메뉴 건너뛰기




Volumn 79, Issue 1, 1998, Pages 34-38

Clinical events following excimer laser angioplasty or balloon angioplasty for complex coronary lesions: Subanalysis of a randomised trial

Author keywords

Balloon angioplasty; Excimer laser angioplasty; Laser assisted balloon angioplasty; Randomised trial

Indexed keywords

ADULT; AGED; ANGIOCARDIOGRAPHY; ARTICLE; CARDIOVASCULAR DISEASE; CLINICAL TRIAL; CORONARY ARTERY BYPASS GRAFT; CORONARY ARTERY DISEASE; EXCIMER LASER; FEMALE; FOLLOW UP; HEART INFARCTION; HUMAN; INTERMETHOD COMPARISON; LASER ANGIOPLASTY; MAJOR CLINICAL STUDY; MALE; PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY; PRIORITY JOURNAL; TREATMENT OUTCOME;

EID: 7144257199     PISSN: 13556037     EISSN: None     Source Type: Journal    
DOI: 10.1136/hrt.79.1.34     Document Type: Article
Times cited : (15)

References (29)
  • 1
    • 0021949810 scopus 로고
    • Laser ablation of human atherosclerotic plaque without adjacent tissue injury
    • Grundfest WS, Litvack F, Forrester JS, et al. Laser ablation of human atherosclerotic plaque without adjacent tissue injury. J Am Coll Cardiol 1985;5:929-33.
    • (1985) J Am Coll Cardiol , vol.5 , pp. 929-933
    • Grundfest, W.S.1    Litvack, F.2    Forrester, J.S.3
  • 2
    • 0022350284 scopus 로고
    • The excimer laser: Gross, light microscopic and ultrastructural analysis of potential advantages for use in laser therapy of cardiovascular disease
    • Isner JM, Donaldson RF, Deckelbaum LI, et al. The excimer laser: gross, light microscopic and ultrastructural analysis of potential advantages for use in laser therapy of cardiovascular disease. J Am Coll Cardiol 1985;6:1102-9.
    • (1985) J Am Coll Cardiol , vol.6 , pp. 1102-1109
    • Isner, J.M.1    Donaldson, R.F.2    Deckelbaum, L.I.3
  • 3
    • 0023463878 scopus 로고
    • Tissue interactions and measurement of ablation rates with ultraviolet and visible lasers in canine and human arteries
    • Sartori M, Henry PD, Sauerbrey R, et al. Tissue interactions and measurement of ablation rates with ultraviolet and visible lasers in canine and human arteries. Lasers Surg Med 1987;7:300-6.
    • (1987) Lasers Surg Med , vol.7 , pp. 300-306
    • Sartori, M.1    Henry, P.D.2    Sauerbrey, R.3
  • 4
    • 0027062846 scopus 로고
    • Clinical success, complications and restenosis rates with excimer laser coronary angioplasty, the percutaneous excimer laser coronary angioplasty registry
    • Bittl JA, Sanborn TA, Tcheng JE, et al. Clinical success, complications and restenosis rates with excimer laser coronary angioplasty, the percutaneous excimer laser coronary angioplasty registry. Am J Cardiol 1992;70:1533-9.
    • (1992) Am J Cardiol , vol.70 , pp. 1533-1539
    • Bittl, J.A.1    Sanborn, T.A.2    Tcheng, J.E.3
  • 6
    • 0025769196 scopus 로고
    • Percutaneous excimer laser coronary angioplasty of lesions not ideal for balloon angioplasty
    • Cook SL, Eigler NL, Shefer A, et al. Percutaneous excimer laser coronary angioplasty of lesions not ideal for balloon angioplasty. Circulation 1991;84:632-43.
    • (1991) Circulation , vol.84 , pp. 632-643
    • Cook, S.L.1    Eigler, N.L.2    Shefer, A.3
  • 7
    • 0026720943 scopus 로고
    • Excimer laser-facilitated coronary angioplasty. Relative risk analysis of acute and follow-up results in 200 patients
