-
2
-
-
33645819613
-
Hydrogen peroxide tooth-whitening (bleaching) products: Review of adverse effects and safety issues
-
Tredwin CJ, Naik S, Lewis NJ, Scully C (2006) Hydrogen peroxide tooth-whitening (bleaching) products: review of adverse effects and safety issues. Br Dent J 200:371-376.
-
(2006)
Br Dent J
, vol.200
, pp. 371-376
-
-
Tredwin, C.J.1
Naik, S.2
Lewis, N.J.3
Scully, C.4
-
3
-
-
0000978508
-
Oxo[5, 10, 15, 20-Tetra(4-Pyridyl)Porphyrinato]Titanium(Iv) - an ultra-high sensitivity spectrophotometric reagent for hydrogen-peroxide
-
Matsubara C, Kawamoto N, Takamura K (1992) Oxo[5, 10, 15, 20-Tetra(4-Pyridyl)Porphyrinato]Titanium(Iv) - an ultra-high sensitivity spectrophotometric reagent for hydrogen-peroxide. Analyst 117:1781-1784.
-
(1992)
Analyst
, vol.117
, pp. 1781-1784
-
-
Matsubara, C.1
Kawamoto, N.2
Takamura, K.3
-
4
-
-
33744983724
-
Peroxidase immobilized on Amberlite Ira-743 resin for on-line spectrophotometric detection of hydrogen peroxide in rainwater
-
Matos RC, Coelho EO, de Souza CF, Guedes FA, Matos MA (2006) Peroxidase immobilized on Amberlite Ira-743 resin for on-line spectrophotometric detection of hydrogen peroxide in rainwater. Talanta 69:1208-1214.
-
(2006)
Talanta
, vol.69
, pp. 1208-1214
-
-
Matos, R.C.1
Coelho, E.O.2
de Souza, C.F.3
Guedes, F.A.4
Matos, M.A.5
-
5
-
-
9644273757
-
A selective, cell-permeable optical probe for hydrogen peroxide in living cells
-
Chang MCY, Pralle A, Isacoff EY, Chang CJ (2004) A selective, cell-permeable optical probe for hydrogen peroxide in living cells. J Am Chem Soc 126:15392-15393.
-
(2004)
J Am Chem Soc
, vol.126
, pp. 15392-15393
-
-
Chang, M.C.Y.1
Pralle, A.2
Isacoff, E.Y.3
Chang, C.J.4
-
6
-
-
0033395849
-
Fluorometric determination of hydrogen peroxide in natural water samples by flow injection analysis with a reaction column of peroxidase immobilized onto chitosan beads
-
Taniai T, Sakuragawa A, Okutani T (1999) Fluorometric determination of hydrogen peroxide in natural water samples by flow injection analysis with a reaction column of peroxidase immobilized onto chitosan beads. Anal. Sci. 15:1077-1082.
-
(1999)
Anal. Sci.
, vol.15
, pp. 1077-1082
-
-
Taniai, T.1
Sakuragawa, A.2
Okutani, T.3
-
7
-
-
0024839854
-
Amperometric flow-injection technique for determination of hydrogen-peroxide and sulfur(Iv) in atmospheric liquid water
-
Gutz IGR, Klockow D (1989) Amperometric flow-injection technique for determination of hydrogen-peroxide and sulfur(Iv) in atmospheric liquid water. Fresenius Zeitschrift Fur Analytische Chemie 335:919-923.
-
(1989)
Fresenius Zeitschrift Fur Analytische Chemie
, vol.335
, pp. 919-923
-
-
Gutz, I.G.R.1
Klockow, D.2
-
8
-
-
23044437622
-
Sensor and biosensor preparation, optimisation and applications of Prussian blue modified electrodes
-
Ricci F, Palleschi G (2005) Sensor and biosensor preparation, optimisation and applications of Prussian blue modified electrodes. Biosens Bioelectron 21:389-407.
