메뉴 건너뛰기




Volumn 8, Issue 7, 2009, Pages 289-298

Defect detection and characteristics description of auto hub radiographic image based on SUSAN operation

Author keywords

Auto hub; Edge detection; Feature description; Geometrical features; Mask; Shape Features; SUSAN operation

Indexed keywords

ANTI-INTERFERENCE; CENTER OF GRAVITY; CIRCLE DEGREE; DEFECT DETECTION; DEFECT IMAGES; DETECTION ACCURACY; DETECTION EFFICIENCY; DETECTION OF DEFECTS; FEATURE DESCRIPTION; GEOMETRICAL FEATURES; HIGH EFFICIENCY; NOISE SOURCE; RADIOGRAPHIC IMAGES; REAL-TIME DETECTION; SHAPE FEATURES; SUSAN OPERATOR; TARGET OBJECT; X-RAY DETECTIONS;

EID: 70450184387     PISSN: 11092769     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (1)

References (20)
  • 1
    • 33947229857 scopus 로고    scopus 로고
    • Automatic inspection of alumi ingots by digital radioscopy
    • New Delhi
    • Valerie Kaftandjian, Yue Min Zhu,Gilles Peix et al.Automatic Inspection of Alumi Ingots by Digital Radioscopy.Proceedings of the 14th WCNDT,New Delhi,1996,(3):1338.
    • (1996) Proceedings of the 14th WCNDT , vol.3 , pp. 1338
    • Kaftandjian, V.1    Zhu, Y.M.2    Peix, G.3
  • 4
    • 0020185791 scopus 로고
    • Scatter imaging of aluminum castings using an X-Ray fan beam and a pinpole camera
    • H.Strecker. Scatter Imaging of Aluminum Castings Using an X-Ray Fan Beam and a Pinpole Camera. Material Evaluation.1982,40:1050-1056.
    • (1982) Material Evaluation , vol.40 , pp. 1050-1056
    • Strecker, H.1
  • 7
    • 69249112439 scopus 로고    scopus 로고
    • Improvement in automated aluminum casting inspectionby finding correspondence of potential flaws in multiple radioscopic images
    • Rome
    • Domongo Mery,Dieter Filbert.Improvement in automated Aluminum Casting Inspectionby Finding Correspondence of Potential Flaws in Multiple Radioscopic Images. Proceedings of the 15th WCNDT,Rome,2000:631-645.
    • (2000) Proceedings of the 15th WCNDT , pp. 631-645
    • Mery, D.1    Filbert, D.2
  • 10
  • 11
    • 70450217185 scopus 로고    scopus 로고
    • Improvement and application of smallest univalue segment as-similating nucleus low-level image processing algorithm [J]
    • Hong-wei Lu, Qi-feng YU. Improvement and Application of Smallest Univalue segment as-similating nucleus low-level image processing algorithm [J]. Applied Optics,2000,21(1) :32-37
    • (2000) Applied Optics , vol.21 , Issue.1 , pp. 32-37
    • Lu, H.-W.1    Yu, Q.-F.2
  • 12
    • 70450216436 scopus 로고    scopus 로고
    • Real-time detection method of defects in X-ray weld images [J]
    • Yi Sun, Hong-Yu Sun, Peng Bai, etc. real-time detection method of defects in X-ray weld images[J]. Welding Journal, 2003,25 (2) :115-120
    • (2003) Welding Journal , vol.25 , Issue.2 , pp. 115-120
    • Sun, Y.1    Sun, H.-Y.2    Bai, P.3
  • 13
    • 70450220894 scopus 로고
    • A fast operator for dtection and precision location of distinct points corners and centre of circular features [A]
    • Bern:[sn.]
    • F STNER W, G LCH E. A Fast Operator for Dtection and Precision Location of Distinct Points Corners and Centre of Circular Features[A]. In ISPRS intercommunication Workshop[C]. Bern:[sn.],1987
    • (1987) ISPRS Intercommunication Workshop [C]
    • Stner, W.F.1    Lch, E.G.2
  • 14
    • 0025465145 scopus 로고
    • Scale-space and edge detection using anisotropic diffusion [J]
    • Perona P, Malik J. Scale-Space and Edge Detection Using Anisotropic Diffusion[J].IEEE Transactions on. 1990,12(7): 629-639.
    • (1990) IEEE Transactions on , vol.12 , Issue.7 , pp. 629-639
    • Perona, P.1    Malik, J.2
  • 17
    • 70450209841 scopus 로고    scopus 로고
    • High resolution digital flat-panel X-Ray detector- performance
    • th WCNDT
    • J.M. Casagrande, A. Koch, B. Munier. High Resolution Digital Flat-Panel X-Ray Detector- Performance and NDT Applications. 2000: Roma 2000 15th WCNDT
    • (2000) NDT Applications , vol.2000
    • Casagrande, J.M.1    Koch, A.2    Munier, B.3
  • 20
    • 0000288651 scopus 로고    scopus 로고
    • CCD-based high resolution digital radiography system for nondestructive evaluation
    • NAGARKAR, V.V. CCD-based high resolution digital radiography system for nondestructive evaluation. IEEE Trans.Nucl.Sci[J], 1998, 44 (3) :885-889
    • (1998) IEEE Trans.Nucl.Sci [J] , vol.44 , Issue.3 , pp. 885-889
    • Nagarkar, V.V.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.