    • Bittl JA, Sanborn TA. Excimer laser-facilitated coronary angioplasty. Relative risk analysis of acute and follow-up results in 200 patients. Circulation 1992;86:71-80.
    • (1992) Circulation , vol.86 , pp. 71-80
    • Bittl, J.A.1    Sanborn, T.A.2
  • 8
    • 0027407608 scopus 로고
    • Excimer laser coronary angioplasty in the Netherlands: Preamble for a randomized study
    • Strikwerda S, Koolen JJ, de Feyter PJ, et al. Excimer laser coronary angioplasty in the Netherlands: preamble for a randomized study. Am Heart J 1993;125:838-47.
    • (1993) Am Heart J , vol.125 , pp. 838-847
    • Strikwerda, S.1    Koolen, J.J.2    De Feyter, P.J.3
  • 9
    • 13344295081 scopus 로고    scopus 로고
    • Randomised trial of excimer laser angioplasty versus balloon angioplasty for treatment of obstructive coronary artery disease
    • Appelman YEA, Pick JJ, Strikwerda S, et al. Randomised trial of excimer laser angioplasty versus balloon angioplasty for treatment of obstructive coronary artery disease. Lancet 1996;347:79-84.
    • (1996) Lancet , vol.347 , pp. 79-84
    • Appelman, Y.E.A.1    Pick, J.J.2    Strikwerda, S.3
  • 10
    • 0021916187 scopus 로고
    • The thrombolysis in myocardial infarction (TIMI) trial: Phase I findings
    • The TIMI Study Group. The thrombolysis in myocardial infarction (TIMI) trial: phase I findings. N Engl J Med 1985;312:932-6.
    • (1985) N Engl J Med , vol.312 , pp. 932-936
  • 12
    • 0016998022 scopus 로고
    • Grading of angina pectoris
    • Campeau L. Grading of angina pectoris. Circulation 1976;54:522-3.
    • (1976) Circulation , vol.54 , pp. 522-523
    • Campeau, L.1
  • 13
    • 0025542168 scopus 로고
    • Coronary morphologic and clinical determinants of procedural outcome with angioplasty for multivesssel coronary disease
    • Ellis SG, Vandormael MG, Cowley MJ, et al, and the Multivessel Angioplasty Prognosis Study Group. Coronary morphologic and clinical determinants of procedural outcome with angioplasty for multivesssel coronary disease. Circulation 1990;82:1193-202.
    • (1990) Circulation , vol.82 , pp. 1193-1202
    • Ellis, S.G.1    Vandormael, M.G.2    Cowley, M.J.3
  • 14
    • 0028064002 scopus 로고
    • Percutaneous excimer laser coronary angioplasty: Results in the first consecutive 3,000 patients
    • Litvack F, Eigler N, Margolis J, et al, for the ELCA investigators. Percutaneous excimer laser coronary angioplasty: results in the first consecutive 3,000 patients. J Am Coll Cardiol 1994;23:323-9.
    • (1994) J Am Coll Cardiol , vol.23 , pp. 323-329
    • Litvack, F.1    Eigler, N.2    Margolis, J.3
  • 15
    • 0028289212 scopus 로고
    • Clinical results of coronary excimer laser angioplasty: Report from the European coronary excimer laser angioplasty registry
    • Baumbach A, Oswald H, Kvasnicka J, et al, and the coinvestigators of the European Coronary Excimer Laser Angioplasty Registry. Clinical results of coronary excimer laser angioplasty: report from the European coronary excimer laser angioplasty registry. Eur Heart J 1994;15:89-96.
    • (1994) Eur Heart J , vol.15 , pp. 89-96
    • Baumbach, A.1    Oswald, H.2    Kvasnicka, J.3
  • 16
    • 0025793370 scopus 로고
    • Incidence and clinical significance of transient creatine kinase elevations and the diagnosis of non-Q wave myocardial infarction associated with coronary angioplasty
