of endotracheal tubes in a mixed urban to rural emergency medical services setting
    • Jemmett ME, Kendal KM, Fourre MW, Burton JH. Unrecognized misplacement of endotracheal tubes in a mixed urban to rural emergency medical services setting. Acad Emerg Med. 2003;10:961-965
    • (2003) Acad Emerg Med. , vol.10 , pp. 961-965
    • Jemmett, M.E.1    Kendal, K.M.2    Fourre, M.W.3    Burton, J.H.4
  • 5
    • 34047155109 scopus 로고    scopus 로고
    • Unrecognized misplacement of endotracheal tubes by ground prehospital providers
    • Wirtz DD, Ortiz C, Newman DH, Zhitomirsky I. Unrecognized misplacement of endotracheal tubes by ground prehospital providers. Prehosp Emerg Care. 2007;11:213-218
    • (2007) Prehosp Emerg Care. , vol.11 , pp. 213-218
    • Wirtz, D.D.1    Ortiz, C.2    Newman, D.H.3    Zhitomirsky, I.4
  • 6
    • 36048959921 scopus 로고    scopus 로고
    • Extubation force: Tape versus endotracheal tube holders
    • Carlson J, Mayrose J, Krause R, Jehle D. Extubation force: tape versus endotracheal tube holders. Ann Emerg Med. 2007;50:686-691
    • (2007) Ann Emerg Med. , vol.50 , pp. 686-691
    • Carlson, J.1    Mayrose, J.2    Krause, R.3    Jehle, D.4
  • 7
    • 33644540485 scopus 로고    scopus 로고
    • Predictive performance of three multivariate difficult tracheal intubation models: A double-blind, case-controlled study
    • DOI 10.1213/01.ane.0000196507.19771.b2
    • Naguib M, Scamman FL, O'SulliVan C, et al. Predictive performance of three multivariate difficult tracheal intubation models: a double-blind, case-controlled study. Anesth Analg. 2006;102:818-824 (Pubitemid 43306402)
    • (2006) Anesthesia and Analgesia , vol.102 , Issue.3 , pp. 818-824
    • Naguib, M.1    Scamman, F.L.2    O'Sullivan, C.3    Aker, J.4    Ross, A.F.5    Kosmach, S.6    Ensor, J.E.7
  • 9
    • 0029188819 scopus 로고
    • Proper depth placement of oral endotracheal tubes in adults prior to radiographic confirmation
    • Roberts JR, Spadafora M, Cone DC. Proper depth placement of oral endotracheal tubes in adults prior to radiographic confirmation. Acad Emerg Med. 1995;2:20-24
    • (1995) Acad Emerg Med. , vol.2 , pp. 20-24
    • Roberts, J.R.1    Spadafora, M.2    Cone, D.C.3
  • 11
    • 13644258050 scopus 로고    scopus 로고
    • Endotracheal tube cuff pressure in three hospitals, and the volume required to produce an appropriate cuff pressure
    • Sengupta P, Sessler DI, Maglinger P, et al. Endotracheal tube cuff pressure in three hospitals, and the volume required to produce an appropriate cuff pressure. BMC Anesthesiol. 2004; 4:8.
    • (2004) BMC Anesthesiol , vol.4 , pp. 8
    • Sengupta, P.1    Sessler, D.I.2    Maglinger, P.3
  • 12
    • 10344259692 scopus 로고    scopus 로고
    • Alternative management techniques for the difficult airway: Esophageal-tracheal Combitube
    • Krafft P, Schebesta K. Alternative management techniques for the difficult airway: esophageal-tracheal Combitube. Curr Opin Anaesthesiol. 2004;17:499-504.
    • (2004) Curr Opin Anaesthesiol , vol.17 , pp. 499-504
    • Krafft, P.1    Schebesta, K.2
  • 13
  • 14
    • 71449090286 scopus 로고    scopus 로고
    • LMA North America. Available at: Accessed December 14, 2008
    • LMA North America. LMA Unique. Available at: http://www. lmana.com/unique.php. Accessed December 14, 2008.
    • LMA Unique
  • 15
    • 71449121788 scopus 로고    scopus 로고
    • Inc. King LT-D. Available at: Accessed December 14, 2008
    • King Systems, Inc. King LT-D. Available at: http://www. kingsystems.com/PRODUCTS/AirwayDevices/KINGLTD/ tabid/55/Default.aspx. Accessed December 14, 2008.
  • 16
    • 0028063843 scopus 로고
    • A comparison of four endotracheal tube holders
    • Kaplow R, Bookbinder M. A comparison of four endotracheal tube holders. Heart Lung. 1994;23:59-66.
    • (1994) Heart Lung. , vol.23 , pp. 59-66
    • Kaplow, R.1    Bookbinder, M.2
  • 17
    • 36049012732 scopus 로고    scopus 로고
    • Impact of new resuscitation guidelines on outof- hospital cardiac arrest survival [abstract]
    • FalesW, Farrell R. Impact of new resuscitation guidelines on outof- hospital cardiac arrest survival [abstract]. Acad Emerg Med. 2007;14(5 suppl):S157-S158.
    • (2007) Acad Emerg Med. , vol.14 , Issue.5 SUPPL.
    • Fales, W.1    Farrell, R.2
  • 18
    • 0021260456 scopus 로고
    • Endotracheal cuff pressure and tracheal mucosal blood flow: Endoscopic study of effects of four large volume cuffs
    • Seegobin RD, Van Hasselt GL. Endotracheal cuff pressure and tracheal mucosal blood flow: endoscopic study of effects of four large volume cuffs. BMJ. 1984;288:965-968
    • (1984) BMJ. , vol.288 , pp. 965-968
    • Seegobin, R.D.1    Van Hasselt, G.L.2
  • 19
    • 0030877560 scopus 로고    scopus 로고
    • Taping methods and tape types for securing oral endotracheal tubes
    • Patel N, Smith CE, Pinchak AC, Hancock DE. Taping methods and tape types for securing oral endotracheal tubes. Can J Anaesth. 1997;44:330-336
    • (1997) Can J Anaesth. , vol.44 , pp. 330-336
    • Patel, N.1    Smith, C.E.2    Pinchak, A.C.3    Hancock, D.E.4
  • 20
    • 0027451336 scopus 로고
    • Griego L.Acomparative study of oral endotracheal tube securing methods
    • Levy H, Griego L.Acomparative study of oral endotracheal tube securing methods. Chest. 1993;104:1537-2140
    • (1993) Chest , vol.104 , pp. 1537-2140
    • Levy, H.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.