메뉴 건너뛰기




Volumn 8, Issue 3, 2009, Pages 207-217

Domain decomposition technique applied to the evaluation of cross-ventilation performance of opening positions of a building

Author keywords

CFD; Cross ventilation; Discharge coefficient; Wind tunnel experiment

Indexed keywords

AIR; AIR CONDITIONING; DOMAIN DECOMPOSITION METHODS; FLOW FIELDS; HEAT CONVECTION; HEAT TRANSFER; SENSORY PERCEPTION; THERMAL COMFORT; VENTILATION; WIND TUNNELS;

EID: 70749143444     PISSN: 14733315     EISSN: None     Source Type: Journal    
DOI: 10.1080/14733315.2009.11683846     Document Type: Conference Paper
Times cited : (13)

References (9)
  • 1
    • 0030087363 scopus 로고    scopus 로고
    • On the k-3 stagnation point anomaly 2
    • Durbin PA: (1996). "On the k-3 stagnation point anomaly 2", Int. J. Heat and Fluid Flow, 17, (1).
    • (1996) Int. J. Heat and Fluid Flow , vol.17 , Issue.1
    • Durbin, P.A.1
  • 2
    • 33748803451 scopus 로고    scopus 로고
    • Study on the Numerical Predictive Accuracy of Wind Pressure Distribution and Air Flow Characteristics - Part 1 Optimization of Turbulence Models for Practical Use; Part2 Prediction Accuracy of Wind Pressure Distribution of Various Shaped Buildings
    • Endo T, Kurabuchi T, Ishii M, Komamura K, Maruta E and Sawachi T: (2005) "Study on the Numerical Predictive Accuracy of Wind Pressure Distribution and Air Flow Characteristics - Part 1 Optimization of Turbulence Models for Practical Use; Part2 Prediction Accuracy of Wind Pressure Distribution of Various Shaped Buildings". The International Journal of Ventilation, 4, (3), pp269-284.
    • (2005) The International Journal of Ventilation , vol.4 , Issue.3 , pp. 269-284
    • Endo, T.1    Kurabuchi, T.2    Ishii, M.3    Komamura, K.4    Maruta, E.5    Sawachi, T.6
  • 3
    • 33748764645 scopus 로고    scopus 로고
    • Development of a Simulator for Indoor Airflow Distribution in a Cross-Ventilated Building using the Local Dynamic Similarity Model
    • Endo T, Kurabuchi T, Nonaka T, Ishii M, Ohba M, Goto T and Akamine Y: (2006). "Development of a Simulator for Indoor Airflow Distribution in a Cross-Ventilated Building using the Local Dynamic Similarity Model". The International Journal of Ventilation, 5, (1). pp31-42.
    • (2006) The International Journal of Ventilation , vol.5 , Issue.1 , pp. 31-42
    • Endo, T.1    Kurabuchi, T.2    Nonaka, T.3    Ishii, M.4    Ohba, M.5    Goto, T.6    Akamine, Y.7
  • 4
    • 0019565685 scopus 로고
    • A simple omnidirectional sensor for wind-tunnel studies of pedestrian-level winds
    • Irwin HPAH: (1981) "A simple omnidirectional sensor for wind-tunnel studies of pedestrian-level winds", Journal of Wind Engineering and Industrial Aerodynamics, 7, pp219-239.
    • (1981) Journal of Wind Engineering and Industrial Aerodynamics , vol.7 , pp. 219-239
    • Irwin, H.P.A.H.1
  • 6
    • 33748787811 scopus 로고    scopus 로고
    • Kurabuchi T, Ohba M, Goto T, Akamine Y, Endo T and Kamata M: (2005). Local Dynamic Similarity Concept as Applied to Evaluation of Discharge Coefficients of Cross-Ventilated Building - Part 1 Basic Idea and Underlying Wind Tunnel Tests; Part 2 Applicability of Local Dynamic Similarity Concept; Part 3 Simplified Method for Estimating Dynamic Pressure Tangential to Openings of Cross-Ventilated Buildings. The International Journal of Ventilation, 4, (3), pp285-300.
    • Kurabuchi T, Ohba M, Goto T, Akamine Y, Endo T and Kamata M: (2005). "Local Dynamic Similarity Concept as Applied to Evaluation of Discharge Coefficients of Cross-Ventilated Building - Part 1 Basic Idea and Underlying Wind Tunnel Tests; Part 2 Applicability of Local Dynamic Similarity Concept; Part 3 Simplified Method for Estimating Dynamic Pressure Tangential to Openings of Cross-Ventilated Buildings". The International Journal of Ventilation, 4, (3), pp285-300.
  • 7
    • 33748786223 scopus 로고    scopus 로고
    • A Study on the Effects of Porosity on Discharge Coefficient in Cross-Ventilated Buildings Based on Wind Tunnel Experiments
    • Kurabuchi T, Akamine Y, Ohba M, Endo T, Goto T and Kamata M: (2006). "A Study on the Effects of Porosity on Discharge Coefficient in Cross-Ventilated Buildings Based on Wind Tunnel Experiments". The International Journal of Ventilation, 5. (1), pp67-78.
    • (2006) The International Journal of Ventilation , vol.5 , Issue.1 , pp. 67-78
    • Kurabuchi, T.1    Akamine, Y.2    Ohba, M.3    Endo, T.4    Goto, T.5    Kamata, M.6
  • 8
    • 0025846162 scopus 로고
    • Wind tunnel test on velocity pressure field of cross-ventilation with open windows
    • Murakami S, Kato S, Akabayashi S, Mizutani K and Kim YD: (1991) "Wind tunnel test on velocity pressure field of cross-ventilation with open windows", ASHRAE Transactions, 97, (1), pp525-538.
    • (1991) ASHRAE Transactions , vol.97 , Issue.1 , pp. 525-538
    • Murakami, S.1    Kato, S.2    Akabayashi, S.3    Mizutani, K.4    Kim, Y.D.5
  • 9
    • 33748791178 scopus 로고    scopus 로고
    • Experimental Study on Predicting Wind Driven Cross-Ventilation Flow Rates and Discharge Coefficients Based on the Local Dynamic Similarity Model
    • Ohba M., Goto T., Kurabuchi T., Endo T. and Akamine Y.: (2006). "Experimental Study on Predicting Wind Driven Cross-Ventilation Flow Rates and Discharge Coefficients Based on the Local Dynamic Similarity Model". The International Journal of Ventilation, 5, (1). pp105-114.
    • (2006) The International Journal of Ventilation , vol.5 , Issue.1 , pp. 105-114
    • Ohba, M.1    Goto, T.2    Kurabuchi, T.3    Endo, T.4    Akamine, Y.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.