메뉴 건너뛰기




Volumn 9, Issue 11, 2009, Pages 9073-9093

Implantable CMOS biomedical devices

Author keywords

Biomedical devices; Brain implantation; CMOS; Image sensors; Retinal prosthesis

Indexed keywords

BIOMEDICAL DEVICES; IN-VIVO EXPERIMENTS; RECENT RESEARCHES; RETINAL PROSTHESIS; SMALL ANIMAL;

EID: 70849117434     PISSN: 14248220     EISSN: None     Source Type: Journal    
DOI: 10.3390/s91109073     Document Type: Review
Times cited : (85)

References (36)
  • 1
    • 22844434279 scopus 로고    scopus 로고
    • Flexible and extendible neural interface device based on cooperative multi-chip CMOS LSI architecture
    • Tokuda, T.; Pan, Y.-L.; Uehara, A.; Kagawa, K.; Nunoshita, M.; Ohta, J. Flexible and extendible neural interface device based on cooperative multi-chip CMOS LSI architecture. Sens. Actuat. A 2005, 122, 88-98.
    • (2005) Sens. Actuat. A , vol.122 , pp. 88-98
    • Tokuda, T.1    Pan, Y.-L.2    Uehara, A.3    Kagawa, K.4    Nunoshita, M.5    Ohta, J.6
  • 6
    • 33747155075 scopus 로고    scopus 로고
    • Real time in vivo imaging and measurement of serine protease activity in the mouse hippocampus using a dedicated CMOS imaging device
    • Ng, D.C.; Tamura, H.; Tokuda, T.; Yamamoto, A.; Matsuo, M.; Nunoshita, M.; Ishikawa, Y.; Shiosaka, S.; Ohta, J. Real time in vivo imaging and measurement of serine protease activity in the mouse hippocampus using a dedicated CMOS imaging device. J. Neurosci. Meth. 2006, 156, 2006.
    • (2006) J. Neurosci. Meth , vol.2006 , pp. 156
    • Ng, D.C.1    Tamura, H.2    Tokuda, T.3    Yamamoto, A.4    Matsuo, M.5    Nunoshita, M.6    Ishikawa, Y.7    Shiosaka, S.8    Ohta, J.9
  • 7
    • 44849141108 scopus 로고    scopus 로고
    • An implantable and fully-integrated complementary metal-oxide semiconductor device for in vivo neural imaging and electrical interfacing with the mouse hippocampus
    • Ng, D.C.; Tamura, H.; Mizuno, T.; Tokuda, T.; Nunoshita, M.; Ishikawa, Y.; Shiosaka, S.; Ohta, J. An implantable and fully-integrated complementary metal-oxide semiconductor device for in vivo neural imaging and electrical interfacing with the mouse hippocampus. Sens. Actuat. A 2008, 145-146, 176-186.
    • (2008) Sens. Actuat. A
    • Ng, D.C.1    Tamura, H.2    Mizuno, T.3    Tokuda, T.4    Nunoshita, M.5    Ishikawa, Y.6    Shiosaka, S.7    Ohta, J.8
  • 9
    • 54049119184 scopus 로고    scopus 로고
    • One-chip sensing device (Biomedical photonic LSI) enabled to assess hippocampal steep and gradual up-regulated proteolytic activities
    • Tamura, H.; Ng, D.C.; Tokuda, T.; Naoki, T.; Nakagawa, T.; Mizuno, T.; Hatanaka, Y.; Ishikawa, Y.; Ohta, J.; Shiosaka, S. One-chip sensing device (Biomedical photonic LSI) enabled to assess hippocampal steep and gradual up-regulated proteolytic activities. J. Neurosci. Meth. 2008, 173, 114-120.
    • (2008) J. Neurosci. Meth , vol.173 , pp. 114-120
    • Tamura, H.1    Ng, D.C.2    Tokuda, T.3    Naoki, T.4    Nakagawa, T.5    Mizuno, T.6    Hatanaka, Y.7    Ishikawa, Y.8    Ohta, J.9    Shiosaka, S.10
  • 11
    • 0002857874 scopus 로고
    • Effects of Prolonged Electrical Stimulation of the Central Nervous System
    • In, Prentice Hall: Englewood Cliffs, NJ, USA
