Volumn 40, Issue 1, 2010, Pages 137-145

Electrical Resistance Tomography imaging of concrete

Author keywords

Concrete (E); Crack detection (B); Electrical properties (C); Non destructive testing

Indexed keywords

AIR VOIDS; ALTERNATING CURRENT; BOUNDARY MEASUREMENTS; CONCRETE IMAGING; CONDUCTIVITY DISTRIBUTIONS; ELECTRICAL MEASUREMENT; ELECTRICAL PROPERTY; ELECTRICAL RESISTANCE TOMOGRAPHY; MATRIX; METALLIC PHASIS; MOISTURE GRADIENT; NON DESTRUCTIVE EVALUATION; NON DESTRUCTIVE TESTING; REINFORCING BAR; TARGET SURFACE; THREE DIMENSIONAL IMAGING;

EID: 70449646206     PISSN: 00088846     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.cemconres.2009.08.023     Document Type: Article
Times cited : (211)

References (48)
  • 1
    • 0038481520 scopus 로고    scopus 로고
    • Electrical resistivity measurement applied to cracking assessment on reinforced concrete structures in civil engineering
    • Lataste J.F., Sirieix C., Breysse D., and Frappa M. Electrical resistivity measurement applied to cracking assessment on reinforced concrete structures in civil engineering. NDT & E International 36 (2003) 383-394
    • (2003) NDT & E International , vol.36 , pp. 383-394
    • Lataste, J.F.1    Sirieix, C.2    Breysse, D.3    Frappa, M.4
  • 2
    • 0035412988 scopus 로고    scopus 로고
    • Electrical impedance spectra to monitor damage during tensile loading of cement composites
    • Peled A., Torrents J.M., Mason T.O., Shah S.P., and Garboczi E.J. Electrical impedance spectra to monitor damage during tensile loading of cement composites. ACI Materials Journal 98 (2001) 313-322
    • (2001) ACI Materials Journal , vol.98 , pp. 313-322
    • Peled, A.1    Torrents, J.M.2    Mason, T.O.3    Shah, S.P.4    Garboczi, E.J.5
  • 3
    • 33845444391 scopus 로고    scopus 로고
    • Monitoring fiber dispersion in fiber-reinforced cementitious materials: comparison of AC-impedance spectroscopy and image analysis
    • Ozyurt N., Woo L.Y., Mason T.O., and Shah S.P. Monitoring fiber dispersion in fiber-reinforced cementitious materials: comparison of AC-impedance spectroscopy and image analysis. ACI Materials Journal 103 (2006) 340-347
    • (2006) ACI Materials Journal , vol.103 , pp. 340-347
    • Ozyurt, N.1    Woo, L.Y.2    Mason, T.O.3    Shah, S.P.4
  • 4
    • 33751509924 scopus 로고    scopus 로고
    • Combined time domain reflectometry and AC-impedance spectroscopy of fiber-reinforced fresh-cement composites
    • Woo L.Y., Kidner N.J., Wansom S., and Mason T.O. Combined time domain reflectometry and AC-impedance spectroscopy of fiber-reinforced fresh-cement composites. Cement and Concrete Research 37 (2007) 89-95
    • (2007) Cement and Concrete Research , vol.37 , pp. 89-95
    • Woo, L.Y.1    Kidner, N.J.2    Wansom, S.3    Mason, T.O.4
  • 5
    • 33748887790 scopus 로고    scopus 로고
    • Non-destructive monitoring of fiber orientation using AC-IS: an industrial-scale application
    • Ozyurt N., Mason T.O., and Shah S.P. Non-destructive monitoring of fiber orientation using AC-IS: an industrial-scale application. Cement and Concrete Research 36 (2006) 1653-1660
    • (2006) Cement and Concrete Research , vol.36 , pp. 1653-1660
    • Ozyurt, N.1    Mason, T.O.2    Shah, S.P.3
  • 6
    • 0032203642 scopus 로고    scopus 로고
    • Nondestructive measurement of corrosion state of reinforcing steel in concrete
    • Monteiro P.J.M., Morrison F., and Frangos W. Nondestructive measurement of corrosion state of reinforcing steel in concrete. ACI Materials Journal 95 (1998) 704-709
    • (1998) ACI Materials Journal , vol.95 , pp. 704-709
    • Monteiro, P.J.M.1    Morrison, F.2    Frangos, W.3
  • 7
    • 0035297206 scopus 로고    scopus 로고
    • Noninvasive surface measurement of corrosion impedance of reinforcing bar in concrete - part 1: experimental results
    • Zhang J., Monteiro P.J.M., and Morrison H.F. Noninvasive surface measurement of corrosion impedance of reinforcing bar in concrete - part 1: experimental results. ACI Materials Journal 98 (2001) 116-125
    • (2001) ACI Materials Journal , vol.98 , pp. 116-125
    • Zhang, J.1    Monteiro, P.J.M.2    Morrison, H.F.3
  • 8
    • 0036590567 scopus 로고    scopus 로고
    • Noninvasive surface measurement of corrosion impedance of reinforcing bar in concrete - part 2: forward modeling