-
(2005)
Biosens Bioelectron
, vol.21
, pp. 389-407
-
-
Ricci, F.1
Palleschi, G.2
-
9
-
-
84996298155
-
Peroxyoxalate chemiluminescence assay of hydrogen-peroxide and glucose using 2, 4, 6, 8-Tetrathiomorpholinopyrimido[5, 4-D]-Pyrimidine as a fluorescent component
-
Nakashima K, Maki K, Kawaguchi S, Akiyama S, Tsukamoto Y, Imai K (1991) Peroxyoxalate chemiluminescence assay of hydrogen-peroxide and glucose using 2, 4, 6, 8-Tetrathiomorpholinopyrimido[5, 4-D]-Pyrimidine as a fluorescent component. Anal Sci 7:709-713.
-
(1991)
Anal Sci
, vol.7
, pp. 709-713
-
-
Nakashima, K.1
Maki, K.2
Kawaguchi, S.3
Akiyama, S.4
Tsukamoto, Y.5
Imai, K.6
-
10
-
-
33745112125
-
A new chemiluminescence sensor for hydrogen peroxide determination
-
Omanovic E, Kalcher K (2004) A new chemiluminescence sensor for hydrogen peroxide determination. Int J Environ Anal Chem 85:853-860.
-
(2004)
Int J Environ Anal Chem
, vol.85
, pp. 853-860
-
-
Omanovic, E.1
Kalcher, K.2
-
11
-
-
0020088539
-
Electrochemical and spectroscopic studies of metal hexacyanometalate films. 1. Cupric hexacyanoferrate
-
Siperko LM, Kuwana T (1983) Electrochemical and spectroscopic studies of metal hexacyanometalate films. 1. Cupric hexacyanoferrate. J Electrochem Soc 130:396-402.
-
(1983)
J Electrochem Soc
, vol.130
, pp. 396-402
-
-
Siperko, L.M.1
Kuwana, T.2
-
12
-
-
0034922653
-
Prussian blue and its analogues: Electrochemistry and analytical applications
-
Karyakin AA (2001) Prussian blue and its analogues: electrochemistry and analytical applications. Electroanalysis 13:813-819.
-
(2001)
Electroanalysis
, vol.13
, pp. 813-819
-
-
Karyakin, A.A.1
-
13
-
-
0000779648
-
Determination of hydrogen peroxide by utilizing a cobalt(Ii)hexacyanoferrate-modified glassy carbon electrode as a chemical sensor
-
Lin MS, Jan BI (1997) Determination of hydrogen peroxide by utilizing a cobalt(Ii)hexacyanoferrate-modified glassy carbon electrode as a chemical sensor. Electroanalysis 9:340-344.
-
(1997)
Electroanalysis
, vol.9
, pp. 340-344
-
-
Lin, M.S.1
Jan, B.I.2
-
14
-
-
0038637870
-
Electrocatalysis and Amperometric detection of hydrogen peroxide at an aluminum microelectrode modified with cobalt hexacyanoferrate film
-
Eftekhari A (2003) Electrocatalysis and Amperometric detection of hydrogen peroxide at an aluminum microelectrode modified with cobalt hexacyanoferrate film. Microchimica Acta 141:15-21.
-
(2003)
Microchimica Acta
, vol.141
, pp. 15-21
-
-
Eftekhari, A.1
-
15
-
-
54849433593
-
Hydrogen peroxide monitoring in photo-fenton reactions by using a metal hexacyanoferrate modified electrode
-
Salles MO, Paixão TRLC, Bertotti M (2007) Hydrogen peroxide monitoring in photo-fenton reactions by using a metal hexacyanoferrate modified electrode. Int J Electrochem Sci 2:248-256.
-
(2007)
Int J Electrochem Sci
, vol.2
, pp. 248-256
-
-
Salles, M.O.1
Paixão, T.R.L.C.2
Bertotti, M.3
-
16
-
-
54849423264
-
Ruthenium oxide hexacyanoferrate modified electrode for hydrogen peroxide detection
-
Paixão TRLC, Bertotti M (2008) Ruthenium oxide hexacyanoferrate modified electrode for hydrogen peroxide detection. Electroanalysis 20:1671-1677.
