메뉴 건너뛰기




Volumn 8, Issue 3, 2009, Pages 251-264

A simulation study on the reduction of cooling loads in a detached house by cross-ventilation using the local dynamic similarity model

Author keywords

COMIS; Cooling load; Cross ventilation; Detached house; Energy saving; Local Dynamic Similarity model; TRNSYS; Ventilation path

Indexed keywords

AIR CONDITIONING; ENERGY CONSERVATION; HOUSES; VENTILATION;

EID: 70749161277     PISSN: 14733315     EISSN: None     Source Type: Journal    
DOI: 10.1080/14733315.2009.11683850     Document Type: Conference Paper
Times cited : (3)

References (11)
  • 1
    • 0019565685 scopus 로고
    • A simple omnidirectional sensor for wind-tunnel studies of pedestrian-level winds
    • Irwin HPAH: (1981) "A simple omnidirectional sensor for wind-tunnel studies of pedestrian-level winds", Journal of Wind Engineering and Industrial Aerodynamics, 7, pp219-239.
    • (1981) Journal of Wind Engineering and Industrial Aerodynamics , vol.7 , pp. 219-239
    • Irwin, H.P.A.H.1
  • 3
    • 33748787811 scopus 로고    scopus 로고
    • Kurabuchi T, Ohba M, Goto T, Akamine Y, Endo T and Kamata M: (2005) Local dynamic similarity concept as applied to the evaluation of discharge coefficients of cross ventilated buildings, Part 1 Basic idea and underlying wind tunnel tests; Part 2 Applicability of local dynamic similarity model; Part 3 Simplified method for estimating dynamic pressure tangential to openings of cross-ventilated buildings, The International Journal of Ventilation, 4, (3), pp285-300.
    • Kurabuchi T, Ohba M, Goto T, Akamine Y, Endo T and Kamata M: (2005) "Local dynamic similarity concept as applied to the evaluation of discharge coefficients of cross ventilated buildings, Part 1 Basic idea and underlying wind tunnel tests; Part 2 Applicability of local dynamic similarity model; Part 3 Simplified method for estimating dynamic pressure tangential to openings of cross-ventilated buildings", The International Journal of Ventilation, 4, (3), pp285-300.
  • 4
    • 33748767362 scopus 로고    scopus 로고
    • Windows and HVAC operation to reduce cooling requirement by means of cross-ventilation
    • Nagai T: (2006). "Windows and HVAC operation to reduce cooling requirement by means of cross-ventilation", The International Journal of Ventilation, 5, (1), pp151-162.
    • (2006) The International Journal of Ventilation , vol.5 , Issue.1 , pp. 151-162
    • Nagai, T.1
  • 6
    • 33748791178 scopus 로고    scopus 로고
    • Experimental study on predicting wind-driven cross-ventilation flow rates and discharge coefficients based on the Local dynamic similarity model
    • Ohba M, Goto T, Kurabuchi T et al.: (2006). "Experimental study on predicting wind-driven cross-ventilation flow rates and discharge coefficients based on the Local dynamic similarity model", The International Journal of Ventilation, 5, (1), pp105-114.
    • (2006) The International Journal of Ventilation , vol.5 , Issue.1 , pp. 105-114
    • Ohba, M.1    Goto, T.2    Kurabuchi, T.3
  • 7
    • 70749144634 scopus 로고    scopus 로고
    • Prediction accuracy of ventilation flow rates by COMIS model combined with local dynamic similarity model
    • in Japanese
    • Ohba M, Kurabuchi T, Goto T. et al: (2008a). "Prediction accuracy of ventilation flow rates by COMIS model combined with local dynamic similarity model", Annual meeting of AIJ, pp753-754 (in Japanese).
    • (2008) Annual meeting of AIJ , pp. 753-754
    • Ohba, M.1    Kurabuchi, T.2    Goto, T.3
  • 8
    • 70749138228 scopus 로고    scopus 로고
    • Study on prediction of ventilation flow rates in detached house based on coupled simulation of semi-empirical envelope flow model and network model
    • Korea, pp
    • Ohba M, Kurabuchi T, Goto T et al. (2008b). "Study on prediction of ventilation flow rates in detached house based on coupled simulation of semi-empirical envelope flow model and network model", Proceedings of 4th International Conference on Advances in Wind & Structures, Korea, pp1156-1166.
    • (2008) Proceedings of 4th International Conference on Advances in Wind & Structures , pp. 1156-1166
    • Ohba, M.1    Kurabuchi, T.2    Goto, T.3
  • 9
    • 85036791908 scopus 로고    scopus 로고
    • Tsukamoto K, Ohba M, Kurabuchi T et al: (2009). Study on reduction of cooling loads in detached house by cross-ventilation using coupled simulation of semi-empirical ventilation model and network models, Proceedings of the 11th International Conference on Air Distribution in Rooms, Korea, pp.VS3-1-VS3-6 (e-format).
    • Tsukamoto K, Ohba M, Kurabuchi T et al: (2009). "Study on reduction of cooling loads in detached house by cross-ventilation using coupled simulation of semi-empirical ventilation model and network models", Proceedings of the 11th International Conference on Air Distribution in Rooms, Korea, pp.VS3-1-VS3-6 (e-format).
  • 10
    • 22144487187 scopus 로고
    • Typical problems for house
    • AIJ in Japanese
    • Udagawa H: (1985). "Typical problems for house", 15th Heat Symposium, AIJ (in Japanese).
    • (1985) 15th Heat Symposium
    • Udagawa, H.1
  • 11
    • 0008618506 scopus 로고
    • External wind pressure distributions and induced internal ventilation flow in low-rise industrial and domestic structures
    • Vickery BJ and Karakatsanis C: (1987) "External wind pressure distributions and induced internal ventilation flow in low-rise industrial and domestic structures", ASHRAE Transactions, 93, Part 2, pp2198-2213.
    • (1987) ASHRAE Transactions , vol.93 , Issue.PART 2 , pp. 2198-2213
    • Vickery, B.J.1    Karakatsanis, C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.