메뉴 건너뛰기




Volumn 193, Issue 5, 2009, Pages 1296-1304

Normalized distance along the colon centerline: A method for correlating polyp location on CT colonography and optical colonoscopy

Author keywords

Colon polyp; Colorectal cancer screening; CT colonography; Optical colonoscopy

Indexed keywords

ARTICLE; CANCER SCREENING; CLINICAL ASSESSMENT; COLON; COLONOSCOPY; COMPARATIVE STUDY; COMPUTED TOMOGRAPHIC COLONOGRAPHY; CONTROLLED STUDY; CORRELATION ANALYSIS; DIAGNOSTIC ACCURACY; HUMAN; HUMAN CELL; HUMAN TISSUE; LINEAR REGRESSION ANALYSIS; MAJOR CLINICAL STUDY; MEASUREMENT; POLYP; PREDICTION AND FORECASTING; PRIORITY JOURNAL; STUDENT T TEST;

EID: 70449503671     PISSN: 0361803X     EISSN: None     Source Type: Journal    
DOI: 10.2214/AJR.09.2611     Document Type: Article
Times cited : (23)

References (15)
  • 1
    • 58949102421 scopus 로고    scopus 로고
    • CT colonography: Techniques and applications
    • Yee J. CT colonography: techniques and applications. Radiol Clin North Am 2009; 47:133-145
    • (2009) Radiol Clin North Am , vol.47 , pp. 133-145
    • Yee, J.1
  • 2
    • 33751350891 scopus 로고    scopus 로고
    • Current status of CT colonography
    • Frentz SM, Summers RM. Current status of CT colonography. Acad Radiol 2006; 13:1517-1531
    • (2006) Acad Radiol , vol.13 , pp. 1517-1531
    • Frentz, S.M.1    Summers, R.M.2
  • 3
    • 42949177399 scopus 로고    scopus 로고
    • Screening and surveillance for the early detection of colorectal cancer and adenomatous polyps, 2008: A joint guideline from the American Cancer Society, the US Multi-Society Task Force on Colorectal Cancer, and the American College of Radiology
    • DOI 10.3322/CA.2007.0018
    • Levin B, Lieberman DA, McFarland B, et al.; American Cancer Society Colorectal Cancer Advisory Group; US Multi-Society Task Force; American College of Radiology Colon Cancer Committee. Screening and surveillance for the early detection of colorectal cancer and adenomatous polyps, 2008: a joint guideline from the American Cancer Society, the US Multi-Society Task Force on Colorectal Cancer, and the American College of Radiology. CA Cancer J Clin 2008; 58:130-160 (Pubitemid 351830299)
    • (2008) CA Cancer Journal for Clinicians , vol.58 , Issue.3 , pp. 130-160
    • Levin, B.1    Lieberman, D.A.2    McFarland, B.3    Smith, R.A.4    Brooks, D.5    Andrews, K.S.6    Dash, C.7    Giardiello, F.M.8    Glick, S.9    Levin, T.R.10    Pickhardt, P.11    Rex, D.K.12    Thorson, A.13    Winawer, S.J.14
  • 4
    • 52249108133 scopus 로고    scopus 로고
    • Accuracy of CT colonography for detection of large adenomas and cancers
    • Johnson CD, Chen MH, Toledano AY, et al. Accuracy of CT colonography for detection of large adenomas and cancers. N Engl J Med 2008; 359:1207-1217
    • (2008) N Engl J Med , vol.359 , pp. 1207-1217
    • Johnson, C.D.1    Chen, M.H.2    Toledano, A.Y.3
  • 5
    • 20744456440 scopus 로고    scopus 로고
    • CT colonography reporting and data system: A consensus proposal
    • Zalis ME, Barish MA, Choi JR, et al. CT colonography reporting and data system: a consensus proposal. Radiology 2005; 236:3-9
    • (2005) Radiology , vol.236 , pp. 3-9
    • Zalis, M.E.1    Barish, M.A.2    Choi, J.R.3
  • 6
    • 34748840155 scopus 로고    scopus 로고
    • Anatomic factors predictive of incomplete colonoscopy based on findings at CT colonography
    • Hanson ME, Pickhardt PJ, Kim DH, Pfau PR. Anatomic factors predictive of incomplete colonoscopy based on findings at CT colonography. AJR 2007; 189:774-779
    • (2007) AJR , vol.189 , pp. 774-779
    • Hanson, M.E.1    Pickhardt, P.J.2    Kim, D.H.3    Pfau, P.R.4
  • 7
    • 0242268001 scopus 로고    scopus 로고
    • Automated Centerline for Computed Tomography Colonography
    • DOI 10.1016/S1076-6332(03)00464-1
    • Iordanescu G, Summers RM. Automated centerline for computed tomography colonography. Acad Radiol 2003; 10:1291-1301 (Pubitemid 37351902)
    • (2003) Academic Radiology , vol.10 , Issue.11 , pp. 1291-1301
    • Iordanescu, G.1    Summers, R.M.2
  • 9
    • 0041508688 scopus 로고    scopus 로고
    • Electronic cleansing and stool tagging in CT colonography: Advantages and pitfalls with primary three-dimensional evaluation
    • Pickhardt PJ, Choi JH. Electronic cleansing and stool tagging in CT colonography: advantages and pitfalls with primary three-dimensional evaluation. AJR 2003; 181:799-805
    • (2003) AJR , vol.181 , pp. 799-805
    • Pickhardt, P.J.1    Choi, J.H.2
  • 10
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • PII S0140673686908378
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 327:307-310 (Pubitemid 16134762)
    • (1986) Lancet , vol.1 , Issue.8476 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 13
  • 15
    • 34247470176 scopus 로고    scopus 로고
    • Teniae coli-based circumferential localization system for ct colonography: Feasibility study
    • DOI 10.1148/radiol.2432060353
    • Huang A, Roy DA, Summers RM, et al. Teniae coli-based circumferential localization system for CT colonography: feasibility study. Radiology 2007; 243:551-560 (Pubitemid 46649712)
    • (2007) Radiology , vol.243 , Issue.2 , pp. 551-560
    • Huang, A.1    Roy, D.A.2    Summers, R.M.3    Franaszek, M.4    Petrick, N.5    Choi, J.R.6    Pickhardt, P.J.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.