-
(2008)
Electroanalysis
, vol.20
, pp. 1671-1677
-
-
Paixão, T.R.L.C.1
Bertotti, M.2
-
18
-
-
17444419002
-
Preparation and characterization of ruthenium oxide/hexacyanoferrate and ruthenium hexacyanoferrate mixed films and their electrocatalytic properties
-
Chen SM, Lu MF, Lin KC (2005) Preparation and characterization of ruthenium oxide/hexacyanoferrate and ruthenium hexacyanoferrate mixed films and their electrocatalytic properties. J Electroanal Chem 579:163-174.
-
(2005)
J Electroanal Chem
, vol.579
, pp. 163-174
-
-
Chen, S.M.1
Lu, M.F.2
Lin, K.C.3
-
19
-
-
33845655682
-
Electrocatalytic oxidation of deoxyguanosine on a glassy carbon electrode modified with a ruthenium oxide hexacyanoferrate film
-
Paixão TRLC, Bertotti M (2007) Electrocatalytic oxidation of deoxyguanosine on a glassy carbon electrode modified with a ruthenium oxide hexacyanoferrate film. Electrochim Acta 52:2181-2188.
-
(2007)
Electrochim Acta
, vol.52
, pp. 2181-2188
-
-
Paixão, T.R.L.C.1
Bertotti, M.2
-
20
-
-
0021463364
-
Transport and kinetics in modified electrodes
-
Albery WJ, Hillman AR (1984) Transport and kinetics in modified electrodes. J Electroanal Chem 170:27-49.
-
(1984)
J Electroanal Chem
, vol.170
, pp. 27-49
-
-
Albery, W.J.1
Hillman, A.R.2
-
21
-
-
33845631637
-
Catalytic reduction of hydrogen peroxide at metal hexacyanoferrate composite electrodes and applications in enzymatic analysis
-
Gonzalez GLD, Kahlert H, Scholz F (2007) Catalytic reduction of hydrogen peroxide at metal hexacyanoferrate composite electrodes and applications in enzymatic analysis. Electrochim Acta 52:1968-1974.
-
(2007)
Electrochim Acta
, vol.52
, pp. 1968-1974
-
-
Gonzalez, G.L.D.1
Kahlert, H.2
Scholz, F.3
-
22
-
-
33847355117
-
Preparation, electrochemical behavior and performance of gallium hexacyanoferrate as electrocatalyst of H2o2
-
Yu H, Sheng QL, Bin Zheng J (2007) Preparation, electrochemical behavior and performance of gallium hexacyanoferrate as electrocatalyst of H2o2. Electrochim Acta 52:4403-4410.
-
(2007)
Electrochim Acta
, vol.52
, pp. 4403-4410
-
-
Yu, H.1
Sheng, Q.L.2
Bin Zheng, J.3
-
23
-
-
28844499536
-
A Fe3o4-based chemical sensor for cathodic determination of hydrogen peroxide
-
Lin MS, Len HJ (2005) A Fe3o4-based chemical sensor for cathodic determination of hydrogen peroxide. Electroanalysis 17:2068-2073.
-
(2005)
Electroanalysis
, vol.17
, pp. 2068-2073
-
-
Lin, M.S.1
Len, H.J.2
-
24
-
-
38349056863
-
Novel electrochemical microsensor for hydrogen peroxide based on iron-ruthenium hexacyanoferrate modified carbon fiber electrode
-
Pauliukaite R, Hocevar SB, Hutton EA, Ogorevc B (2008) Novel electrochemical microsensor for hydrogen peroxide based on iron-ruthenium hexacyanoferrate modified carbon fiber electrode. Electroanalysis 20:47-53.
-
(2008)
Electroanalysis
, vol.20
, pp. 47-53
-
-
Pauliukaite, R.1
Hocevar, S.B.2
Hutton, E.A.3
Ogorevc, B.4
|