메뉴 건너뛰기




Volumn , Issue , 2009, Pages 1051-1054

Condition monitoring of power transformer: A field experience

Author keywords

Partial discharge measurement; Power transformer; Vibration analysis

Indexed keywords

FIELD EXPERIENCE; INTEGRATED CONDITION MONITORING; MEASUREMENT RESULTS; PARTIAL DISCHARGE MEASUREMENT; PARTIAL DISCHARGE MEASUREMENTS; POWER FREQUENCY;

EID: 71049139843     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ICPADM.2009.5252448     Document Type: Conference Paper
Times cited : (3)

References (10)
  • 1
    • 71049122886 scopus 로고    scopus 로고
    • Recent technology development on partial discharge measurement in diagnosis for GIS, transformers, cables and inverter-fed motors
    • Bandung, November
    • M. Hikita, "Recent Technology Development on Partial Discharge Measurement in Diagnosis for GIS, Transformers, Cables and Inverter-fed Motors", Proc. of the 14th Asian Conference on Electrical Discharge, Bandung, pp. 1-8, November 2008.
    • (2008) th Asian Conference on Electrical Discharge , pp. 1-8
    • Hikita, M.1
  • 4
    • 71049117313 scopus 로고    scopus 로고
    • Structure-vibration analysis of a power transformer: 154kV/60MVA/single phase
    • February
    • Y-D Kim, et aI., "Structure-Vibration Analysis of a Power Transformer: 154kV/60MVA/Single Phase", Proc. of World Academy of Science, Engineering and Technology, Vol. 38, pp.106-110, February 2009.
    • (2009) Proc. of World Academy of Science, Engineering and Technology , vol.38 , pp. 106-110
    • Kim, Y.-D.1
  • 5
    • 0026887276 scopus 로고
    • Partial discharge - Part XIII: Acoustic partial discharge detection fundamental considerations
    • July/August
    • L. E. Lundgaard, "Partial Discharge - Part XIII: Acoustic Partial Discharge Detection Fundamental Considerations", IEEE Electrical Insulation Magazine, Vol. 8, No.4, pp. 25-31, July/August 1992.
    • (1992) IEEE Electrical Insulation Magazine , vol.8 , Issue.4 , pp. 25-31
    • Lundgaard, L.E.1
  • 6
    • 84945715370 scopus 로고
    • Partial discharge - part XIV: Acoustic partial discharge detection - practical application
    • September/October
    • L. E. Lundgaard, "Partial Discharge - Part XIV: Acoustic Partial Discharge Detection - Practical Application", IEEE Electrical Insulation Magazine, Vol. 8, No.5, pp. 34-43, September/October 1992.
    • (1992) IEEE Electrical Insulation Magazine , vol.8 , Issue.5 , pp. 34-43
    • Lundgaard, L.E.1
  • 7
    • 0029405006 scopus 로고
    • Partial discharge XXI: Acoustic emission-based PD source location in transformer
    • November/December
    • P. M. Eleftherion, "Partial Discharge XXI: Acoustic Emission-Based PD Source Location in Transformer", IEEE Electrical Insulation Magazine, Vol. 11, No.6, pp. 22-26, November/December 1995.
    • (1995) IEEE Electrical Insulation Magazine , vol.11 , Issue.6 , pp. 22-26
    • Eleftherion, P.M.1
  • 8
    • 0032312161 scopus 로고    scopus 로고
    • On-line partial discharge measurement on instrument transformers
    • Toyohashi, Paper No. D2-2, September
    • T. R. Blackburn, et aI., "On-line Partial Discharge Measurement on Instrument Transformers", International Symposium on Electrical Insulating Materials, Toyohashi, Paper No. D2-2, pp. 497-500, September 1998.
    • (1998) International Symposium on Electrical Insulating Materials , pp. 497-500
    • Blackburn, T.R.1
  • 9
    • 0008602497 scopus 로고    scopus 로고
    • On-line partial discharge measurement on high voltage power cables
    • London, August
    • B. T. Phung, et al., "On-line Partial Discharge Measurement on High Voltage Power Cables", 11th International Symposium on High Voltage Engineering (ISH), London, Vol. 4, pp. 328 -332, August 1999.
    • (1999) 11th International Symposium on High Voltage Engineering (ISH) , vol.4 , pp. 328-332
    • Phung, B.T.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.