메뉴 건너뛰기




Volumn 72, Issue 3, 2009, Pages 483-488

Heartbeat-related displacement of the thoracic aorta in patients with chronic aortic dissection type B: Quantification by dynamic CTA

Author keywords

Aorta; Aortic dissection; Computed tomography angiography; Endovascular aortic repair

Indexed keywords

AORTIC ARCH; AORTIC DISSECTION; AORTIC WALLS; BREATH-HOLD; COMPUTED TOMOGRAPHY ANGIOGRAPHY; ENDOVASCULAR; IN-PLANE; MEAN DISPLACEMENT; MULTIPLANAR REFORMATION; REGION OF INTEREST; SLICE THICKNESS; THORACIC AORTA; TIME INSTANCES; TRACTION FORCES; UNBALANCED DISTRIBUTION;

EID: 70449624091     PISSN: 0720048X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ejrad.2008.07.045     Document Type: Article
Times cited : (21)

References (25)
  • 1
    • 0021332547 scopus 로고
    • Risk factors for aortic dissection: a necropsy study of 161 cases
    • Larson E.W., and Edwards W.D. Risk factors for aortic dissection: a necropsy study of 161 cases. Am J Cardiol 53 6 (1984) 849-855
    • (1984) Am J Cardiol , vol.53 , Issue.6 , pp. 849-855
    • Larson, E.W.1    Edwards, W.D.2
  • 2
    • 10744231927 scopus 로고    scopus 로고
    • Characterizing the young patient with aortic dissection: results from the International Registry of Aortic Dissection (IRAD)
    • Januzzi J.L., Isselbacher E.M., Fattori R., et al. Characterizing the young patient with aortic dissection: results from the International Registry of Aortic Dissection (IRAD). J Am Coll Cardiol 43 4 (2004) 665-669
    • (2004) J Am Coll Cardiol , vol.43 , Issue.4 , pp. 665-669
    • Januzzi, J.L.1    Isselbacher, E.M.2    Fattori, R.3
  • 3
    • 33746368014 scopus 로고    scopus 로고
    • Stress analysis in a layered aortic arch model under pulsatile blood flow
    • Gao F., Watanabe M., and Matsuzawa T. Stress analysis in a layered aortic arch model under pulsatile blood flow. Biomed Eng Online (2006) 525
    • (2006) Biomed Eng Online , pp. 525
    • Gao, F.1    Watanabe, M.2    Matsuzawa, T.3
  • 4
    • 39749132177 scopus 로고    scopus 로고
    • Finite element modeling of the thoracic aorta: including aortic root motion to evaluate the risk of aortic dissection
    • Beller C.J., Labrosse M.R., Thubrikar M.J., and Robicsek F. Finite element modeling of the thoracic aorta: including aortic root motion to evaluate the risk of aortic dissection. J Med Eng Technol 32 2 (2008) 167-170
    • (2008) J Med Eng Technol , vol.32 , Issue.2 , pp. 167-170
    • Beller, C.J.1    Labrosse, M.R.2    Thubrikar, M.J.3    Robicsek, F.4
  • 5
    • 24644515456 scopus 로고    scopus 로고
    • Mechanical deterioration underlies malignant behavior of aneurysmal human ascending aorta
    • Koullias G., Modak R., Tranquilli M., et al. Mechanical deterioration underlies malignant behavior of aneurysmal human ascending aorta. J Thorac Cardiovasc Surg 130 3 (2005) 677-683
    • (2005) J Thorac Cardiovasc Surg , vol.130 , Issue.3 , pp. 677-683
    • Koullias, G.1    Modak, R.2    Tranquilli, M.3
  • 6
    • 0344838501 scopus 로고    scopus 로고
    • Endovascular treatment of complicated type-B aortic dissection with stent-grafts: midterm results
    • Lopera J., Patino J.H., Urbina C., et al. Endovascular treatment of complicated type-B aortic dissection with stent-grafts: midterm results. J Vasc Interv Radiol 14 2 Pt 1 (2003) 195-203
    • (2003) J Vasc Interv Radiol , vol.14 , Issue.2 PART 1 , pp. 195-203
    • Lopera, J.1    Patino, J.H.2    Urbina, C.3
  • 7
    • 33746228337 scopus 로고    scopus 로고
    • Complications after endovascular repair of acute symptomatic and chronic expanding Stanford type B aortic dissections
    • Böckler D., Schumacher H., Ganten M., et al. Complications after endovascular repair of acute symptomatic and chronic expanding Stanford type B aortic dissections. J Thorac Cardiovasc Surg 132 2 (2006) 361-368
    • (2006) J Thorac Cardiovasc Surg , vol.132 , Issue.2 , pp. 361-368
    • Böckler, D.1    Schumacher, H.2    Ganten, M.3
  • 8
    • 34250222773 scopus 로고    scopus 로고
    • Thoracic aortic stent-graft devices: problems, failure modes, and applicability
    • Nienaber C.A., Kische S., and Ince H. Thoracic aortic stent-graft devices: problems, failure modes, and applicability. Semin Vasc Surg 20 2 (2007) 81-89
