메뉴 건너뛰기




Volumn 94, Issue 1, 2010, Pages 53-59

A flow-based procedure with solenoid micro-pumps for the spectrophotometric determination of uric acid in urine

Author keywords

Clinical analysis; Flow analysis; Multicommutation; Uric acid; Urine

Indexed keywords


EID: 70450223911     PISSN: 0026265X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.microc.2009.08.010     Document Type: Article
Times cited : (83)

References (38)
  • 4
    • 0023688714 scopus 로고
    • The Lesch-Nyhan syndrome: clinical, molecular and genetic aspects
    • Stout J.T., and Caskey C.T. The Lesch-Nyhan syndrome: clinical, molecular and genetic aspects. Trends Gen. 4 (1988) 175-178
    • (1988) Trends Gen. , vol.4 , pp. 175-178
    • Stout, J.T.1    Caskey, C.T.2
  • 5
    • 13444309288 scopus 로고    scopus 로고
    • Uric acid: an abettor or protector in calcium oxalate urolithiasis? Biochemical study in stone formers
    • Srinivasan S., Kalaiselvi P., Sakthivel R., Pragasam V., Muthu V., and Varalakshmi P. Uric acid: an abettor or protector in calcium oxalate urolithiasis? Biochemical study in stone formers. Clin. Chim. Acta 353 (2005) 45-51
    • (2005) Clin. Chim. Acta , vol.353 , pp. 45-51
    • Srinivasan, S.1    Kalaiselvi, P.2    Sakthivel, R.3    Pragasam, V.4    Muthu, V.5    Varalakshmi, P.6
  • 6
    • 0004959158 scopus 로고
    • Direct determination of uric acid using uricase
    • Feichtmeier T.V., and Wrenn H.T. Direct determination of uric acid using uricase. Am. J. Clin. Pathol. 25 (1955) 833-839
    • (1955) Am. J. Clin. Pathol. , vol.25 , pp. 833-839
    • Feichtmeier, T.V.1    Wrenn, H.T.2
  • 7
    • 0018865050 scopus 로고
    • Use of 3,5-dichloro-2-hydroxybenzenesulphonic acid/4-aminophenazone chromogenic system in direct enzymic assay of uric acid in serum and urine
    • Fossati P., Prencipe L., and Berti G. Use of 3,5-dichloro-2-hydroxybenzenesulphonic acid/4-aminophenazone chromogenic system in direct enzymic assay of uric acid in serum and urine. Clin. Chem. 26 (1980) 227-231
    • (1980) Clin. Chem. , vol.26 , pp. 227-231
    • Fossati, P.1    Prencipe, L.2    Berti, G.3
  • 8
    • 0016954559 scopus 로고
    • Potentiometric enzyme electrode for uric acid
    • Kawashima T., and Rechnitz G.A. Potentiometric enzyme electrode for uric acid. Anal. Chim. Acta 83 (1976) 9-17
    • (1976) Anal. Chim. Acta , vol.83 , pp. 9-17
    • Kawashima, T.1    Rechnitz, G.A.2
  • 9
    • 0019249616 scopus 로고
    • Continuous-flow analysis for uric acid in biological fluids, with immobilized uricase in a closed-loop system
    • Iob A., and Mottola H.A. Continuous-flow analysis for uric acid in biological fluids, with immobilized uricase in a closed-loop system. Anal. Chem. 52 (1980) 2332-2336
    • (1980) Anal. Chem. , vol.52 , pp. 2332-2336
    • Iob, A.1    Mottola, H.A.2
  • 10
    • 0028436345 scopus 로고
    • Novel, reagentless, amperometric biosensor for uric acid based on a chemically modified screen-printed carbon electrode coated with cellulose acetate and uricase
    • Gilmartin M.A.T., and Hart J.P. Novel, reagentless, amperometric biosensor for uric acid based on a chemically modified screen-printed carbon electrode coated with cellulose acetate and uricase. Analyst 119 (1994) 833-840