    • Klein LW, Kramer BL, Howard E, et al. Incidence and clinical significance of transient creatine kinase elevations and the diagnosis of non-Q wave myocardial infarction associated with coronary angioplasty. J Am Coll Cardiol 1991;17:621-6.
    • (1991) J Am Coll Cardiol , vol.17 , pp. 621-626
    • Klein, L.W.1    Kramer, B.L.2    Howard, E.3
  • 17
    • 0027971652 scopus 로고
    • Elevation of the creatine kinase myocardial isoform following otherwise successful directional coronary atherectomy and stenting
    • Kugelmass AD, Cohen J, Moscuccie M, et al. Elevation of the creatine kinase myocardial isoform following otherwise successful directional coronary atherectomy and stenting. Am J Cardiol 1994;74:748-54.
    • (1994) Am J Cardiol , vol.74 , pp. 748-754
    • Kugelmass, A.D.1    Cohen, J.2    Moscuccie, M.3
  • 18
    • 0030752359 scopus 로고    scopus 로고
    • Randomized comparison of angioplasty of complex coronary lesions at a single center. Excimer laser, rotational atherectomy, and balloon angioplasty comparison (ERBAC) study
    • Reifart N, Vandormael M, Krajcar M, et al. Randomized comparison of angioplasty of complex coronary lesions at a single center. Excimer laser, rotational atherectomy, and balloon angioplasty comparison (ERBAC) study. Circulation 1997;96:91-8.
    • (1997) Circulation , vol.96 , pp. 91-98
    • Reifart, N.1    Vandormael, M.2    Krajcar, M.3
  • 19
    • 0026680326 scopus 로고
    • Origin of arterial wall dissections induced by pulsed excimer and mid-infrared laser ablation in the pig
    • Van Leeuwen TG, Van Erven L, Meertens JH, et al. Origin of arterial wall dissections induced by pulsed excimer and mid-infrared laser ablation in the pig. J Am Coll Cardiol 1992;19:1610-18.
    • (1992) J Am Coll Cardiol , vol.19 , pp. 1610-1618
    • Van Leeuwen, T.G.1    Van Erven, L.2    Meertens, J.H.3
  • 20
    • 7144245962 scopus 로고
    • Intraluminal vapour bubble induced by excimer laser pulse causes microsecond arterial dilatation and invagination leading ot extensive wall damage in the rabbit
    • Van Leeuwen TG, Meertens JH, Velema E, et al. Intraluminal vapour bubble induced by excimer laser pulse causes microsecond arterial dilatation and invagination leading ot extensive wall damage in the rabbit. Circulation 1993;93: 231-41.
    • (1993) Circulation , vol.93 , pp. 231-241
    • Van Leeuwen, T.G.1    Meertens, J.H.2    Velema, E.3
  • 21
    • 0028034262 scopus 로고
    • Intravascular ultrasound comparison of restenotic and de novo coronary artery narrowings
    • Mintz GS, Pichard AD, Kent KM, et al. Intravascular ultrasound comparison of restenotic and de novo coronary artery narrowings. Am J Cardiol 1994;74:1278-80.
    • (1994) Am J Cardiol , vol.74 , pp. 1278-1280
    • Mintz, G.S.1    Pichard, A.D.2    Kent, K.M.3
  • 22
    • 0026592026 scopus 로고
    • The importance of acute luminal diameter in determining restenosis after coronary atherectomy or stenting
    • Kuntz RE, Safian RD, Carroza JP, et al. The importance of acute luminal diameter in determining restenosis after coronary atherectomy or stenting. Circulation 1992;86: 1827-35.
    • (1992) Circulation , vol.86 , pp. 1827-1835
    • Kuntz, R.E.1    Safian, R.D.2    Carroza, J.P.3
  • 23
    • 0027166907 scopus 로고
