메뉴 건너뛰기




Volumn , Issue , 2007, Pages 53-58

Optimization criteria in the design of medical UWB radars in compliance with the regulatory masks

Author keywords

[No Author keywords available]

Indexed keywords

ACQUISITION TIME; GENERAL METHOD; HEART MOTION; HEART WALL; MOTION SIGNALS; OPTIMAL SETS; OPTIMIZATION CRITERIA; PARAMETERS SETTING; POWER LIMITATIONS; PULSE ECHOES; PULSE POWER; PULSE REPETITION FREQUENCIES; SAMPLING FREQUENCIES; UWB EMISSIONS; UWB RADARS;

EID: 70450246794     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/BIOCAS.2007.4463307     Document Type: Conference Paper
Times cited : (9)

References (15)
  • 1
    • 84962664196 scopus 로고    scopus 로고
    • Everything you always wanted to know about UWB radars
    • Web broadcasted on Jan 16th (as visited on Dec 2006)
    • Staderini E.M. Everything you always wanted to know about UWB radars. Online Symposium for Electronics Engineers. Web broadcasted on Jan 16th, 2001. http://www.techonline.com/learning/course/100220 (as visited on Dec 2006).
    • (2001) Online Symposium for Electronics Engineers
    • Staderini, E.M.1
  • 2
    • 0036249853 scopus 로고    scopus 로고
    • UWB radars in medicine
    • Staderini E.M. UWB radars in medicine. IEEE AESS Magazine, (2002) 17: 1; 13-18.
    • (2002) IEEE AESS Magazine , vol.17 , Issue.1 , pp. 13-18
    • Staderini, E.M.1
  • 4
    • 0003521312 scopus 로고    scopus 로고
    • Federal communications commission, revision of Part 15 of the commission's rules regarding ultra-wide band transmission systems
    • Apr
    • Federal Communications Commission, Revision of Part 15 of the commission's rules regarding Ultra-Wide band Transmission systems, ET Docket 98-153, Apr 2002.
    • (2002) ET Docket 98-153
  • 5
    • 77956387490 scopus 로고    scopus 로고
    • E&ECE Department, IIT Kharagpur, G.S. Sanyal School of Telecommunications, IIT Kharagpur - 721302, India saswat@ece.iitkgp.ernet. insrinu-maddula@yahoo.co.in
    • Srinivasu M. Saswat C. Synthesis of UWB Pulse Following FCC mask. E&ECE Department, IIT Kharagpur, G.S. Sanyal School of Telecommunications, IIT Kharagpur - 721302, India saswat@ece.iitkgp.ernet.in srinu-maddula@yahoo.co. in.
    • Synthesis of UWB Pulse Following FCC Mask
    • Srinivasu, M.1    Saswat, C.2
  • 9
    • 0003610612 scopus 로고    scopus 로고
    • Evaluating compliance with FCC guidelines for human exposure to radiofrequency electromagnetic fields
    • Washington, DC, Tech. Rep. OET Bull. Aug.
    • Evaluating compliance with FCC guidelines for human exposure to radiofrequency electromagnetic fields. FCC, Washington, DC, Tech. Rep. OET Bull. 65, Aug. 1997.
    • (1997) FCC , vol.65
  • 10
    • 0019523842 scopus 로고
    • Direct blood pressure measurement-dynamic response requirements
    • Gardner R.M. Direct blood pressure measurement-dynamic response requirements. Anesthesiology (1981) 54: 227-36.
    • (1981) Anesthesiology , vol.54 , pp. 227-236
    • Gardner, R.M.1
  • 11
    • 0023786403 scopus 로고
    • Frequency response evaluation of radial artery catheter-manometer systems: Sinusoidal frequency analysis versus flush method
    • Schwid H.A. Frequency response evaluation of radial artery catheter-manometer systems: Sinusoidal frequency analysis versus flush method. Journal of Clinical Monitoring and Computing (1988) 4: 3; 181-85.
    • (1988) Journal of Clinical Monitoring and Computing , vol.4 , Issue.3 , pp. 181-185
    • Schwid, H.A.1
  • 14
    • 0000515502 scopus 로고
    • Nuclear spin relaxation in alkali metals
    • Holcomb D.F. and Norberg R.E. Nuclear spin relaxation in alkali metals. Phys. Rev. (1955) 98: 4; 1074-91.
    • (1955) Phys. Rev. , vol.98 , Issue.4 , pp. 1074-1091
    • Holcomb, D.F.1    Norberg, R.E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.