    • (1994) Analyst , vol.119 , pp. 833-840
    • Gilmartin, M.A.T.1    Hart, J.P.2
  • 11
    • 0019479072 scopus 로고
    • Quantitation of urinary uric acid by reversed-phase liquid chromatography
    • Hausen A., Fuchs D., Köing K., and Wachter H. Quantitation of urinary uric acid by reversed-phase liquid chromatography. Clin. Chem. 27 (1981) 1455-1456
    • (1981) Clin. Chem. , vol.27 , pp. 1455-1456
    • Hausen, A.1    Fuchs, D.2    Köing, K.3    Wachter, H.4
  • 12
    • 70450221477 scopus 로고    scopus 로고
    • Automatic determination of uric acid in urine in a FIA system with tubular amperometric detector
    • Garcia M.B.Q., Lima J.F.L.C., Silva M.L., and Sousa J.P. Automatic determination of uric acid in urine in a FIA system with tubular amperometric detector. Portugaliae Electrochim. Acta 22 (2004) 249-262
    • (2004) Portugaliae Electrochim. Acta , vol.22 , pp. 249-262
    • Garcia, M.B.Q.1    Lima, J.F.L.C.2    Silva, M.L.3    Sousa, J.P.4
  • 13
    • 29144501622 scopus 로고    scopus 로고
    • Multicommutated flow system with amperometric detection. Determination of uric acid in urine
    • Silva M.L.S., Garcia M.B.Q., Lima J.L.F.C., Santos J.L.M., and Barrado E. Multicommutated flow system with amperometric detection. Determination of uric acid in urine. Electroanalysis 23 (2005) 2156-2162
    • (2005) Electroanalysis , vol.23 , pp. 2156-2162
    • Silva, M.L.S.1    Garcia, M.B.Q.2    Lima, J.L.F.C.3    Santos, J.L.M.4    Barrado, E.5
  • 14
    • 0015310255 scopus 로고
    • A one-tube serum uric acid method using phosphotungstic acid as protein precipitant and color reagent
    • Pileggi V.J., Giorgio J.D., and Wybenga D.R. A one-tube serum uric acid method using phosphotungstic acid as protein precipitant and color reagent. Clin. Chim. Acta 37 (1972) 141-149
    • (1972) Clin. Chim. Acta , vol.37 , pp. 141-149
    • Pileggi, V.J.1    Giorgio, J.D.2    Wybenga, D.R.3
  • 15
    • 0040020356 scopus 로고    scopus 로고
    • Kinetic determination of uric acid in urine based on single-line flow system with multi-site detection
    • Araújo A.N., Catita J.A.M., and Lima J.L.F.C. Kinetic determination of uric acid in urine based on single-line flow system with multi-site detection. Anal. Sci. 14 (1998) 809-813
    • (1998) Anal. Sci. , vol.14 , pp. 809-813
    • Araújo, A.N.1    Catita, J.A.M.2    Lima, J.L.F.C.3
  • 20
    • 42749090620 scopus 로고    scopus 로고
    • An improved procedure for flow-based turbidimetric sulphate determination based on a liquid core waveguide and pulsed flows
    • Melchert W.R., and Rocha F.R.P. An improved procedure for flow-based turbidimetric sulphate determination based on a liquid core waveguide and pulsed flows. Anal. Chim. Acta 616 (2008) 56-62
    • (2008) Anal. Chim. Acta , vol.616 , pp. 56-62
    • Melchert, W.R.1    Rocha, F.R.P.2
  • 21
    • 33847134343 scopus 로고    scopus 로고
    • Development and critical comparison of greener flow procedures for nitrite determination in natural waters
    • Melchert W.R., Infante C.M.C., and Rocha F.R.P. Development and critical comparison of greener flow procedures for nitrite determination in natural waters. Microchem. J. 85 (2007) 209-213
    • (2007) Microchem. J. , vol.85 , pp. 209-213
