-
1
-
-
0037030658
-
A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization
-
Morice MC, Serruys PW, Sousa JE, et al. A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization. N Engl J Med 2002; 346: 1773-1780
-
(2002)
N Engl J Med
, vol.346
, pp. 1773-1780
-
-
Morice, M.C.1
Serruys, P.W.2
Sousa, J.E.3
-
2
-
-
24644477492
-
Comparison of a polymer-based paclitaxel-eluting stent with a bare metal stent in patients with complex coronary artery disease: A randomized controlled trial
-
DOI 10.1001/jama.294.10.1215
-
Stone GW, Ellis SG, Cannon L, et al. Comparison of a polymer-based paclitaxel-eluting stent with a bare metal stent in patients with complex coronary artery disease: a randomized controlled trial. JAMA 2005; 294: 1215-1223 (Pubitemid 41352109)
-
(2005)
Journal of the American Medical Association
, vol.294
, Issue.10
, pp. 1215-1223
-
-
Stone, G.W.1
Ellis, S.G.2
Cannon, L.3
Mann, J.T.4
Greenberg, J.D.5
Spriggs, D.6
O'Shaughnessy, C.D.7
Demaio, S.8
Hall, P.9
Popma, J.J.10
Koglin, J.11
Russell, M.E.12
-
3
-
-
33847705701
-
Stent thrombosis in randomized clinical trials of drug-eluting stents
-
DOI 10.1056/NEJMoa067731
-
Mauri L, Hsieh WH, Massaro JM, Ho KK, D'Agostino R, Cutlip DE. Stent thrombosis in randomized clinical trials of drug-eluting stents. N Engl J Med 2007; 356: 1020-1029 (Pubitemid 46376802)
-
(2007)
New England Journal of Medicine
, vol.356
, Issue.10
, pp. 1020-1029
-
-
Mauri, L.1
Hsieh, W.-H.2
Massaro, J.M.3
Ho, K.K.L.4
D'Agostino, R.5
Cutlip, D.E.6
-
4
-
-
17844373254
-
Incidence, predictors, and outcome of thrombosis after successful implantation of drug-eluting stents
-
lakovou I, Schmidt T, Bonizzoni E, et al. Incidence, predictors, and outcome of thrombosis after successful implantation of drug-eluting stents. JAMA 2005; 293: 2126-2130
-
(2005)
JAMA
, vol.293
, pp. 2126-2130
-
-
Lakovou, I.1
Schmidt, T.2
Bonizzoni, E.3
-
5
-
-
33846828736
-
Prevention of Premature Discontinuation of Dual Antiplatelet Therapy in Patients with Coronary Artery Stents. a Science Advisory from the American Heart Association, American College of Cardiology, Society for Cardiovascular Angiography and Interventions, American College of Surgeons, and American Dental Association
-
DOI 10.1016/j.jacc.2007.01.003, PII S073510970700054X
-
Grines CL, Bonow RO, Casey DE Jr, et al. Prevention of premature discontinuation of dual antiplatelet therapy in patients with coronary artery stents: a science advisory from the American Heart Association, American College of Cardiology, Society for Cardiovascular Angiography and Interventions, American College of Surgeons, and American Dental Association, with representation from the American College of Physicians. J Am Coll Cardiol 2007; 49: 734-739 (Pubitemid 46210116)
-
(2007)
Journal of the American College of Cardiology
, vol.49
, Issue.6
, pp. 734-739
-
-
Grines, C.L.1
Bonow, R.O.2
Casey Jr., D.E.3
Gardner, T.J.4
Lockhart, P.B.5
Moliterno, D.J.6
O'Gara, P.7
Whitlow, P.8
-
6
-
-
57549083305
-
Clinical characteristics of stent fracture after sirolimus-eluting stent implantation