    • Usefulness of quantitative and qualitative angiographic lesion morphology, and clinical characteristics in predicting major adverse cardiac events during and after native coronary balloon angioplasty
    • Hermans WRM, Foley DP, Rensing BJ, et al. Usefulness of quantitative and qualitative angiographic lesion morphology, and clinical characteristics in predicting major adverse cardiac events during and after native coronary balloon angioplasty. Am J Cardiol 1993;72:14-20.
    • (1993) Am J Cardiol , vol.72 , pp. 14-20
    • Hermans, W.R.M.1    Foley, D.P.2    Rensing, B.J.3
  • 24
    • 0027319235 scopus 로고
    • A comparison of directional atherectomy with coronary angioplasty in patients with coronary artery disease
    • Topol EJ, Leya F, Pinkerton CA, et al. for the CAVEAT Study Group. A comparison of directional atherectomy with coronary angioplasty in patients with coronary artery disease. N Engl J Med 1993;329:221-7.
    • (1993) N Engl J Med , vol.329 , pp. 221-227
    • Topol, E.J.1    Leya, F.2    Pinkerton, C.A.3
  • 25
    • 0028120873 scopus 로고
    • Formation of pressure waves during in vitro excimer laser irradiation in whole blood and the effect of dilution with contrast media and saline
    • Baumbach A, Haase KK, Rose C, et al. Formation of pressure waves during in vitro excimer laser irradiation in whole blood and the effect of dilution with contrast media and saline. Lasers Surg Med 1994;14:3-6
    • (1994) Lasers Surg Med , vol.14 , pp. 3-6
    • Baumbach, A.1    Haase, K.K.2    Rose, C.3
  • 26
    • 0026492336 scopus 로고
    • Effect of force on ablation depth for a XeCl excimer laser beam delivered by an optical fiber in contact with arterial tissue under saline
    • Gijsbers GHM, Van den Broecke DG, Sprangers RLH, et al. Effect of force on ablation depth for a XeCl excimer laser beam delivered by an optical fiber in contact with arterial tissue under saline. Lasers Surg Med 1992;12:576-84.
    • (1992) Lasers Surg Med , vol.12 , pp. 576-584
    • Gijsbers, G.H.M.1    Van Den Broecke, D.G.2    Sprangers, R.L.H.3
  • 27
    • 0030030235 scopus 로고    scopus 로고
    • Tissue ablation and gas formation of two excimer laser systems: An in vitro evaluation on porcine aorta
    • Appelman YEA, Pick JJ, Verhoofstad GGAM, et al. Tissue ablation and gas formation of two excimer laser systems: an in vitro evaluation on porcine aorta. Lasers Surg Med 1996; 18:197-205.
    • (1996) Lasers Surg Med , vol.18 , pp. 197-205
    • Appelman, Y.E.A.1    Pick, J.J.2    Verhoofstad, G.G.A.M.3
  • 28
    • 0028358149 scopus 로고
    • Initial clinical experience with a modified excimer laser for coronary angioplasty
    • Haase KK, Baumbach A, Spyridopoulos K, et al. Initial clinical experience with a modified excimer laser for coronary angioplasty. Lasers Med Sci 1994;9:7-15.
    • (1994) Lasers Med Sci , vol.9 , pp. 7-15
    • Haase, K.K.1    Baumbach, A.2    Spyridopoulos, K.3
  • 29
    • 7144265796 scopus 로고
    • 308nm excimer laser tissue interaction using a modified multifiber catheter
    • Hamburger JN, Gijsbers GHM, Lijmer JG, et al. 308nm excimer laser tissue interaction using a modified multifiber catheter [abstract]. J Am Coll Cardiol 1993; 21:385.
    • (1993) J Am Coll Cardiol , vol.21 , pp. 385
    • Hamburger, J.N.1    Gijsbers, G.H.M.2    Lijmer, J.G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.