메뉴 건너뛰기




Volumn 25, Issue 8, 2009, Pages 699-708

Central ablation depth and postoperative refraction in excimer laser myopic correction measured with ultrasound, scheimpflug, and optical coherence pachymetry

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; ASTIGMATISM; CAMERA; CORNEA THICKNESS; EXCIMER LASER; HUMAN; KERATOMILEUSIS; LASER EPITHELIAL KERATOMILEUSIS; MAJOR CLINICAL STUDY; MEASUREMENT; MYOPIA; OPTICAL COHERENCE PACHYMETRY; PRIORITY JOURNAL; REFRACTIVE SURGERY; ULTRASOUND; COMPARATIVE STUDY; CORNEA; ECHOGRAPHY; EYE REFRACTION; METHODOLOGY; OPTICAL COHERENCE TOMOGRAPHY; PATHOLOGY; PATHOPHYSIOLOGY; PHYSIOLOGY; POSTOPERATIVE PERIOD; RETROSPECTIVE STUDY; VISUAL ACUITY;

EID: 70449732765     PISSN: 1081597X     EISSN: None     Source Type: Journal    
DOI: 10.3928/1081597X-20090707-04     Document Type: Article
Times cited : (22)

References (20)
  • 1
    • 0023858078 scopus 로고
    • Photorefractive keratectomy: A technique for laser refractive surgery
    • Munnerlyn CR, Koons SJ, Marshall J. Photorefractive keratectomy: a technique for laser refractive surgery. J Cataract Refract Surg. 1988;14:46-52.
    • (1988) J Cataract Refract Surg , vol.14 , pp. 46-52
    • Munnerlyn, C.R.1    Koons, S.J.2    Marshall, J.3
  • 2
    • 0033497421 scopus 로고    scopus 로고
    • Posterior corneal surface topographic changes after laser in situ keratomileusis are related to residual corneal bed thickness
    • Wang Z, Chen J, Yang B. Posterior corneal surface topographic changes after laser in situ keratomileusis are related to residual corneal bed thickness. Ophthalmology. 1999;106:406-409.
    • (1999) Ophthalmology , vol.106 , pp. 406-409
    • Wang, Z.1    Chen, J.2    Yang, B.3
  • 3
    • 0027970926 scopus 로고
    • Theoretical and clinical effect of preoperative corneal curvature on excimer laser photorefractive keratectomy for myopia
    • Blaker JW, Hersh PS. Theoretical and clinical effect of preoperative corneal curvature on excimer laser photorefractive keratectomy for myopia. J Refract Corneal Surg. 1994;10:571-574.
    • (1994) J Refract Corneal Surg , vol.10 , pp. 571-574
    • Blaker, J.W.1    Hersh, P.S.2
  • 4
    • 0033898907 scopus 로고    scopus 로고
    • The cornea is not a piece of plastic
    • Roberts C. The cornea is not a piece of plastic. J Refract Surg. 2000;16:407-413.
    • (2000) J Refract Surg , vol.16 , pp. 407-413
    • Roberts, C.1
  • 5
    • 34548038404 scopus 로고    scopus 로고
    • Analysis of ectasia after laser in situ keratomileusis: Risk factors
    • Binder PS. Analysis of ectasia after laser in situ keratomileusis: risk factors. J Cataract Refract Surg. 2007;33:1530-1538.
    • (2007) J Cataract Refract Surg , vol.33 , pp. 1530-1538
    • Binder, P.S.1
  • 6
    • 0021035876 scopus 로고
    • Evaluation and comparison of sources of variability in the measurement of corneal thickness with ultrasonic and optical pachymeters
    • Salz JJ, Azen SP, Berstein J, Caroline P, Villasenor RA, Schanzlin DJ. Evaluation and comparison of sources of variability in the measurement of corneal thickness with ultrasonic and optical pachymeters. Ophthalmic Surg. 1983;14:750-754.
    • (1983) Ophthalmic Surg , vol.14 , pp. 750-754
    • Salz, J.J.1    Azen, S.P.2    Berstein, J.3    Caroline, P.4    Villasenor, R.A.5    Schanzlin, D.J.6
  • 7
    • 28044436542 scopus 로고    scopus 로고
    • Agreement and repeatability of central thickness measurement in normal corneas using ultrasound pachymetry and the OCULUS Pentacam
    • O'Donnell C, Maldonado-Codina C. Agreement and repeatability of central thickness measurement in normal corneas using ultrasound pachymetry and the OCULUS Pentacam. Cornea. 2005;24:920-924.
    • (2005) Cornea , vol.24 , pp. 920-924
    • O'Donnell, C.1    Maldonado-Codina, C.2
  • 8
    • 0037500421 scopus 로고    scopus 로고
    • Intraoperative optical coherence pachymetry during laser in situ keratomileusis - first clinical experience
    • Wirbelauer C, Pham DT. Intraoperative optical coherence pachymetry during laser in situ keratomileusis - first clinical experience. J Refract Surg. 2003;19:372-377.
    • (2003) J Refract Surg , vol.19 , pp. 372-377