    • Zhang J., Monteiro P.J.M., and Morrison H.F. Noninvasive surface measurement of corrosion impedance of reinforcing bar in concrete - part 2: forward modeling. ACI Materials Journal 99 (2002) 242-249
    • (2002) ACI Materials Journal , vol.99 , pp. 242-249
    • Zhang, J.1    Monteiro, P.J.M.2    Morrison, H.F.3
  • 9
    • 4544265356 scopus 로고    scopus 로고
    • Surface measurement of corrosion of reinforcing bar in concrete - 3: effect of geometry and material properties
    • Zhang J., Monteiro P.J.M., Morrison H.F., and Mancio M. Surface measurement of corrosion of reinforcing bar in concrete - 3: effect of geometry and material properties. ACI Materials Journal 101 (2004) 273-280
    • (2004) ACI Materials Journal , vol.101 , pp. 273-280
    • Zhang, J.1    Monteiro, P.J.M.2    Morrison, H.F.3    Mancio, M.4
  • 10
    • 0024768617 scopus 로고
    • Dependence of electrical impedance of cement-based materials on their moisture condition
    • McCarter W.J., and Garvin S. Dependence of electrical impedance of cement-based materials on their moisture condition. Journal of Physics D: Applied Physics 22 (1989) 1773-1776
    • (1989) Journal of Physics D: Applied Physics , vol.22 , pp. 1773-1776
    • McCarter, W.J.1    Garvin, S.2
  • 11
    • 0030644697 scopus 로고    scopus 로고
    • Monitoring of repaired reinforced concrete structures by means of resistivity measurements
    • Hunkeler F. Monitoring of repaired reinforced concrete structures by means of resistivity measurements. Materials Science Forum (Switzerland) 247 (1997) 93-106
    • (1997) Materials Science Forum (Switzerland) , vol.247 , pp. 93-106
    • Hunkeler, F.1
  • 12
    • 0032048193 scopus 로고    scopus 로고
    • AC impedance profiling within cover zone concrete: influence of water and ionic ingress
    • McCarter W.J., and Ezirim H. AC impedance profiling within cover zone concrete: influence of water and ionic ingress. Advances in cement research 10 1998 (1998) 57-66
    • (1998) Advances in cement research , vol.10 , Issue.1998 , pp. 57-66
    • McCarter, W.J.1    Ezirim, H.2
  • 13
    • 24644497622 scopus 로고    scopus 로고
    • Influence of the migration of chloride ions on the electrochemical impedance spectroscopy of mortar paste
    • Loche J.M., Ammar A., and Dumargue P. Influence of the migration of chloride ions on the electrochemical impedance spectroscopy of mortar paste. Cement and Concrete Research 35 (2005) 1797-1803
    • (2005) Cement and Concrete Research , vol.35 , pp. 1797-1803
    • Loche, J.M.1    Ammar, A.2    Dumargue, P.3
  • 19
    • 67649295347 scopus 로고    scopus 로고
    • Electrical Impedance Tomographic methods for sensing strain fields and crack damage in cementitious structures
    • 10.1177/1045389X08096052
    • Hou T.-C., and Lynch J.P. Electrical Impedance Tomographic methods for sensing strain fields and crack damage in cementitious structures. Journal of Intelligent Material Systems and Structures 00 (2008) 10.1177/1045389X08096052
    • (2008) Journal of Intelligent Material Systems and Structures , vol.0
    • Hou, T.-C.1    Lynch, J.P.2
  • 23
    • 0026907944 scopus 로고
    • Existence and uniqueness for electrode models for electric current computed tomography
    • Somersalo E., Cheney M., and Isaacson D. Existence and uniqueness for electrode models for electric current computed tomography. SIAM Journal on Applied Mathematics 52 (1992) 1023-1040
    • (1992) SIAM Journal on Applied Mathematics , vol.52 , pp. 1023-1040
    • Somersalo, E.1    Cheney, M.2    Isaacson, D.3
  • 25
    • 33748749612 scopus 로고    scopus 로고
    • Statistical inverse problems: discretization, model reduction and inverse crimes
    • Kaipio J.P., and Somersalo E. Statistical inverse problems: discretization, model reduction and inverse crimes. Journal of Computational and Applied Mathematics 198 (2007) 493-504
    • (2007) Journal of Computational and Applied Mathematics , vol.198 , pp. 493-504
    • Kaipio, J.P.1    Somersalo, E.2
  • 26
    • 0036991819 scopus 로고    scopus 로고
    • Simultaneous reconstruction of electrode contact impedances and internal electrical properties, part I: theory
    • Vilhunen T., Kaipio J.P., Vauhkonen P.J., Savolainen T., and Vauhkonen M. Simultaneous reconstruction of electrode contact impedances and internal electrical properties, part I: theory. Measurement Science & Technology 13 (2002) 1848-1854
    • (2002) Measurement Science & Technology , vol.13 , pp. 1848-1854
