1
-
-
0036620237
-
The novel Technique of delivering targeted intraoperative radiotherapy (Targit) for early breast cancer
-
Vaidya J.-S., Baum M., Tobias J.-S., Morgan S., and D'Souza D. The novel Technique of delivering targeted intraoperative radiotherapy (Targit) for early breast cancer. Eur J Surg Oncol 28 (2002) 447-454
-
(2002)
Eur J Surg Oncol
, vol.28
, pp. 447-454
-
-
Vaidya, J.-S.1
Baum, M.2
Tobias, J.-S.3
Morgan, S.4
D'Souza, D.5
-
2
-
-
34548803607
-
Accelerated partial breast irradiation: consensus statement of 3 German Oncology societies
-
Sauer R., Sautter-Bihl M.-L., Budach W., et al. Accelerated partial breast irradiation: consensus statement of 3 German Oncology societies. Cancer 110 (2007) 1187-1194
-
(2007)
Cancer
, vol.110
, pp. 1187-1194
-
-
Sauer, R.1
Sautter-Bihl, M.-L.2
Budach, W.3
-
3
-
-
35448958874
-
Intraoperative radiotherapy (IORT) is an option for patients with localized breast recurrences after previous external-beam radiotherapy
-
Kraus-Tiefenbacher U., Bauer L., Scheda A., et al. Intraoperative radiotherapy (IORT) is an option for patients with localized breast recurrences after previous external-beam radiotherapy. BMC-Cancer 7 (2007) 178
-
(2007)
BMC-Cancer
, vol.7
, pp. 178
-
-
Kraus-Tiefenbacher, U.1
Bauer, L.2
Scheda, A.3
-
4
-
-
33646549311
-
A dosimetric comparison of IORT techniques in limited-stage breast cancer
-
Nairz O., Deutschmann H., Kopp M., et al. A dosimetric comparison of IORT techniques in limited-stage breast cancer. Strahlenther Onkol 182 (2006) 342-348
-
(2006)
Strahlenther Onkol
, vol.182
, pp. 342-348
-
-
Nairz, O.1
Deutschmann, H.2
Kopp, M.3
-
6
-
-
12844251853
-
Radiobiological Aspects of Intraoperative Radiotherapy (IORT) with Isotropic Low-Energy X-rays for Early-Stage Breast Cancer
-
Herskind C., Steil V., Kraus-Tiefenbacher U., et al. Radiobiological Aspects of Intraoperative Radiotherapy (IORT) with Isotropic Low-Energy X-rays for Early-Stage Breast Cancer. Radiat Res 163 (2005) 208-215
-
(2005)
Radiat Res
, vol.163
, pp. 208-215
-
-
Herskind, C.1
Steil, V.2
Kraus-Tiefenbacher, U.3
-
7
-
-
70749099146
-
-
Richtlinie zur Durchführung der Qualitätssicherung bei Röntgeneinrichtungen zur Untersuchung oder Behandlung von Menschen nach den §§16 und 17 der Röntgenverordnung-Qualitätssicherungs-Richtlinie QS-RL, Gemeinsamen Ministerialblatt 2003;783
-
Richtlinie zur Durchführung der Qualitätssicherung bei Röntgeneinrichtungen zur Untersuchung oder Behandlung von Menschen nach den §§16 und 17 der Röntgenverordnung-Qualitätssicherungs-Richtlinie (QS-RL). Gemeinsamen Ministerialblatt 2003;783.
-
-
-
-
8
-
-
70749159435
-
-
Bekanntmachung einer Empfehlung der Strahlenschutzkommission Strahlenschutz in der Röntgentherapie Vom 18. Mai 2006 (BAnz. Nr. 108 vom 10.06.2006 S. 4325) 〈http://www.umwelt-online.de/regelwerk/energie/strahlen/roen_ges.htm〉.
-
Bekanntmachung einer Empfehlung der Strahlenschutzkommission "Strahlenschutz in der Röntgentherapie" Vom 18. Mai 2006 (BAnz. Nr. 108 vom 10.06.2006 S. 4325) 〈http://www.umwelt-online.de/regelwerk/energie/strahlen/roen_ges.htm〉.