-
Yang TH, Kim DI, Park SG, et al. Clinical characteristics of stent fracture after sirolimus-eluting stent implantation. Int J Cardiol 2009; 131: 212-216
-
(2009)
Int J Cardiol
, vol.131
, pp. 212-216
-
-
Yang, T.H.1
Kim, D.I.2
Park, S.G.3
-
7
-
-
33746213944
-
Drug-eluting stent strut fracture as a cause of restenosis
-
Bae JH, Hyun DW, Kim KY, Yoon HJ, Nakamura S. Drug-eluting stent strut fracture as a cause of restenosis. Korean Circ J 2005; 35: 787-789
-
(2005)
Korean Circ J
, vol.35
, pp. 787-789
-
-
Bae, J.H.1
Hyun, D.W.2
Kim, K.Y.3
Yoon, H.J.4
Nakamura, S.5
-
8
-
-
0346732102
-
Stent Fracture and Restenosis in the Drug-Eluting Stent Era
-
DOI 10.1002/ccd.10709
-
S) Sianos G, Hofma S, Ligthart JM, et al. Stent fracture and restenosis in the drug-eluting stent era. Catheter Cardiovasc Interv 2004; 61: 111-116 (Pubitemid 38036800)
-
(2004)
Catheterization and Cardiovascular Interventions
, vol.61
, Issue.1
, pp. 111-116
-
-
Sianos, G.1
Hofma, S.2
Ligthart, J.M.R.3
Saia, F.4
Hoye, A.5
Lemos, P.A.6
Serruys, P.W.7
-
9
-
-
0029837889
-
Patterns and mechanisms of in-stent restenosis: A serial intravascular ultrasound study
-
Hoffmann R, Mintz GS, Dussaillant GR, et al. Patterns and mechanisms of in-stent restenosis: a serial intravascular ultrasound study. Circulation 1996; 94: 1247-1254 (Pubitemid 26307249)
-
(1996)
Circulation
, vol.94
, Issue.6
, pp. 1247-1254
-
-
Hoffmann, R.1
Mintz, G.S.2
Dussaillant, G.R.3
Popma, J.J.4
Pichard, A.D.5
Satler, L.F.6
Kent, K.M.7
Griffin, J.8
Leon, M.B.9
-
10
-
-
34247282702
-
Predictive factors for restenosis after drug-eluting stent implantation
-
Lee CW, Park SJ. Predictive factors for restenosis after drug-eluting stent implantation. Korean Circ J 2007; 37: 97-102. (Pubitemid 46624766)
-
(2007)
Korean Circulation Journal
, vol.37
, Issue.3
, pp. 97-102
-
-
Cheol, W.L.1
Park, S.-J.2
-
11
-
-
0033564883
-
Influence of lesion length on restenosis after coronary stent placement
-
DOI 10.1016/S0002-9149(99)00165-4, PII S0002914999001654
-
Kastrati A, Elezi S, Dirschinger J, Hadamitzky M, Neumann FJ, Schomig A. Influence of lesion length on restenosis after coronary stent placement. Am J Cardiol 1999; 83: 1617-1622 (Pubitemid 29288003)
-
(1999)
American Journal of Cardiology
, vol.83
, Issue.12
, pp. 1617-1622
-
-
Kastrati, A.1
Elezi, S.2
Dirschinger, J.3
Hadamitzky, M.4
Neumann, F.-J.5
Schomig, A.6
-
12
-
-
0343852702
-
Predictive factors of restenosis after coronary stent placement
-
DOI 10.1016/S0735-1097(97)00334-3, PII S0735109797003343
-
Kastrati A, Schomig A, Elezi S, et al. Predictive factors of restenosis after coronary stent placement. J Am Coll Cardiol 1997; 30: 1428-1436 (Pubitemid 27486458)
-
(1997)
Journal of the American College of Cardiology
, vol.30
, Issue.6
, pp. 1428-1436
-
-
Kastrati, A.1
Schomig, A.2
Elezi, S.3
Schuhlen, H.4
Dirschinger, J.5
Hadamitzky, M.6
Wehinger, A.7
Hausleiter, J.8
Walter, H.9
Neumann, F.-J.10
-
13
-
-
0032480806
-
Vessel size and long-term outcome after coronary stent placement
-
