메뉴 건너뛰기




Volumn 35, Issue 4, 2009, Pages 232-237

Simulation-based analysis of the resolution and SNR properties of partial k-space EPI

Author keywords

Echo planar imaging; MRI; Pulse sequence; Resolution; Signal to noise ratio

Indexed keywords


EID: 70449562638     PISSN: 15525031     EISSN: 1552504X     Source Type: Journal    
DOI: 10.1002/cmr.b.20147     Document Type: Article
Times cited : (17)

References (10)
  • 3
    • 9444231681 scopus 로고    scopus 로고
    • Some new observations on pulse sequence dependent diffusion related edge enhancement in MR microscopy
    • Cho ZH, Hong IK, Ro YM. 1996. Some new observations on pulse sequence dependent diffusion related edge enhancement in MR microscopy. Magn Reson Med 36:197-203.
    • (1996) Magn Reson Med , vol.36 , pp. 197-203
    • Cho, Z.H.1    Hong, I.K.2    Ro, Y.M.3
  • 5
    • 0034839919 scopus 로고    scopus 로고
    • Spiral-in/out BOLD fMR for increased SNR and reduced susceptibility artifacts
    • Glover GH, Law CS. 2001. Spiral-in/out BOLD fMR for increased SNR and reduced susceptibility artifacts. Magn Reson Med 46:515-522.
    • (2001) Magn Reson Med , vol.46 , pp. 515-522
    • Glover, G.H.1    Law, C.S.2
  • 6
    • 0028969854 scopus 로고
    • Susceptibility magnetic resonance imaging using spectral decomposition
    • Ro YM, Cho ZH. 1995. Susceptibility magnetic resonance imaging using spectral decomposition. Magn Reson Med 33:521-528.
    • (1995) Magn Reson Med , vol.33 , pp. 521-528
    • Ro, Y.M.1    Cho, Z.H.2
  • 7
    • 0242290944 scopus 로고    scopus 로고
    • Parsing local signal evolution directly from a single-shot MRI signal: A new approach for fMRI
    • Twieg DB. 2003. Parsing local signal evolution directly from a single-shot MRI signal: a new approach for fMRI. Magn Reson Med 50:1043-1052.
    • (2003) Magn Reson Med , vol.50 , pp. 1043-1052
    • Twieg, D.B.1
  • 9
    • 0008302356 scopus 로고
    • High speed, high resolution, spin echo imaging by Mosaic scan and MESH
    • Rzedzian R. 1987. High speed, high resolution, spin echo imaging by Mosaic scan and MESH. Soc Magn Reson Med. 6th Annual Meeting abstr. 51.2.
    • (1987) Soc Magn Reson Med. 6th Annual Meeting abstr , vol.51 , pp. 2
    • Rzedzian, R.1
  • 10
    • 0026500406 scopus 로고
    • Reduction of susceptibility artifact in gradient-echo imaging
    • Cho ZH, Ro YM. 1992. Reduction of susceptibility artifact in gradient-echo imaging. Magn Reson Med 23:193-200.
    • (1992) Magn Reson Med , vol.23 , pp. 193-200
    • Cho, Z.H.1    Ro, Y.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.