메뉴 건너뛰기




Volumn 54, Issue 11, 2009, Pages 1480-1487

Laboratory evaluation of the Acapella device: Pressure characteristics under different conditions, and a software tool to optimize its practical use

Author keywords

Acapella; Bronchial hygiene; Chest physiotherapy; High frequency oscillation; Oscillatory positive expiratory pressure; Positive expiratory pressure; Secretion clearance; Software

Indexed keywords

AIRFLOW; AMPLITUDE MODULATION; ARTICLE; COMPUTER PROGRAM; EVALUATION; FLOW RATE; MEDICAL INSTRUMENTATION; OSCILLATION; PRESSURE;

EID: 70849119155     PISSN: 00201324     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (14)

References (20)
  • 2
    • 22144476239 scopus 로고    scopus 로고
    • Airway clearance in bronchiectasis: A randomized crossover trial of active cycle of breathing techniques versus Acapella
    • DOI 10.1159/000085363
    • Patterson JE, Bradley JM, Hewitt O, Bradbury I. Airway clearance in bronchiectasis:Arandomized crossover trial of active cycle of breathing techniques versus Acapella. Respiration 2005;(72):239-242. (Pubitemid 40981081)
    • (2005) Respiration , vol.72 , Issue.3 , pp. 239-242
    • Patterson, J.E.1    Bradley, J.M.2    Hewitt, O.3    Bradbury, I.4    Elborn, J.S.5
  • 3
    • 0038048933 scopus 로고    scopus 로고
    • Performance comparison of two oscillating positive expiratory pressure devices: Acapella versus flutter
    • Volsko TA, DiFiore J, Chatburn RL. Performance comparison of 2 oscillating positive expiratory pressure devices: Acapella vs Flutter. Respir Care 2003;48(2):124-130. (Pubitemid 47372063)
    • (2004) Respiratory Care , vol.48 , Issue.2 , pp. 124-130
    • Volsko, T.A.1    Difiore, J.M.2    Chatburn, R.L.3
  • 4
    • 44449164647 scopus 로고    scopus 로고
    • The value of conducting laboratory investigations on airway clearance devices
    • Volsko TA. The value of conducting laboratory investigations on airway clearance devices. Respir Care 2008;53(3):311-313.
    • (2008) Respir Care , vol.53 , Issue.3 , pp. 311-313
    • Volsko, T.A.1
  • 5
    • 44449166265 scopus 로고    scopus 로고
    • Performance analysis of the Flutter VRP1 under different flows and angles
    • Alves LA, Pitta F, Brunetto AF. Performance analysis of the Flutter VRP1 under different flows and angles. Respir Care 2008;53(3):316-323.
    • (2008) Respir Care , vol.53 , Issue.3 , pp. 316-323
    • Alves, L.A.1    Pitta, F.2    Brunetto, A.F.3
  • 6
    • 84902148402 scopus 로고    scopus 로고
    • Otimização do uso do Flutter VRP1 em reabilitaç ão respiratória: Caracterização mecânica e desenvolvimento de programas de apoio ao usuário
    • Article in Portugese
    • Alves CE, Santos JG, Melo PL. [Otimização do uso do Flutter VRP1 em reabilitação respiratória: Caracterizaç ão mecânica e desenvolvimento de programas de apoio ao usuário]. Annals of the IV Latin American Congress on Biomedical Engineering 2007;1020-1023. Article in Portugese.
    • (2007) Annals of the IV Latin American Congress on Biomedical Engineering , pp. 1020-1023
    • Alves, C.E.1    Santos, J.G.2    Melo, P.L.3
  • 7
    • 70849130851 scopus 로고    scopus 로고
    • Caracterização mecânica de um dispositivo de pressão expiratória positiva oscilante utilizado em reabilitação respiratória
    • Article in Portugese
    • Alves CE, Santos JG, Melo PL. [Caracterização mecânica de um dispositivo de pressão expiratória positiva oscilante utilizado em reabilitação respiratória]. Brazilian Congress on Biomedical Engineering 2006;1071-1074. Article in Portugese
    • (2006) Brazilian Congress on Biomedical Engineering , pp. 1071-1074
    • Alves, C.E.1    Santos, J.G.2    Melo, P.L.3
  • 8
    • 33750724103 scopus 로고    scopus 로고
    • Physiological effects of vibration in subjects with cystic fibrosis
    • DOI 10.1183/09031936.06.00083605
    • McCarren B, Alison JA. Physiological effects of vibration in subjects with cystic fibrosis. Eur Respir J 2006;27(6):1204-1209. (Pubitemid 44914305)
    • (2006) European Respiratory Journal , vol.27 , Issue.6 , pp. 1204-1209