    • Vilhunen, T.1    Kaipio, J.P.2    Vauhkonen, P.J.3    Savolainen, T.4    Vauhkonen, M.5
  • 28
    • 84890326874 scopus 로고
    • A technique for the numerical solution of certain integral equations of the {Thorn}rst kind
    • Phillips D.L. A technique for the numerical solution of certain integral equations of the {Thorn}rst kind. Journal of the Association for Computing Machinery 9 (1962) 84-97
    • (1962) Journal of the Association for Computing Machinery , vol.9 , pp. 84-97
    • Phillips, D.L.1
  • 30
    • 0001341095 scopus 로고
    • An image-enhancement technique for Electrical Impedance Tomography
    • Dobson D.C., and Santosa F. An image-enhancement technique for Electrical Impedance Tomography. Inverse Problems 10 (1994) 317-334
    • (1994) Inverse Problems , vol.10 , pp. 317-334
    • Dobson, D.C.1    Santosa, F.2
  • 31
    • 0034292512 scopus 로고    scopus 로고
    • Statistical inversion and Monte Carlo sampling methods in Electrical Impedance Tomography
    • Kaipio J.P., Kolehmainen V., Somersalo E., and Vauhkonen M. Statistical inversion and Monte Carlo sampling methods in Electrical Impedance Tomography. Inverse Problems 16 (2000) 1487-1522
    • (2000) Inverse Problems , vol.16 , pp. 1487-1522
    • Kaipio, J.P.1    Kolehmainen, V.2    Somersalo, E.3    Vauhkonen, M.4
  • 33
    • 0032729509 scopus 로고    scopus 로고
    • A reconstruction algorithm for Electrical Impedance Tomography data collected on rectangular electrode arrays
    • Mueller J., Isaacson D., and Newell J.C. A reconstruction algorithm for Electrical Impedance Tomography data collected on rectangular electrode arrays. IEEE Transactions in Biomedical Engineering 46 (1999) 1379-1386
    • (1999) IEEE Transactions in Biomedical Engineering , vol.46 , pp. 1379-1386
    • Mueller, J.1    Isaacson, D.2    Newell, J.C.3
  • 37
    • 0003982971 scopus 로고    scopus 로고
    • Springer Series in Operations Research, Springer, New York
    • Nocedal J., and Wright S.J. Numerical Optimization (1999), Springer Series in Operations Research, Springer, New York
    • (1999) Numerical Optimization
    • Nocedal, J.1    Wright, S.J.2
  • 42
    • 0035283448 scopus 로고    scopus 로고
    • Test methods for on site measurement of resistivity of concrete - a RILEM TC-154 technical recommendation
    • Polder R.B. Test methods for on site measurement of resistivity of concrete - a RILEM TC-154 technical recommendation. Construction and Building Materials 15 (2001) 125-131
    • (2001) Construction and Building Materials , vol.15 , pp. 125-131
    • Polder, R.B.1
  • 45
    • 34447624297 scopus 로고    scopus 로고
    • Mineshaft imaging using surface and crosshole 3D electricalresistivity tomography: a case history from the East Pennine Coalfield, UK
    • Chambers J.E., Wilkinson P.B., Weller A.L., Meldrum P.I., Ogilvy R.D., and Caunt S. Mineshaft imaging using surface and crosshole 3D electricalresistivity tomography: a case history from the East Pennine Coalfield, UK. Journal of Applied Geophysics 62 (2007) 324-337
    • (2007) Journal of Applied Geophysics , vol.62 , pp. 324-337
    • Chambers, J.E.1    Wilkinson, P.B.2    Weller, A.L.3    Meldrum, P.I.4    Ogilvy, R.D.5    Caunt, S.6
  • 46
    • 34547123124 scopus 로고    scopus 로고
    • Subsurface electrical imaging of anisotropic formations affected by a slow active reverse fault, Provence, France
    • Nguyen F., Garambois S., Chardon D., Hermitte D., Bellier O., and Jongmans D. Subsurface electrical imaging of anisotropic formations affected by a slow active reverse fault, Provence, France. Journal of Applied Geophysics 62 (2007) 338-353
    • (2007) Journal of Applied Geophysics , vol.62 , pp. 338-353
    • Nguyen, F.1    Garambois, S.2    Chardon, D.3    Hermitte, D.4    Bellier, O.5    Jongmans, D.6
  • 47
    • 67349177155 scopus 로고    scopus 로고
    • Electrical resistivity tomography and statistical analysis in landslide modelling: a conceptual approach
    • 10.1016/j.jappgeo.2008.10.014
    • Piegari E., Cataudella V., Di Maio R., Milano L., Nicodemi M., and Soldovier M.G. Electrical resistivity tomography and statistical analysis in landslide modelling: a conceptual approach. Journal of Applied Geophysics (2009) 10.1016/j.jappgeo.2008.10.014
    • (2009) Journal of Applied Geophysics
    • Piegari, E.1    Cataudella, V.2    Di Maio, R.3    Milano, L.4    Nicodemi, M.5    Soldovier, M.G.6