    • Agnew, W.F.; McCreery, D.B.; Yuen, T.G.H.; Bullara, L.A. Effects of Prolonged Electrical Stimulation of the Central Nervous System. In Neural Prostheses; Prentice Hall: Englewood Cliffs, NJ, USA, 1990.
    • (1990) Neural Prostheses
    • Agnew, W.F.1    McCreery, D.B.2    Yuen, T.G.H.3    Bullara, L.A.4
  • 12
    • 0002027562 scopus 로고
    • Electrochemical Guidelines for Selection of Protocols and Electrode Materials for Neural Stimulation
    • In, Prentice Hall: Englewood Cliffs, NJ, USA
    • Robblee, L.S.; Rose, T.L. Electrochemical Guidelines for Selection of Protocols and Electrode Materials for Neural Stimulation. In Neural Prostheses; Prentice Hall: Englewood Cliffs, NJ, USA, 1990.
    • (1990) Neural Prostheses
    • Robblee, L.S.1    Rose, T.L.2
  • 13
    • 0003011402 scopus 로고
    • Mechanics of Stimulation-Induced Neural Damage and Their Relation to Guidelines for Safe Stimulation
    • In, Prentice Hall: Englewood Cliffs, NJ, USA
    • McCreery, D.B.; Agnew, W.F. Mechanics of Stimulation-Induced Neural Damage and Their Relation to Guidelines for Safe Stimulation. In Neural Prostheses; Prentice Hall: Englewood Cliffs, NJ, USA, 1990.
    • (1990) Neural Prostheses
    • McCreery, D.B.1    Agnew, W.F.2
  • 14
    • 0003953928 scopus 로고
    • Sinauer Associates Inc.: Sunderland, MA, USA
    • Wandell, B.A. Foundations of Vision; Sinauer Associates Inc.: Sunderland, MA, USA, 1995.
    • (1995) Foundations of Vision
    • Wandell, B.A.1
  • 15
    • 70849130189 scopus 로고    scopus 로고
    • Research Report by Ministry of Health, Labour, and Welfare of Japan
    • Research Report by Ministry of Health, Labour, and Welfare of Japan, 2005.
    • (2005)
  • 20
    • 0345014794 scopus 로고    scopus 로고
    • Methods and perceptual thresholds for short-term electrical stimulation of human retina with microelectrode Arrays
    • Rizzo, J.F., III; Wyatt, J.; Loewenstein, J.; Kelly, S.; Shire, D. Methods and perceptual thresholds for short-term electrical stimulation of human retina with microelectrode Arrays. Invest. Ophthalmol. Vis. Sci. 2003, 44, 5355-5361.
    • (2003) Invest. Ophthalmol. Vis. Sci , vol.44 , pp. 5355-5361
    • Rizzo III, J.F.1    Wyatt, J.2    Loewenstein, J.3    Kelly, S.4    Shire, D.5
  • 22
    • 1842582778 scopus 로고    scopus 로고
    • The artificial silicon retina microchip for the treatment of vision loss from retinitis pigmentosa. Arch
    • Chow, A.Y.; Chow, V.Y.; Packo, K.; Pollack, J.; Peyman, G.; Schuchard, R. The artificial silicon retina microchip for the treatment of vision loss from retinitis pigmentosa. Arch. Ophthalmol. 2004, 122, 460-469.
    • (2004) Ophthalmol , vol.122 , pp. 460-469
    • Chow, A.Y.1    Chow, V.Y.2    Packo, K.3    Pollack, J.4    Peyman, G.5    Schuchard, R.6
  • 23
    • 0037039812 scopus 로고    scopus 로고
    • Will retinal implants restore vision?
    • Zrenner, E. Will retinal implants restore vision? Science 2002, 295, 1022-1025.
    • (2002) Science , vol.295 , pp. 1022-1025
    • Zrenner, E.1
  • 25
    • 0942287247 scopus 로고    scopus 로고
    • Electrophysiological studies of the feasibility of suprachoroidal-transretinal stimulation for artificial vision in normal and RCS rats
    • Kanda, H.; Morimoto, T.; Fujikado, T.; Tano, Y.; Fukuda, Y.; Sawai, H. Electrophysiological studies of the feasibility of suprachoroidal-transretinal stimulation for artificial vision in normal and RCS rats. Invest. Ophthal. Vis. Sci. 2004, 45, 560-566.
