메뉴 건너뛰기




Volumn , Issue , 2009, Pages 437-441

Calibration of Rogowski coils at frequencies up to 10 kHz using digital sampling

Author keywords

Calibration; Current transformer; Digital sampling; Rogowski coil

Indexed keywords

CALIBRATION SYSTEM; CURRENT TRANSFORMER; DIGITAL SAMPLING; HIGH-ACCURACY; ORDER OF MAGNITUDE; POWER FREQUENCY; REFERENCE CURRENTS; ROGOWSKI COIL;

EID: 70449866789     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IMTC.2009.5168488     Document Type: Conference Paper
Times cited : (3)

References (20)
  • 1
    • 36149056380 scopus 로고
    • On a magnetic potentiometer
    • Apr
    • A. P. Chattock "On a magnetic potentiometer," Proc. Phys. Soc. London, vol. 9, no. 1, pp. 23-26, Apr. 1887.
    • (1887) Proc. Phys. Soc. London , vol.9 , Issue.1 , pp. 23-26
    • Chattock, A.P.1
  • 4
    • 55349140439 scopus 로고    scopus 로고
    • A. Werner, M. Endler, J. Geiger, and R. Koenig, W7-X magnetic diagnostics: Rogowski coil performance for very long pulses, Review of Scientific Instruments, 79, Issue 10, pp. 10F122/1-4, 2008.
    • A. Werner, M. Endler, J. Geiger, and R. Koenig, "W7-X magnetic diagnostics: Rogowski coil performance for very long pulses," Review of Scientific Instruments, Volume 79, Issue 10, pp. 10F122/1-4, 2008.
  • 5
    • 0030129508 scopus 로고    scopus 로고
    • Machinable Rogowski coil, design, and calibration
    • June
    • J. D. Ramboz, "Machinable Rogowski coil, design, and calibration," IEEE Trans. Instrum. Meas., Vol. 45, No. 2, pp. 939-943, June 2006.
    • (2006) IEEE Trans. Instrum. Meas , vol.45 , Issue.2 , pp. 939-943
    • Ramboz, J.D.1
  • 6
    • 0036638493 scopus 로고    scopus 로고
    • PCB Rogowski coils benefit relay protection
    • Jul
    • Lj. Kojovic, "PCB Rogowski coils benefit relay protection," IEEE Comput. Appl. Power, vol. 15, no. 3, pp. 50-53, Jul. 2002.
    • (2002) IEEE Comput. Appl. Power , vol.15 , Issue.3 , pp. 50-53
    • Kojovic, L.1
  • 7
    • 0034472651 scopus 로고    scopus 로고
    • PCB Rogowski coils for high di/dt current measurement
    • Galway, Ireland, pp, June
    • N. Karrer and P. Hofer-Noser, "PCB Rogowski coils for high di/dt current measurement," Proc. IEEE PESC, Galway, Ireland, pp. 1296-1301, June 2000.
    • (2000) Proc. IEEE PESC , pp. 1296-1301
    • Karrer, N.1    Hofer-Noser, P.2
  • 9
    • 42549151423 scopus 로고    scopus 로고
    • Comparative performance characteristics of current transformers and Rogowski coils used for protective relaying purposes
    • Lj. A. Kojovic, "Comparative performance characteristics of current transformers and Rogowski coils used for protective relaying purposes," IEEE PES General Meeting, 2007.
    • (2007) IEEE PES General Meeting
    • Kojovic, L.A.1
  • 10
    • 63449093983 scopus 로고    scopus 로고
    • Calibration of Rogowski coils at power frequencies using digital sampling
    • Apr, in press
    • B. Djokic, "Calibration of Rogowski coils at power frequencies using digital sampling," IEEE Trans. Instrum. Meas., Apr. 2009, in press.
    • (2009) IEEE Trans. Instrum. Meas
    • Djokic, B.1
  • 11
    • 0035414896 scopus 로고    scopus 로고
    • Phase measurement of distorted periodic signals based on nonsynchronous digital filtering
    • Aug
    • B. Djokic, E. So: "Phase measurement of distorted periodic signals based on nonsynchronous digital filtering," IEEE Trans. Instrum. Meas., Vol. 50, No. 4, 864-867, Aug. 2001.
    • (2001) IEEE Trans. Instrum. Meas , vol.50 , Issue.4 , pp. 864-867
    • Djokic, B.1    So, E.2
  • 16
    • 84932430489 scopus 로고
    • The development and performance of current comparators for audio frequencies
    • Dec
    • N. L. Kusters, W. J. M. Moore, "The development and performance of current comparators for audio frequencies," IEEE Trans. Instrum. Meas., Vol. 14, No. 4, pp. 178-190, Dec. 1965.
    • (1965) IEEE Trans. Instrum. Meas , vol.14 , Issue.4 , pp. 178-190
    • Kusters, N.L.1    Moore, W.J.M.2
  • 17
    • 70450023283 scopus 로고
    • An international comparison of currentratio standards at audio frequencies
    • Dec
    • B. L. Dunfee, W. J. M. Moore, "An international comparison of currentratio standards at audio frequencies," IEEE Trans. Instrum. Meas., Vol. 14, No. 4, pp. 172-177, Dec. 1965.
    • (1965) IEEE Trans. Instrum. Meas , vol.14 , Issue.4 , pp. 172-177
    • Dunfee, B.L.1    Moore, W.J.M.2
  • 18
    • 36149075703 scopus 로고
    • An international comparison of audiofrequency current transformer calibrations
    • W. J. M. Moore, H. Schlinke "An international comparison of audiofrequency current transformer calibrations," Metrologia, Vol. 8, pp. 37-41, 1972.
    • (1972) Metrologia , vol.8 , pp. 37-41
    • Moore, W.J.M.1    Schlinke, H.2
  • 20
    • 0025385197 scopus 로고
    • Phase measurement, traceability, and verification theory and practice
    • Feb
    • K. K. Clarke, D. T. Hess, "Phase measurement, traceability, and verification theory and practice," IEEE Trans. Instrum. Meas., Vol. 39, No. 1, pp. 52-55, Feb. 1990.
    • (1990) IEEE Trans. Instrum. Meas , vol.39 , Issue.1 , pp. 52-55
    • Clarke, K.K.1    Hess, D.T.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.