    • Wirbelauer, C.1    Pham, D.T.2
  • 9
    • 0025356549 scopus 로고
    • Imaging characteristics of three cameras using the Scheimpflug principle
    • Kojima M, Wegener A, Hockwin O. Imaging characteristics of three cameras using the Scheimpflug principle. Ophthalmic Res. 1990;1:29-35.
    • (1990) Ophthalmic Res , vol.1 , pp. 29-35
    • Kojima, M.1    Wegener, A.2    Hockwin, O.3
  • 10
    • 0036189248 scopus 로고    scopus 로고
    • Spot size and quality of scanning laser correction of higher-order wavefront aberrations
    • Huang D, Arif M. Spot size and quality of scanning laser correction of higher-order wavefront aberrations. J Cataract Refract Surg. 2002;28:407-416.
    • (2002) J Cataract Refract Surg , vol.28 , pp. 407-416
    • Huang, D.1    Arif, M.2
  • 11
    • 0037242027 scopus 로고    scopus 로고
    • Effect of beam size on the expected benefit of customized laser refractive surgery
    • Guirao A, Williams D, MacRae S. Effect of beam size on the expected benefit of customized laser refractive surgery. J Refract Surg. 2003;19:15-23.
    • (2003) J Refract Surg , vol.19 , pp. 15-23
    • Guirao, A.1    Williams, D.2    MacRae, S.3
  • 12
    • 12444321995 scopus 로고    scopus 로고
    • Simulation of eye-tracker latency, spot size, and ablation pulse depth on the correction of higher order wavefront aberrations with scanning spot laser systems
    • Bueeler M, Mrochen M. Simulation of eye-tracker latency, spot size, and ablation pulse depth on the correction of higher order wavefront aberrations with scanning spot laser systems. J Refract Surg. 2005;21:28-36.
    • (2005) J Refract Surg , vol.21 , pp. 28-36
    • Bueeler, M.1    Mrochen, M.2
  • 13
    • 3042586618 scopus 로고    scopus 로고
    • Accuracy and precision of objective refraction from wavefront aberrations
    • Thibos LN, Hong X, Bradley A, Applegate RA. Accuracy and precision of objective refraction from wavefront aberrations. J Vis. 2004;23:329-351.
    • (2004) J Vis , vol.23 , pp. 329-351
    • Thibos, L.N.1    Hong, X.2    Bradley, A.3    Applegate, R.A.4
  • 15
    • 0036743484 scopus 로고    scopus 로고
    • VSIA Standards Taskforce Members. Vision science and its applications. Standards for reporting the optical aberrations of eyes
    • Thibos LN, Applegate RA, Schwiegerling JT, Webb R; VSIA Standards Taskforce Members. Vision science and its applications. Standards for reporting the optical aberrations of eyes. J Refract Surg. 2002;18:S652-S660.
    • (2002) J Refract Surg , vol.18
    • Thibos, L.N.1    Applegate, R.A.2    Schwiegerling, J.T.3    Webb, R.4
  • 16
    • 33750459039 scopus 로고    scopus 로고
    • I have tested for you. Pachymetry devices [French]
    • Borderie V. I have tested for you. Pachymetry devices [French]. J Fr Ophtalmol. 2006;29:40-44.
    • (2006) J Fr Ophtalmol , vol.29 , pp. 40-44
    • Borderie, V.1
  • 17
    • 11144314293 scopus 로고    scopus 로고
    • Continuous monitoring of corneal thickness changes during LASIK with online optical coherence pachymetry
    • Wirbelauer C, Pham DT. Continuous monitoring of corneal thickness changes during LASIK with online optical coherence pachymetry. J Cataract Refract Surg. 2004;30:2559-2568.
    • (2004) J Cataract Refract Surg , vol.30 , pp. 2559-2568
    • Wirbelauer, C.1    Pham, D.T.2
  • 19
    • 34249302029 scopus 로고    scopus 로고
    • Online optical coherence pachymetry to evaluate intraoperative ablation parameters in LASIK
    • Wirbelauer C, Aurich H, Pham DT. Online optical coherence pachymetry to evaluate intraoperative ablation parameters in LASIK. Graefes Arch Clin Exp Ophthalmol. 2007;245:775-781.
    • (2007) Graefes Arch Clin Exp Ophthalmol , vol.245 , pp. 775-781
    • Wirbelauer, C.1    Aurich, H.2    Pham, D.T.3
  • 20
    • 10744231521 scopus 로고    scopus 로고
    • Online optical coherence pachymetry in laser in situ keratomileusis
    • Wirbelauer C, Haberle H, Pham DT. Online optical coherence pachymetry in laser in situ keratomileusis. Ophthalmologe. 2004;101:140-145.
    • (2004) Ophthalmologe , vol.101 , pp. 140-145
    • Wirbelauer, C.1    Haberle, H.2    Pham, D.T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.