-
1
-
-
0014117068
-
An experimental multiple barbed suture for the long flexor tendons of the palm and fingers. Preliminary report
-
McKenzie AR. An experimental multiple barbed suture for the long flexor tendons of the palm and fingers. Preliminary report. J Bone Joint Surg Br 1967; 49(3):440-447.
-
(1967)
J Bone Joint Surg Br
, vol.49
, Issue.3
, pp. 440-447
-
-
McKenzie, A.R.1
-
2
-
-
0014319679
-
A method of flexor tendon suture
-
Shaw PC. A method of flexor tendon suture. J Bone Joint Surg Br 1968; 50(3):578-587.
-
(1968)
J Bone Joint Surg Br
, vol.50
, Issue.3
, pp. 578-587
-
-
Shaw, P.C.1
-
3
-
-
48449105695
-
Long-term efficacy of anchored barbed sutures in the face and neck
-
Kaminer MS, Bogart M, Choi C, Wee SA. Long-term efficacy of anchored barbed sutures in the face and neck. Dermatol Surg 2008; 34(8):1041-1047.
-
(2008)
Dermatol Surg
, vol.34
, Issue.8
, pp. 1041-1047
-
-
Kaminer, M.S.1
Bogart, M.2
Choi, C.3
Wee, S.A.4
-
4
-
-
33646845765
-
Evaluation of a novel technique for wound closure using a barbed suture
-
Murtha AP, Kaplan AL, Paglia MJ, Mills BB, Feldstein ML, Ruff GL. Evaluation of a novel technique for wound closure using a barbed suture. Plast Reconstr Surg 2006; 117(6):1769-1780.
-
(2006)
Plast Reconstr Surg
, vol.117
, Issue.6
, pp. 1769-1780
-
-
Murtha, A.P.1
Kaplan, A.L.2
Paglia, M.J.3
Mills, B.B.4
Feldstein, M.L.5
Ruff, G.L.6
-
5
-
-
40549144584
-
Barbed sutures: A review of the literature
-
Villa MT, White LE, Alam M, Yoo SS, Walton RL. Barbed sutures: a review of the literature. Plast Reconstr Surg 2008; 121(3):102e-108e.
-
(2008)
Plast Reconstr Surg
, vol.121
, Issue.3
-
-
Villa, M.T.1
White, L.E.2
Alam, M.3
Yoo, S.S.4
Walton, R.L.5
-
6
-
-
0037515321
-
The effect of increased peripheral suture purchase on the strength of flexor tendon repairs
-
DOI 10.1053/jhsu.2003.50074
-
Merrell GA, Wolfe SW, Kacena WJ, Gao Y, Cholewicki J, Kacena MA. The effect of increased peripheral suture purchase on the strength of flexor tendon repairs. J Hand Surg Am 2003; 28(3):464-468. (Pubitemid 36617804)
-
(2003)
Journal of Hand Surgery
, vol.28
, Issue.3
, pp. 464-468
-
-
Merrell, G.A.1
Wolfe, S.W.2
Kacena, W.J.3
Gao, Y.4
Cholewicki, J.5
Kacena, M.A.6
-
7
-
-
0026508971
-
The mechanical strength of various suture techniques
-
Trail IA, Powell ES, Noble J. The mechanical strength of various suture techniques. J Hand Surg Br 1992; 17(1):89-91.
-
(1992)
J Hand Surg Br
, vol.17
, Issue.1
, pp. 89-91
-
-
Trail, I.A.1
Powell, E.S.2
Noble, J.3
-
8
-
-
0343342079
-
Gig pull-out suture for tendons
-
Bunnell S. Gig pull-out suture for tendons. J Bone Joint Surg Am 1954; 36(4):850-851.
-
(1954)
J Bone Joint Surg Am
, vol.36
, Issue.4
, pp. 850-851
-
-
Bunnell, S.1
-
9
-
-
0004183398
-
-
3rd Edition. London, England: Pitman Medical Publishing Co Ltd
-
Bunnell S. Surgery of the Hand 3rd Edition. London, England: Pitman Medical Publishing Co Ltd; 1956:474-522.
-
(1956)
Surgery of the Hand
, pp. 474-522
-
-
Bunnell, S.1
-
10
-
-
50349124596
-
Metal anastomosis tubes in tendon suture
-
McKee GK. Metal anastomosis tubes in tendon suture. Lancet 1945; (245):659-660.
-
(1945)
Lancet
, vol.245
, pp. 659-660
-
-
McKee, G.K.1
-
11
-
-
0034948985
-
Biomechanical assessment of a new type of flexor tendon repair
-
DOI 10.1054/jhsb.2000.0542
-
Smith AM, Evans DM. Biomechanical assessment of a new type of flexor tendon repair. J Hand Surg Br 2001; 26(3):217-219. (Pubitemid 32586298)
-
(2001)
Journal of Hand Surgery
, vol.26 B
, Issue.3
, pp. 217-219
-
-
Smith, A.M.1
Evans, D.M.2
-
12
-
-
0034193847
-
A biomechanical comparison of multistrand flexor tendon repairs using an in situ testing model
-
DOI 10.1053/jhsu.2000.6927
-
Barrie KA, Wolfe SW, Shean C, Shenbagamurthi D, Slade JF III, Panjabi MM. A biomechanical comparison of multistrand flexor tendon repairs using an in situ testing model. J Hand Surg Am 2000; 25(3):499-506. (Pubitemid 30354310)
-
(2000)
Journal of Hand Surgery
, vol.25
, Issue.3
, pp. 499-506
-
-
Barrie, K.A.1
Wolfe, S.W.2
Shean, C.3
Shenbagamurthi, D.4
Slade III, J.F.5
Panjabi, M.M.6
-
13
-
-
70450137683
-
Flexor tendon repair with barbed suture
-
Abstract presented at
-
Abathi F, Saint-Cyr M, Brown S, et al. Flexor tendon repair with barbed suture. Abstract presented at: Plastic Surgery 2007; October 26-31, 2007; Baltimore, Maryland.
-
Plastic Surgery 2007; October 26-31, 2007; Baltimore, Maryland
-
-
Abathi, F.1
Saint-Cyr, M.2
Brown, S.3
-
14
-
-
0032469801
-
A randomized biomechanical study of zone II human flexor tendon repairs analyzed in an in vitro model
-
Stein T, Ali A, Hamman J, Mass DP. A randomized biomechanical study of zone II human flexor tendon repairs analyzed in an in vitro model. J Hand Surg Am 1998; 23(6):1046-1051. (Pubitemid 29102312)
-
(1998)
Journal of Hand Surgery
, vol.23
, Issue.6
, pp. 1046-1051
-
-
Stein, T.1
Ali, A.2
Hamman, J.3
Mass, D.P.4
-
15
-
-
0033019120
-
Biomechanical analysis of the cruciate four-strand flexor tendon repair
-
DOI 10.1053/jhsu.1999.0295
-
McLarney E, Hoffman H, Wolfe SW. Biomechanical analysis of the cruciate four-strand flexor tendon repair. J Hand Surg Am 1999; 24(2):295-301. (Pubitemid 29149179)
-
(1999)
Journal of Hand Surgery
, vol.24
, Issue.2
, pp. 295-301
-
-
McLarney, E.1
Hoffman, H.2
Wolfe, S.W.3
|