메뉴 건너뛰기




Volumn , Issue , 2009, Pages 196-199

Study on the effect of different internal corona protection on electrical properties of generator stator bar

Author keywords

Electrical properties; Internal corona protection; Stator bar

Indexed keywords

BREAKDOWN VOLTAGE; CORONA PROTECTION; DIELECTRIC LOSS FACTORS; DIFFERENT STRUCTURE; ELECTRICAL PROPERTIES; ELECTRICAL PROPERTY; GENERATOR STATORS; INTERNAL CORONA PROTECTION; LARGE GENERATOR; LOSS FACTOR; PARTIAL DISCHARGE MAGNITUDES; SHIELD LAYERS; STATOR BAR;

EID: 71049138133     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ICPADM.2009.5252474     Document Type: Conference Paper
Times cited : (3)

References (5)
  • 1
    • 71049159665 scopus 로고    scopus 로고
    • Study on structure test of generator stator bars conductor
    • L. Qi, Z. Liang and R. Pi, "Study on Structure Test of Generator Stator Bars Conductor" in Insulation Material, pp 19-24, No.3, 2005.
    • (2005) Insulation Material , Issue.3 , pp. 19-24
    • Qi, L.1    Liang, Z.2    Pi, R.3
  • 2
    • 4644232852 scopus 로고    scopus 로고
    • Study on the aging character- -istics of stator winding insulation in large generator based on operating history
    • Aug.
    • B. Zhang, N. Gao, X. Ma and H. Xie, "Study on the Aging Character- -istics of Stator Winding Insulation in Large Generator Based on Operating History" in Proceedings of the CSEE, pp 134-137, Vol.24 No.8 Aug. 2004.
    • (2004) Proceedings of the CSEE , vol.24 , Issue.8 , pp. 134-137
    • Zhang, B.1    Gao, N.2    Ma, X.3    Xie, H.4
  • 3
    • 71049181498 scopus 로고    scopus 로고
    • Electric field distribution improving of high-voltage electric machine stator coils
    • Y. Sui, L. Fu, "Electric Field Distribution Improving of High-voltage Electric Machine Stator Coils" in large electrical machine technology, pp 22-25, no2, 2001.
    • (2001) Large Electrical Machine Technology , Issue.2 , pp. 22-25
    • Sui, Y.1    Fu, L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.