    • (2004) Invest. Ophthal. Vis. Sci , vol.45 , pp. 560-566
    • Kanda, H.1    Morimoto, T.2    Fujikado, T.3    Tano, Y.4    Fukuda, Y.5    Sawai, H.6
  • 28
    • 0033972960 scopus 로고    scopus 로고
    • Artificial vision for the blind by connecting a television camera to the visual cortex
    • Dobelle, W.H. Artificial vision for the blind by connecting a television camera to the visual cortex. ASAIO J. 2000, 46, 3-9.
    • (2000) ASAIO J , vol.46 , pp. 3-9
    • Dobelle, W.H.1
  • 30
    • 17644367244 scopus 로고    scopus 로고
    • Cochlear Implants
    • Kenneth, W.H., Dhilon, G.S., Eds.; World Scientific Publishing Co. Pte. Ltd.: Singapore
    • Seligman, P.M.; Shepherd, R.K. Cochlear Implants. In Neuroprothetics; Kenneth, W.H., Dhilon, G.S., Eds.; World Scientific Publishing Co. Pte. Ltd.: Singapore, 2004.
    • (2004) Neuroprothetics
    • Seligman, P.M.1    Shepherd, R.K.2
  • 32
    • 33646937857 scopus 로고    scopus 로고
    • Time and Space
    • In, 2nd ed.; Toga, A.W., Mazziota, J.C., Eds.; Academic Press: New York, NY, USA
    • Mazziota, J.C. Time and Space. In Brain Mapping the Methods, 2nd ed.; Toga, A.W., Mazziota, J.C., Eds.; Academic Press: New York, NY, USA, 2002; pp. 33-44.
    • (2002) Brain Mapping the Methods , pp. 33-44
    • Mazziota, J.C.1
  • 33
    • 0035959949 scopus 로고    scopus 로고
    • A miniature head-mounted neurotechnique two- photon microscope: High resolution brain imaging in freely moving animals
    • Helmchen, F.; Fee, M.S.; Tank, D.W.; Denk, W. A miniature head-mounted neurotechnique two- photon microscope: high resolution brain imaging in freely moving animals. Neuron 2001, 31, 903-912.
    • (2001) Neuron , vol.31 , pp. 903-912
    • Helmchen, F.1    Fee, M.S.2    Tank, D.W.3    Denk, W.4
  • 35
    • 33748295600 scopus 로고    scopus 로고
    • On-chip biofluorescence imaging inside a brain tissue phantom using a CMOS image sensor for in vivo brain imaging verification
    • Ng, D.C.; Tokuda, T.; Yamamoto, A.: Matsuo, M.: Nunoshita, M.; Tamura, H.; Ishikawa, Y.; Shiosaka, S.; Ohta, J. On-chip biofluorescence imaging inside a brain tissue phantom using a CMOS image sensor for in vivo brain imaging verification, Sens. Actuat. B 2006, 119, 262-274.
    • (2006) Sens. Actuat. B , vol.119 , pp. 262-274
    • Ng, D.C.1    Tokuda, T.2    Yamamoto, A.3    Matsuo, M.4    Nunoshita, M.5    Tamura, H.6    Ishikawa, Y.7    Shiosaka, S.8    Ohta, J.9
  • 36
    • 70849084090 scopus 로고    scopus 로고
    • Development of complementary metal oxide semiconductor imaging devices for detecting green fluorescent protein in the deep brain of a freely moving mouse
    • 04C195-1-5
    • Tagawa, A.; Higuchi, A.; Sugiyama, T.; Sasagawa, K.; Tokuda, T.; Tamura, H.; Hatanaka, Y.; Shiosaka, S.; Ohta, J. Development of complementary metal oxide semiconductor imaging devices for detecting green fluorescent protein in the deep brain of a freely moving mouse. Jpn. J. Appl. Phys. 2009, 48, 04C195-1-5.
    • (2009) Jpn. J. Appl. Phys , vol.48
    • Tagawa, A.1    Higuchi, A.2    Sugiyama, T.3    Sasagawa, K.4    Tokuda, T.5    Tamura, H.6    Hatanaka, Y.7    Shiosaka, S.8    Ohta, J.9


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.