    • McCarren, B.1    Alison, J.A.2
  • 9
    • 34547215727 scopus 로고    scopus 로고
    • Acapella versus 'usual airway clearance' during exacerbation in bronchiectasis: A randomized crossover trial
    • Patterson JE, Hewitt O, Kent L, Bradbury I, Elborn JS, and Bradley JM. Acapella versus 'usual airway clearance' during exacerbation in bronchiectasis: a randomized crossover trial. Chron Respir Dis 2007; (4):67-74.
    • (2007) Chron Respir Dis , Issue.4 , pp. 67-74
    • Patterson, J.E.1    Hewitt, O.2    Kent, L.3    Bradbury, I.4    Elborn, J.S.5    Bradley, J.M.6
  • 11
    • 2542462026 scopus 로고    scopus 로고
    • Physiologic evidence for the efficacy of positive expiratory pressure as an airway clearance technique in patients with cystic fibrosis
    • Darbee JC, Ohtake PJ, Grant BJB, Cerny FJ. Physiologic evidence for the efficacy of positive expiratory pressure as an airway clearance technique in patients with cystic fibrosis. Phys Ther 2004;84(6):524-537.
    • (2004) Phys Ther , vol.84 , Issue.6 , pp. 524-537
    • Darbee, J.C.1    Ohtake, P.J.2    Grant, B.J.B.3    Cerny, F.J.4
  • 14
    • 70849134773 scopus 로고
    • Particle deposition and mucociliary clearance: Physical signs
    • Bates DV, editor. Philadelphia: WB Saunders
    • King M. Particle deposition and mucociliary clearance: physical signs. In: Bates DV, editor. Respiratory function in disease. Philadelphia: WB Saunders; 1988:67-80.
    • (1988) Respiratory Function in Disease , pp. 67-80
    • King, M.1
  • 15
    • 0027948164 scopus 로고
    • Effects of oscillating air flow on the rheological properties and clearability of mucous gel simulants
    • Tomkiewicz RP, Biviji AA, King M. Effects of oscillating air flow on the rheological properties and clearability of mucous gel simulants. Biorheology 1994;31(5):511-520. (Pubitemid 24339025)
    • (1994) Biorheology , vol.31 , Issue.5 , pp. 511-520
    • Tomkiewicz, R.P.1    Biviji, A.2    King, M.3
  • 16
    • 0023805101 scopus 로고
    • Mucus transport by high-frequency nonsymmetrical oscillatory airflow
    • Chang HG, Weber ME, King M. Mucus transport by high frequency nonsymmetrical oscillatory airflow. J Appl Physiol 1988;65(3):1203-1209. (Pubitemid 18224692)
    • (1988) Journal of Applied Physiology , vol.65 , Issue.3 , pp. 1203-1209
    • Chang, H.K.1    Weber, M.E.2    King, M.3
  • 17
    • 33750869770 scopus 로고    scopus 로고
    • Detection of changes in respiratory mechanics due to increasing degrees of airway obstruction in asthma by the forced oscillation technique
    • DOI 10.1016/j.rmed.2006.03.009, PII S0954611106001247
    • Cavalcanti JV, Lopes AJ, Jansen JM, Melo PL. Detection of changes in respiratory mechanics due to increasing degrees of airway obstruction in asthma by the forced oscillation technique. Respir Med 2006;100(12):2207-2219. (Pubitemid 44718387)
    • (2006) Respiratory Medicine , vol.100 , Issue.12 , pp. 2207-2219
    • Cavalcanti, J.V.1    Lopes, A.J.2    Jansen, J.M.3    Melo, P.L.4
  • 18
    • 32644432877 scopus 로고    scopus 로고
    • Changes in respiratory mechanics with increasing degrees of airway obstruction in COPD: Detection by forced oscillation technique
    • DOI 10.1016/j.rmed.2005.07.005, PII S0954611105002726
    • DiMango AMGT, Lopes AJ, Jansen MJ, Melo PL. Changes in respiratory mechanics with increasing degrees of airway obstruction in COPD: detection by forced oscillation technique. Respir Med 2006; 100:399-410. (Pubitemid 43239874)
    • (2006) Respiratory Medicine , vol.100 , Issue.3 , pp. 399-410
    • Di Mango, A.M.G.T.1    Lopes, A.J.2    Jansen, J.M.3    Melo, P.L.4
  • 19
    • 16644398735 scopus 로고    scopus 로고
    • Expanding opportunities for handheld technology use in respiratory care
    • Volsko TA. Expanding opportunities for handheld technology use in respiratory care. Respir Care 2004;49(11):1307-1308.
    • (2004) Respir Care , vol.49 , Issue.11 , pp. 1307-1308
    • Volsko, T.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.