메뉴 건너뛰기




Volumn , Issue , 2009, Pages 425-429

Form wound stator insulation system under different voltage waveform stresses

Author keywords

[No Author keywords available]

Indexed keywords

ELECTRICAL STRESS; EXPONENTIAL DECAYS; FFT ANALYSIS; FORM WOUND; FORM WOUND STATOR COILS; HIGHER HARMONICS; HIGHER TEMPERATURES; INFRARED IMAGES; INSULATION SYSTEM; MAXIMUM TEMPERATURE RISE; OUTPUT VOLTAGES; PEAK VALUES; POWER FREQUENCY; PULSED VOLTAGES; SINUSOIDAL PULSE; SINUSOIDAL VOLTAGE; SQUARE WAVES; STATOR INSULATION SYSTEMS; TEMPERATURE RISE; VOLTAGE SOURCE CONVERTERS; VOLTAGE WAVEFORMS; WAVE FORMS; WAVE STRESS;

EID: 70449627635     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/EIC.2009.5166384     Document Type: Conference Paper
Times cited : (5)

References (10)
  • 2
    • 0030110724 scopus 로고    scopus 로고
    • Analysis of the impact of pulse-width modulated inverter voltage waveforms on AC induction motors
    • March/April
    • Austin H. Bonnett, "Analysis of the impact of pulse-width modulated inverter voltage waveforms on AC induction motors" IEEE Transactions on Industry Applications, Vol. 32, NO. 2, March/April 1996
    • (1996) IEEE Transactions on Industry Applications , vol.32 , Issue.2
    • Bonnett, A.H.1
  • 3
    • 0030247001 scopus 로고    scopus 로고
    • Failure mechanism of the inter-turn insulation of low voltage electric machines fed by pulse-controlled inverters
    • September/October
    • M. Kaufhold, G. Borner, M. Eberhardt, and J. Speck, "Failure mechanism of the inter-turn insulation of low voltage electric machines fed by pulse-controlled inverters" IEEE Electrical Magazine, September/October 1996 Vol. 12, NO. 5
    • (1996) IEEE Electrical Magazine , vol.12 , Issue.5
    • Kaufhold, M.1    Borner, G.2    Eberhardt, M.3    Speck, J.4
  • 4
    • 0029345812 scopus 로고
    • Implications for the Application of Adjustable speed drive electronics to Motor Stator Winding Insulation
    • July/August
    • J.A. Oliver, G.C. Stone, "Implications for the Application of Adjustable speed drive electronics to Motor Stator Winding Insulation" IEEE Electrical Magazine, July/August 1995 Vol. 11, NO. 4
    • (1995) IEEE Electrical Magazine , vol.11 , Issue.4
    • Oliver, J.A.1    Stone, G.C.2
  • 6
    • 29244491474 scopus 로고    scopus 로고
    • Effectiveness of Stress Grading Coatings on Form Wound Stator Coil Groundwall Insulation under Fast Rise Time Pulse Voltages
    • Dec
    • Fermin P. Espino-Cortes, Edward A. Cherney, Shesha H Jayaram, "Effectiveness of Stress Grading Coatings on Form Wound Stator Coil Groundwall Insulation under Fast Rise Time Pulse Voltages", IEEE Trans. On Energy Conversion, Vol. 20, pp. 844-851, Dec.2005
    • (2005) IEEE Trans. On Energy Conversion , vol.20 , pp. 844-851
    • Espino-Cortes, F.P.1    Cherney, E.A.2    Jayaram, S.H.3
  • 7
    • 62949123666 scopus 로고    scopus 로고
    • Turn insulation aging of motors exposed to fast pulses of inverter drives
    • 25 Sept
    • C. Hudon, J.N. Seguin, N. Amyot, "Turn insulation aging of motors exposed to fast pulses of inverter drives", Digital Object Identifier, 22-25 Sept.1997
    • (1997) Digital Object Identifier , vol.22
    • Hudon, C.1    Seguin, J.N.2    Amyot, N.3
  • 8
    • 0031276106 scopus 로고    scopus 로고
    • Failure Mechanism of Winding Insulations in Inverted-Fed motors
    • Y. Weijun, "Failure Mechanism of Winding Insulations in Inverted-Fed motors", IEEE Electrical Insulation Magazine, pp. 18-23, 1997.
    • (1997) IEEE Electrical Insulation Magazine , pp. 18-23
    • Weijun, Y.1
  • 9
    • 70449674895 scopus 로고    scopus 로고
    • Emad Sharifi, Edward. A. Cherney, Shesha H. Jayaram Anisotropic Dielectric properties of Stress Grading Materials in Medium Voltage Form-Wound Motor Coils to Study Thermal Effects of Repetitive Fast Pulses EIC 2009
    • Emad Sharifi, Edward. A. Cherney, Shesha H. Jayaram "Anisotropic Dielectric properties of Stress Grading Materials in Medium Voltage Form-Wound Motor Coils to Study Thermal Effects of Repetitive Fast Pulses" EIC 2009
  • 10
    • 15944426554 scopus 로고    scopus 로고
    • Qualification and Acceptance Test for Type 11 Electrical Insulation Systems Used In Rotating Electrical Machines Fed from Voltage Converters
    • IEC 60034-18-42
    • IEC 60034-18-42, "Qualification and Acceptance Test for Type 11 Electrical Insulation Systems Used In Rotating Electrical Machines Fed from Voltage Converters"


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.