    • (2007) Semin Vasc Surg , vol.20 , Issue.2 , pp. 81-89
    • Nienaber, C.A.1    Kische, S.2    Ince, H.3
  • 9
    • 70350469657 scopus 로고    scopus 로고
    • Assessment of thoracic aortic conformational changes by fourdimensional computed tomography angiography in patients with chronic aortic dissection type b
    • Jul 22 [Epub ahead of print
    • Weber TF, Ganten M, Böckler D, et al. Assessment of thoracic aortic conformational changes by fourdimensional computed tomography angiography in patients with chronic aortic dissection type b. Eur Radiol 2008 Jul 22 [Epub ahead of print].
    • (2008) Eur Radiol
    • Weber, T.F.1    Ganten, M.2    Böckler, D.3
  • 10
    • 1242336791 scopus 로고    scopus 로고
    • Role of aortic root motion in the pathogenesis of aortic dissection
    • Beller C.J., Labrosse M.R., Thubrikar M.J., and Robicsek F. Role of aortic root motion in the pathogenesis of aortic dissection. Circulation 109 6 (2004) 763-769
    • (2004) Circulation , vol.109 , Issue.6 , pp. 763-769
    • Beller, C.J.1    Labrosse, M.R.2    Thubrikar, M.J.3    Robicsek, F.4
  • 11
    • 33747698457 scopus 로고    scopus 로고
    • Comparison between aortic annulus motion and mitral annulus motion obtained using echocardiography
    • Emilsson K., Egerlid R., and Nygren B.M. Comparison between aortic annulus motion and mitral annulus motion obtained using echocardiography. Clin Physiol Funct Imaging 26 5 (2006) 257-262
    • (2006) Clin Physiol Funct Imaging , vol.26 , Issue.5 , pp. 257-262
    • Emilsson, K.1    Egerlid, R.2    Nygren, B.M.3
  • 12
    • 34848827207 scopus 로고    scopus 로고
    • Toward endografting of the ascending aorta: insight into dynamics using dynamic cine-CTA
    • van Prehn J., Vincken K.L., Muhs B.E., et al. Toward endografting of the ascending aorta: insight into dynamics using dynamic cine-CTA. J Endovasc Ther 14 4 (2007) 551-560
    • (2007) J Endovasc Ther , vol.14 , Issue.4 , pp. 551-560
    • van Prehn, J.1    Vincken, K.L.2    Muhs, B.E.3
  • 13
    • 67349199015 scopus 로고    scopus 로고
    • Motion characterization of aortic wall and intimal flap by ECG-gated CT in patients with chronic B-dissection
    • Aug 2 [Epub ahead of print
    • Ganten M, Weber TF, von Tengg-Kobligk H, et al. Motion characterization of aortic wall and intimal flap by ECG-gated CT in patients with chronic B-dissection. Eur J Radiol 2008 Aug 2 [Epub ahead of print].
    • (2008) Eur J Radiol
    • Ganten, M.1    Weber, T.F.2    von Tengg-Kobligk, H.3
  • 14
    • 31544469238 scopus 로고    scopus 로고
    • Quantification of aortic elasticity: development and experimental validation of a method using computed tomography
    • Ganten M., Boese J.M., Leitermann D., and Semmler W. Quantification of aortic elasticity: development and experimental validation of a method using computed tomography. Eur Radiol 15 12 (2005) 2506-2512
    • (2005) Eur Radiol , vol.15 , Issue.12 , pp. 2506-2512
    • Ganten, M.1    Boese, J.M.2    Leitermann, D.3    Semmler, W.4
  • 15
    • 33846998663 scopus 로고    scopus 로고
    • Age related changes of human aortic distensibility: evaluation with ECG-gated CT
    • Ganten M., Krautter U., Hosch W., et al. Age related changes of human aortic distensibility: evaluation with ECG-gated CT. Eur Radiol 17 3 (2007) 701-708
    • (2007) Eur Radiol , vol.17 , Issue.3 , pp. 701-708
    • Ganten, M.1    Krautter, U.2    Hosch, W.3
  • 16
    • 0343114488 scopus 로고    scopus 로고
    • True-lumen collapse in aortic dissection: part I. Evaluation of causative factors in phantoms with pulsatile flow
    • Chung J.W., Elkins C., Sakai T., et al. True-lumen collapse in aortic dissection: part I. Evaluation of causative factors in phantoms with pulsatile flow. Radiology 214 1 (2000) 87-98
    • (2000) Radiology , vol.214 , Issue.1 , pp. 87-98
    • Chung, J.W.1    Elkins, C.2    Sakai, T.3
  • 17
    • 0343114487 scopus 로고    scopus 로고
    • True-lumen collapse in aortic dissection: part II. Evaluation of treatment methods in phantoms with pulsatile flow
    • Chung J.W., Elkins C., Sakai T., et al. True-lumen collapse in aortic dissection: part II. Evaluation of treatment methods in phantoms with pulsatile flow. Radiology 214 1 (2000) 99-106