-
-
-
-
9
-
-
70749087803
-
-
Peinsippl N, Roos G, Weimer G. Röntgenverordnung RöV Heidelberg Forkel Verlag; 2006.
-
Peinsippl N, Roos G, Weimer G. Röntgenverordnung RöV Heidelberg Forkel Verlag; 2006.
-
-
-
-
10
-
-
0141631862
-
Dosimetric characteristics of a low-kV intra-operative X-ray source: Implications for use in a clinical trial for treatment of low-risk breast cancer
-
Ebert M.-A., and Carutthers B. Dosimetric characteristics of a low-kV intra-operative X-ray source: Implications for use in a clinical trial for treatment of low-risk breast cancer. Med Phys 30 (2003) 2424-2431
-
(2003)
Med Phys
, vol.30
, pp. 2424-2431
-
-
Ebert, M.-A.1
Carutthers, B.2
-
11
-
-
34248389242
-
Functional intercomparison of intrapoperative radiotherapy equipment-photon radiosurgery system
-
doi:10.1186/1748-717X-2-11
-
Armoogum K-S, Parry J-M, Souliman S-K, et al. Functional intercomparison of intrapoperative radiotherapy equipment-photon radiosurgery system. Radiat Oncol 2007;2: doi:10.1186/1748-717X-2-11
-
(2007)
Radiat Oncol
, Issue.2
-
-
Armoogum, K.-S.1
Parry, J.-M.2
Souliman, S.-K.3
-
12
-
-
70749098720
-
Dosimetrie von Röntgenstrahlen im niederen und mittleren Energiebereich
-
Schweizerische Gesellschaft für Strahlenbiologie und Medizinische Physik
-
Schweizerische Gesellschaft für Strahlenbiologie und Medizinische Physik. Dosimetrie von Röntgenstrahlen im niederen und mittleren Energiebereich. Empfehlungen 2001;9.
-
(2001)
Empfehlungen
, pp. 9
-
-
-
13
-
-
70749133236
-
-
DIN 6809 Teil4. Berlin: Beuth Verlag; 1988.
-
DIN 6809 Teil4. Berlin: Beuth Verlag; 1988.
-
-
-
-
14
-
-
70749121377
-
Praxis der Weichstrahldosimetrie. DGMP-Bericht
-
Heuß K, Bunde E, Dierker J, et al. Praxis der Weichstrahldosimetrie. DGMP-Bericht 1986;5.
-
(1986)
, pp. 5
-
-
Heuß, K.1
Bunde, E.2
Dierker, J.3
-
15
-
-
70749090901
-
-
® System PRS 500 mit XRS 4Software-Version 2.1 Gebrauchsanweisung für das Kernsystem. 2007 G-30-1601-de
-
® System PRS 500 mit XRS 4Software-Version 2.1 Gebrauchsanweisung für das Kernsystem. 2007 G-30-1601-de.
-
-
-
-
16
-
-
44449108024
-
A dosimetry intercomparison phantom for intraoperative radiotherapy
-
Armoogum K., and Watson C. A dosimetry intercomparison phantom for intraoperative radiotherapy. Z Med Phys 18 (2008) 120-127
-
(2008)
Z Med Phys
, vol.18
, pp. 120-127
-
-
Armoogum, K.1
Watson, C.2
-
17
-
-
70749156052
-
-
Schiebel R. Evaluation der 2-D Bestrahlungsplanung durch Task Group No. 43 Protokoll mit GafChromik Filmdosimeter Diplomarbeit im Studiengang Medizintechnik Fachhochschule Giessen-Friedberg; 2005.
-
Schiebel R. Evaluation der 2-D Bestrahlungsplanung durch Task Group No. 43 Protokoll mit GafChromik Filmdosimeter Diplomarbeit im Studiengang Medizintechnik Fachhochschule Giessen-Friedberg; 2005.
-
-
-
|