메뉴 건너뛰기




Volumn , Issue , 2009, Pages 164-168

Triangulation and 3D location estimation of RFI and partial discharge sources within a 400kV substation

Author keywords

[No Author keywords available]

Indexed keywords

3D POSITIONS; BROADBAND MOBILE; JOINT AREA; LOCATION ESTIMATION; PARTIAL DISCHARGE SOURCES; RADIO FREQUENCY INTERFERENCE; RF SOURCES; SOURCE LOCATION; SPECIFIC LOCATION; TIME-DIFFERENCES;

EID: 70449652320     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/EIC.2009.5166337     Document Type: Conference Paper
Times cited : (19)

References (9)
  • 1
    • 0027794865 scopus 로고
    • RFI measurements as a diagnostic technique for medium voltage transformers
    • Canterbury, pp
    • P. Pakonen, A. Lehtio, K. Kannus and E. Lakervi, "RFI measurements as a diagnostic technique for medium voltage transformers", Int. Conf. on Partial Discharges, Canterbury, pp. 115-116, 1993.
    • (1993) Int. Conf. on Partial Discharges , pp. 115-116
    • Pakonen, P.1    Lehtio, A.2    Kannus, K.3    Lakervi, E.4
  • 2
    • 0031125961 scopus 로고    scopus 로고
    • Power Line RF Interference-Sounds, patterns, and myths
    • Vo
    • M.O. Loftness, "Power Line RF Interference-Sounds, patterns, and myths", IEEE Trans. on Power Delivery, Vo. 12, No. 2, pp. 934-940, 1997.
    • (1997) IEEE Trans. on Power Delivery , vol.12 , Issue.2 , pp. 934-940
    • Loftness, M.O.1
  • 3
    • 0006429158 scopus 로고    scopus 로고
    • Electromagnetic noise spectrum caused by partial discharge in air at high voltage substations
    • M. Hikita et al., "Electromagnetic noise spectrum caused by partial discharge in air at high voltage substations", IEEE Trans. on power Delivery, Vol. 13, No. 2, pp. 434-439, 1998
    • (1998) IEEE Trans. on power Delivery , vol.13 , Issue.2 , pp. 434-439
    • Hikita, M.1
  • 4
    • 23944440123 scopus 로고    scopus 로고
    • Radiometric location of partial discharge sources on energized high-voltage plant
    • P.J. Moore, I. Portugues and I.A. Glover, "Radiometric location of partial discharge sources on energized high-voltage plant", IEEE Transactions on Power Delivery, vol. 20(3), pp. 2264-2272, 2005.
    • (2005) IEEE Transactions on Power Delivery , vol.20 , Issue.3 , pp. 2264-2272
    • Moore, P.J.1    Portugues, I.2    Glover, I.A.3
  • 5
    • 33244460023 scopus 로고    scopus 로고
    • Partial discharge investigation of a power transformer using wireless wideband radio-frequency measurements
    • P.J. Moore, I.E. Portugues and I.A. Glover, "Partial discharge investigation of a power transformer using wireless wideband radio-frequency measurements", IEEE Trans. on Power Delivery, Vol. 21, No. 1, pp. 528-530, 2006
    • (2006) IEEE Trans. on Power Delivery , vol.21 , Issue.1 , pp. 528-530
    • Moore, P.J.1    Portugues, I.E.2    Glover, I.A.3
  • 6
    • 0036693153 scopus 로고    scopus 로고
    • Applying UHF partial discharge detection to power transformers
    • M.D. Judd et al., "Applying UHF partial discharge detection to power transformers", IEEE Power Eng. Rev., pp. 57-59, 2002.
    • (2002) IEEE Power Eng. Rev , pp. 57-59
    • Judd, M.D.1
  • 7
    • 4243096278 scopus 로고    scopus 로고
    • Location of partial discharges in power transformers using computer-aided acoustic techniques
    • L. Tang, Z. Wu, H. Li, and D. Nie, "Location of partial discharges in power transformers using computer-aided acoustic techniques", Can. J. Elect. & Comp. Eng., 21, (2), pp. 67-71, 1996
    • (1996) Can. J. Elect. & Comp. Eng , vol.21 , Issue.2 , pp. 67-71
    • Tang, L.1    Wu, Z.2    Li, H.3    Nie, D.4
  • 8
    • 0033890678 scopus 로고    scopus 로고
    • PD detection and localisation by acoustic measurements in an oil-filled transformer
    • Y. Lu, X. Tan and X. Hu, "PD detection and localisation by acoustic measurements in an oil-filled transformer", IEE Proc-Sci. Meas. Technol, Vol. 147 (2), pp. 81-85, 2000.
    • (2000) IEE Proc-Sci. Meas. Technol , vol.147 , Issue.2 , pp. 81-85
    • Lu, Y.1    Tan, X.2    Hu, X.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.