    • Melchert, W.R.1    Infante, C.M.C.2    Rocha, F.R.P.3
  • 22
    • 33745527569 scopus 로고    scopus 로고
    • Multi-pumping flow system for the determination of dissolved orthophosphate and dissolved organic phosphorus in wastewater samples
    • Pons C., Tóth I.V., Rangel A.O.S.S., Forteza R., and Cerda V. Multi-pumping flow system for the determination of dissolved orthophosphate and dissolved organic phosphorus in wastewater samples. Anal. Chim. Acta 572 (2006) 148-154
    • (2006) Anal. Chim. Acta , vol.572 , pp. 148-154
    • Pons, C.1    Tóth, I.V.2    Rangel, A.O.S.S.3    Forteza, R.4    Cerda, V.5
  • 23
    • 0042625014 scopus 로고    scopus 로고
    • Multi-pumping flow system for the spectrophotometric determination of dipyrone in pharmaceutical preparations
    • Lima J.L.F.C., Sa S.M.O., Santos J.L.M., and Zagatto E.A.G. Multi-pumping flow system for the spectrophotometric determination of dipyrone in pharmaceutical preparations. J. Pharm. Biom. Anal. 32 (2003) 1011-1017
    • (2003) J. Pharm. Biom. Anal. , vol.32 , pp. 1011-1017
    • Lima, J.L.F.C.1    Sa, S.M.O.2    Santos, J.L.M.3    Zagatto, E.A.G.4
  • 24
    • 33748529956 scopus 로고    scopus 로고
    • Multicommuted flow system employing pinch solenoid valves and micro-pumps. Spectrophotometric determination of paracetamol in pharmaceutical formulations
    • Lavorante A.F., Pires C.K., and Reis B.F. Multicommuted flow system employing pinch solenoid valves and micro-pumps. Spectrophotometric determination of paracetamol in pharmaceutical formulations. J. Pharm. Biomed. Anal. 42 (2006) 423-429
    • (2006) J. Pharm. Biomed. Anal. , vol.42 , pp. 423-429
    • Lavorante, A.F.1    Pires, C.K.2    Reis, B.F.3
  • 25
    • 23044505473 scopus 로고    scopus 로고
    • A clean method for flow injection spectrophotometric determination of cyclamate in table sweeteners
    • Rocha F.R.P., Ródenas-Torralba E., Morales-Rubio A., and de la Guardia M. A clean method for flow injection spectrophotometric determination of cyclamate in table sweeteners. Anal. Chim. Acta 547 (2005) 204-208
    • (2005) Anal. Chim. Acta , vol.547 , pp. 204-208
    • Rocha, F.R.P.1    Ródenas-Torralba, E.2    Morales-Rubio, A.3    de la Guardia, M.4
  • 26
    • 33646783970 scopus 로고    scopus 로고
    • A multi-pumping flow system for chemiluminometric determination of ascorbic acid in powdered materials for preparation of fruit juices
    • Pires C.K., Lavorante A.F., Marconi L.M.T., Meneses S.R.P., and Zagatto E.A.G. A multi-pumping flow system for chemiluminometric determination of ascorbic acid in powdered materials for preparation of fruit juices. Microchem. J. 83 (2006) 70-74
    • (2006) Microchem. J. , vol.83 , pp. 70-74
    • Pires, C.K.1    Lavorante, A.F.2    Marconi, L.M.T.3    Meneses, S.R.P.4    Zagatto, E.A.G.5
  • 27
    • 33751086744 scopus 로고    scopus 로고
    • A multi-purpose flow system based on multi-commutation
    • Rocha F.R.P., Infante C.M.C., and Melchert W.R. A multi-purpose flow system based on multi-commutation. Spect. Lett. 39 (2006) 651-668
    • (2006) Spect. Lett. , vol.39 , pp. 651-668
    • Rocha, F.R.P.1    Infante, C.M.C.2    Melchert, W.R.3
  • 28
    • 0028945240 scopus 로고
