1
-
-
71049122886
-
Recent technology development on partial discharge measurement in diagnosis for GIS, transformers, cables and inverter-fed motors
-
Bandung, November
-
M. Hikita, "Recent Technology Development on Partial Discharge Measurement in Diagnosis for GIS, Transformers, Cables and Inverter-fed Motors", Proc. of the 14th Asian Conference on Electrical Discharge, Bandung, pp. 1-8, November 2008.
-
(2008)
th Asian Conference on Electrical Discharge
, pp. 1-8
-
-
Hikita, M.1
-
2
-
-
78651442064
-
Transformer diagnostics: Common used and new methods
-
Changwon, April
-
G. J. Pukel, H. M. Muhr, W. Lick, "Transformer Diagnostics: Common Used and New Methods", Proc. of International Conference on Condition Monitoring and Diagnosis, Changwon, April 2006.
-
(2006)
Proc. of International Conference on Condition Monitoring and Diagnosis
-
-
Pukel, G.J.1
Muhr, H.M.2
Lick, W.3
-
3
-
-
71049130805
-
-
PT PLN (Persero) Transmission and Load Dispatch Centre
-
R. Siregar, "Vibration Monitoring Report: Transformer 1, 150/20kV, 60MVA, Gianyar Substation", PT PLN (Persero) Transmission and Load Dispatch Centre, 2008 (in Indonesian).
-
(2008)
Vibration Monitoring Report: Transformer 1, 150/20kV, 60MVA, Gianyar Substation, in Indonesian
-
-
Siregar, R.1
-
4
-
-
71049117313
-
Structure-vibration analysis of a power transformer: 154kV/60MVA/single phase
-
February
-
Y-D Kim, et aI., "Structure-Vibration Analysis of a Power Transformer: 154kV/60MVA/Single Phase", Proc. of World Academy of Science, Engineering and Technology, Vol. 38, pp.106-110, February 2009.
-
(2009)
Proc. of World Academy of Science, Engineering and Technology
, vol.38
, pp. 106-110
-
-
Kim, Y.-D.1
-
5
-
-
0026887276
-
Partial discharge - Part XIII: Acoustic partial discharge detection fundamental considerations
-
July/August
-
L. E. Lundgaard, "Partial Discharge - Part XIII: Acoustic Partial Discharge Detection Fundamental Considerations", IEEE Electrical Insulation Magazine, Vol. 8, No.4, pp. 25-31, July/August 1992.
-
(1992)
IEEE Electrical Insulation Magazine
, vol.8
, Issue.4
, pp. 25-31
-
-
Lundgaard, L.E.1
-
6
-
-
84945715370
-
Partial discharge - part XIV: Acoustic partial discharge detection - practical application
-
September/October
-
L. E. Lundgaard, "Partial Discharge - Part XIV: Acoustic Partial Discharge Detection - Practical Application", IEEE Electrical Insulation Magazine, Vol. 8, No.5, pp. 34-43, September/October 1992.
-
(1992)
IEEE Electrical Insulation Magazine
, vol.8
, Issue.5
, pp. 34-43
-
-
Lundgaard, L.E.1
-
7
-
-
0029405006
-
Partial discharge XXI: Acoustic emission-based PD source location in transformer
-
November/December
-
P. M. Eleftherion, "Partial Discharge XXI: Acoustic Emission-Based PD Source Location in Transformer", IEEE Electrical Insulation Magazine, Vol. 11, No.6, pp. 22-26, November/December 1995.
-
(1995)
IEEE Electrical Insulation Magazine
, vol.11
, Issue.6
, pp. 22-26
-
-
Eleftherion, P.M.1
-
8
-
-
0032312161
-
On-line partial discharge measurement on instrument transformers
-
Toyohashi, Paper No. D2-2, September
-
T. R. Blackburn, et aI., "On-line Partial Discharge Measurement on Instrument Transformers", International Symposium on Electrical Insulating Materials, Toyohashi, Paper No. D2-2, pp. 497-500, September 1998.
-
(1998)
International Symposium on Electrical Insulating Materials
, pp. 497-500
-
-
Blackburn, T.R.1
-
9
-
-
0008602497
-
On-line partial discharge measurement on high voltage power cables
-
London, August
-
B. T. Phung, et al., "On-line Partial Discharge Measurement on High Voltage Power Cables", 11th International Symposium on High Voltage Engineering (ISH), London, Vol. 4, pp. 328 -332, August 1999.
-
(1999)
11th International Symposium on High Voltage Engineering (ISH)
, vol.4
, pp. 328-332
-
-
Phung, B.T.1
-
10
-
-
71049143629
-
-
PT PLN (Persero) Transmission and Load Dispatch Centre
-
I. K. Solin, "Partial Discharge Monitoring Report: Transformer 1, 150/20kV, 60MVA, Gianyar Substation", PT PLN (Persero) Transmission and Load Dispatch Centre, 2008 (in Indonesian).
-
(2008)
Partial Discharge Monitoring Report: Transformer 1, 150/20kV, 60MVA, Gianyar Substation, in Indonesian
-
-
Solin, I.K.1
|