    • (2000) Radiology , vol.214 , Issue.1 , pp. 99-106
    • Chung, J.W.1    Elkins, C.2    Sakai, T.3
  • 18
    • 0043056861 scopus 로고    scopus 로고
    • Endovascular aortic arch reconstruction with supra-aortic transposition for symptomatic contained rupture and dissection: early experience in 8 high-risk patients
    • Schumacher H., Böckler D., Bardenheuer H., Hansmann J., and Allenberg J.R. Endovascular aortic arch reconstruction with supra-aortic transposition for symptomatic contained rupture and dissection: early experience in 8 high-risk patients. J Endovasc Ther 10 6 (2003) 1066-1074
    • (2003) J Endovasc Ther , vol.10 , Issue.6 , pp. 1066-1074
    • Schumacher, H.1    Böckler, D.2    Bardenheuer, H.3    Hansmann, J.4    Allenberg, J.R.5
  • 19
    • 33750687299 scopus 로고    scopus 로고
    • Hybrid aortic procedures for endoluminal arch replacement in thoracic aneurysms and type B dissections
    • Schumacher H., Von Tengg-Kobligk H., Ostovic M., et al. Hybrid aortic procedures for endoluminal arch replacement in thoracic aneurysms and type B dissections. J Cardiovasc Surg (Torino) 47 5 (2006) 509-517
    • (2006) J Cardiovasc Surg (Torino) , vol.47 , Issue.5 , pp. 509-517
    • Schumacher, H.1    Von Tengg-Kobligk, H.2    Ostovic, M.3
  • 20
    • 0032712192 scopus 로고    scopus 로고
    • Heart motion adapted cine phase-contrast flow measurements through the aortic valve
    • Kozerke S., Scheidegger M.B., Pedersen E.M., and Boesiger P. Heart motion adapted cine phase-contrast flow measurements through the aortic valve. Magn Reson Med 42 5 (1999) 970-978
    • (1999) Magn Reson Med , vol.42 , Issue.5 , pp. 970-978
    • Kozerke, S.1    Scheidegger, M.B.2    Pedersen, E.M.3    Boesiger, P.4
  • 21
    • 0017126404 scopus 로고
    • The influence of left ventricular stroke volume on aortic root motion: an echocardiographic study
    • Pratt R.C., Parisi A.F., Harrington J.J., and Sasahara A.A. The influence of left ventricular stroke volume on aortic root motion: an echocardiographic study. Circulation 53 6 (1976) 947-953
    • (1976) Circulation , vol.53 , Issue.6 , pp. 947-953
    • Pratt, R.C.1    Parisi, A.F.2    Harrington, J.J.3    Sasahara, A.A.4
  • 22
    • 0041761119 scopus 로고    scopus 로고
    • Acceptable short-term results after endovascular repair of diseases of the thoracic aorta in high risk patients
    • Krohg-Sorensen K., Hafsahl G., Fosse E., and Geiran O.R. Acceptable short-term results after endovascular repair of diseases of the thoracic aorta in high risk patients. Eur J Cardiothorac Surg 24 3 (2003) 379-387
    • (2003) Eur J Cardiothorac Surg , vol.24 , Issue.3 , pp. 379-387
    • Krohg-Sorensen, K.1    Hafsahl, G.2    Fosse, E.3    Geiran, O.R.4
  • 23
    • 34248674181 scopus 로고    scopus 로고
    • Stent-graft versus open-surgical repair of the thoracic aorta: mid-term results
    • Stone D.H., Brewster D.C., Kwolek C.J., et al. Stent-graft versus open-surgical repair of the thoracic aorta: mid-term results. J Vasc Surg 44 6 (2006) 1188-1197
    • (2006) J Vasc Surg , vol.44 , Issue.6 , pp. 1188-1197
    • Stone, D.H.1    Brewster, D.C.2    Kwolek, C.J.3
  • 24
    • 13644263268 scopus 로고    scopus 로고
    • Late surgical conversion after thoracic endograft failure due to fracture of the longitudinal support wire
    • Böckler D., von Tengg-Kobligk H., Schumacher H., et al. Late surgical conversion after thoracic endograft failure due to fracture of the longitudinal support wire. J Endovasc Ther 12 1 (2005) 98-102
    • (2005) J Endovasc Ther , vol.12 , Issue.1 , pp. 98-102
    • Böckler, D.1    von Tengg-Kobligk, H.2    Schumacher, H.3
  • 25
    • 18744401962 scopus 로고    scopus 로고
    • Images in vascular medicine. Postprocessing 'fly-through' of multislice computed tomography after thoracic endografting
    • Böckler D., Allenberg J.R., Kauczor H.U., and von Tengg-Kobligk H. Images in vascular medicine. Postprocessing 'fly-through' of multislice computed tomography after thoracic endografting. Vasc Med 10 1 (2005) 61-62
    • (2005) Vasc Med , vol.10 , Issue.1 , pp. 61-62
    • Böckler, D.1    Allenberg, J.R.2    Kauczor, H.U.3    von Tengg-Kobligk, H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.