    • A quantitative test for copper using bicinchoninic acid
    • Brenner A.J., and Harris E.D. A quantitative test for copper using bicinchoninic acid. Anal. Biochem. 226 (1995) 80-84
    • (1995) Anal. Biochem. , vol.226 , pp. 80-84
    • Brenner, A.J.1    Harris, E.D.2
  • 30
    • 37049027078 scopus 로고    scopus 로고
    • A multicommuted flow system for spectrophotometric determination of tannin exploiting the Cu(I)/BCA complex formation
    • Moya H.D., Dantoni P., Rocha F.R.P., and Coichev N. A multicommuted flow system for spectrophotometric determination of tannin exploiting the Cu(I)/BCA complex formation. Microchem. J. 88 (2008) 21-25
    • (2008) Microchem. J. , vol.88 , pp. 21-25
    • Moya, H.D.1    Dantoni, P.2    Rocha, F.R.P.3    Coichev, N.4
  • 31
    • 0028146269 scopus 로고
    • Multicommutation in flow analysis. Part 1. Binary sampling: concepts, instrumentation and spectrophotometric determination of iron in plant digests
    • Reis B.F., Giné M.F., Zagatto E.A.G., Lima J.L.F.C., and Lapa R.A. Multicommutation in flow analysis. Part 1. Binary sampling: concepts, instrumentation and spectrophotometric determination of iron in plant digests. Anal. Chim. Acta 293 (1994) 129-138
    • (1994) Anal. Chim. Acta , vol.293 , pp. 129-138
    • Reis, B.F.1    Giné, M.F.2    Zagatto, E.A.G.3    Lima, J.L.F.C.4    Lapa, R.A.5
  • 34
    • 34248583784 scopus 로고    scopus 로고
    • Spectrophotometric determination of uric acid based on fading of o-hydroxyhydroquinonephthalein-palladium(II)-hexadecyltrimethyl-ammonium complex
    • Yamaguchi T., Hasegawa K., Kamino S., Miyachi K., Tominaga H., and Fujita Y. Spectrophotometric determination of uric acid based on fading of o-hydroxyhydroquinonephthalein-palladium(II)-hexadecyltrimethyl-ammonium complex. Anal. Sci. 23 (2007) 223-226
    • (2007) Anal. Sci. , vol.23 , pp. 223-226
    • Yamaguchi, T.1    Hasegawa, K.2    Kamino, S.3    Miyachi, K.4    Tominaga, H.5    Fujita, Y.6
  • 36
    • 44949097304 scopus 로고    scopus 로고
    • Are preservatives necessary in 24-hour urine measurements?
    • Yilmaz G., Yilmaz F.M., Hakligör A., and Yücel D. Are preservatives necessary in 24-hour urine measurements?. Clin. Biochem. 41 (2008) 899-901
    • (2008) Clin. Biochem. , vol.41 , pp. 899-901
    • Yilmaz, G.1    Yilmaz, F.M.2    Hakligör, A.3    Yücel, D.4
  • 37
    • 0016120662 scopus 로고
    • Determination of uric acid at the microgram level by a kinetic procedure based on a "pseudo-induction" period
    • Dutt V.V.S.E., and Mottola H.A. Determination of uric acid at the microgram level by a kinetic procedure based on a "pseudo-induction" period. Anal. Chem. 46 (1974) 1777-1781
    • (1974) Anal. Chem. , vol.46 , pp. 1777-1781
    • Dutt, V.V.S.E.1    Mottola, H.A.2
  • 38
    • 0001672609 scopus 로고
    • Flow injection spectrophotometric determination of cyclamate in low calorie soft drinks and sweeteners
    • Gouveia S.T., Fatibello-Filho O., and Nóbrega J.A. Flow injection spectrophotometric determination of cyclamate in low calorie soft drinks and sweeteners. Analyst 120 (1995) 2009-2012
    • (1995) Analyst , vol.120 , pp. 2009-2012
    • Gouveia, S.T.1    Fatibello-Filho, O.2    Nóbrega, J.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.