Elezi S, Kastrati A, Neumann FJ, Hadamitzky M, Dirschinger J, Schomig A. Vessel size and long-term outcome after coronary stent placement. Circulation 1998; 98: 1875-1880 (Pubitemid 28509283)
-
(1998)
Circulation
, vol.98
, Issue.18
, pp. 1875-1880
-
-
Elezi, S.1
Kastrati, A.2
Neumann, F.-J.3
Hadamitzky, M.4
Dirschinger, J.5
Schomig, A.6
-
14
-
-
0031909566
-
Intravascular ultrasound predictors of angiographics restenosis in lesions treated with Palmaz-Schatz stents
-
DOI 10.1016/S0735-1097(97)00438-5, PII S0735109797004385
-
Hoffmann R, Mintz GS, Mehran R, et al. Intravascular ultrasound predictors of angiographic restenosis in lesions treated with Palmaz-Schatz stents. J Am Coll Cardiol 1998; 31: 43-49 (Pubitemid 28064720)
-
(1998)
Journal of the American College of Cardiology
, vol.31
, Issue.1
, pp. 43-49
-
-
Hoffmann, R.1
Mintz, G.S.2
Mehran, R.3
Pichard, A.D.4
Kent, K.M.5
Satler, L.F.6
Popma, J.J.7
Hongsheng, W.8
Leon, M.B.9
-
15
-
-
0030962358
-
Frequency and outcome of development of coronary artery aneurysm after intracoronary stent placement and angioplasty
-
DOI 10.1016/S0002-9149(97)00055-6, PII S0002914997000556
-
Slota PA, Fischman DL, Savage MP, Rake R, Goldberg S. Frequency and outcome of development of coronary artery aneurysm after intracoronary stent placement and angioplasty. STRESS Trial Investigators. Am J Cardiol 1997; 79: 1104-1106 (Pubitemid 27217068)
-
(1997)
American Journal of Cardiology
, vol.79
, Issue.8
, pp. 1104-1106
-
-
Slota, P.A.1
Fischman, D.L.2
Savage, M.P.3
Rake, R.4
Goldberg, S.5
-
16
-
-
0038241919
-
Regional remodeling as the cause of late stent malapposition
-
Mintz GS, Shah VM, Weissman NJ. Regional remodeling as the cause of late stent malapposition. Circulation 2003; 107: 2660-2663
-
(2003)
Circulation
, vol.107
, pp. 2660-2663
-
-
Mintz, G.S.1
Shah, V.M.2
Weissman, N.J.3
-
17
-
-
10744229988
-
Localized hypersensitivity and late coronary thrombosis secondary to a sirolimus-eluting stent: Should we be cautious?
-
Virmani R, Guagliumi G, Farb A, et al. Localized hypersensitivity and late coronary thrombosis secondary to a sirolimus-eluting stent: should we be cautious? Circulation 2004; 109: 701-705
-
(2004)
Circulation
, vol.109
, pp. 701-705
-
-
Virmani, R.1
Guagliumi, G.2
Farb, A.3
-
18
-
-
33847032996
-
Development of coronary aneurysm after drug-eluting stent implantation
-
Bavry AA, Chiu JH, Jefferson BK, et al. Development of coronary aneurysm after drug-eluting stent implantation. Ann Intern Med 2007; 146: 230-232 (Pubitemid 351650642)
-
(2007)
Annals of Internal Medicine
, vol.146
, Issue.3
, pp. 230-232
-
-
Bavry, A.A.1
Chiu, J.H.2
Jefferson, B.K.3
Karha, J.4
Bhatt, D.L.5
Ellis, S.G.6
Whitlow, P.L.7
-
19
-
-
53549124983
-
Spontaneous resolution of multiple coronary aneurysms complicating drug eluting stent implantation
-
Gurvitch R, Yan BP, Warren R, Marasco S, Black AJ, Ajani AE. Spontaneous resolution of multiple coronary aneurysms complicating drug eluting stent implantation. Int J Cardiol 2008; 130: e7-10.
-
(2008)
Int J Cardiol
, vol.130
-
-
Gurvitch, R.1
Yan, B.P.2
Warren, R.3
Marasco, S.4
Black, A.J.5
Ajani, A.E.6
|