메뉴 건너뛰기




Volumn 2, Issue 11, 2009, Pages 1113-1115

Are Our Patients Better Off With Drug-Eluting Stents in Saphenous Vein Grafts?

Author keywords

coronary artery grafts; saphenous vein grafts; stents

Indexed keywords

BARE METAL STENT; CLINICAL TRIAL; CORONARY ARTERY BYPASS GRAFT; DEATH; DRUG ELUTING STENT; EDITORIAL; GRAFT FAILURE; GRAFT OCCLUSION; HEART INFARCTION; HUMAN; IN-STENT RESTENOSIS; INTERMETHOD COMPARISON; PATIENT SAFETY; PERCUTANEOUS CORONARY INTERVENTION; PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY; PRIORITY JOURNAL; REOPERATION; SAPHENOUS VEIN GRAFT; STENT THROMBOSIS; TREATMENT OUTCOME; VEIN GRAFT DISEASE;

EID: 70449490390     PISSN: 19368798     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jcin.2009.09.007     Document Type: Editorial
Times cited : (4)

References (12)
  • 1
    • 0018760094 scopus 로고
    • Nonoperative dilatation of coronary artery stenosis. Percutaneous transluminal coronary angioplasty
    • Gruentzig A.R., Senning A., and Siegenthaler W.E. Nonoperative dilatation of coronary artery stenosis. Percutaneous transluminal coronary angioplasty. N Engl J Med 301 (1979) 61-68
    • (1979) N Engl J Med , vol.301 , pp. 61-68
    • Gruentzig, A.R.1    Senning, A.2    Siegenthaler, W.E.3
  • 2
    • 0020619233 scopus 로고
    • Percutaneous transluminal coronary angioplasty in patients with prior coronary bypass surgery
    • Douglas J.S., Gruentzig A.R., King S.B., et al. Percutaneous transluminal coronary angioplasty in patients with prior coronary bypass surgery. J Am Coll Cardiol 2 (1983) 745-754
    • (1983) J Am Coll Cardiol , vol.2 , pp. 745-754
    • Douglas, J.S.1    Gruentzig, A.R.2    King, S.B.3
  • 3
    • 9844257578 scopus 로고    scopus 로고
    • Stent placement compared with balloon angioplasty for obstructed bypass grafts. Saphenous vein De Novo Trial Investigators
    • Savage M.P., Douglas Jr. J.S., Fischman D.L., et al. Stent placement compared with balloon angioplasty for obstructed bypass grafts. Saphenous vein De Novo Trial Investigators. N Engl J Med 337 (1997) 740-747
    • (1997) N Engl J Med , vol.337 , pp. 740-747
    • Savage, M.P.1    Douglas Jr., J.S.2    Fischman, D.L.3
  • 4
    • 70449486864 scopus 로고    scopus 로고
    • Outcomes with drug-eluting versus bare-metal stents in saphenous vein graft intervention: results from the STENT (Strategic Transcatheter Evaluation of New Therapies) Group
    • STENT Group
    • Brodie B.R., Wilson H., Stuckey T., et al., STENT Group. Outcomes with drug-eluting versus bare-metal stents in saphenous vein graft intervention: results from the STENT (Strategic Transcatheter Evaluation of New Therapies) Group. J Am Coll Cardiol Intv 2 (2009) 1105-1112
    • (2009) J Am Coll Cardiol Intv , vol.2 , pp. 1105-1112
    • Brodie, B.R.1    Wilson, H.2    Stuckey, T.3
  • 5
    • 33845410666 scopus 로고    scopus 로고
    • Randomized double-blind comparison of sirolimus-eluting stent versus bare-metal stent implantation in decreased saphenous vein grafts
    • Vermeersch P., Agostoni P., Verheye S., et al. Randomized double-blind comparison of sirolimus-eluting stent versus bare-metal stent implantation in decreased saphenous vein grafts. J Am Coll Cardiol 48 (2006) 2423-2431
    • (2006) J Am Coll Cardiol , vol.48 , pp. 2423-2431
    • Vermeersch, P.1    Agostoni, P.2    Verheye, S.3
  • 6
    • 34447120247 scopus 로고    scopus 로고
    • Increased late mortality after sirolimus-eluting stents versus bare-metal stents in diseased saphenous vein grafts
    • Vermeersch P., Agostoni P., Verheye S., et al. Increased late mortality after sirolimus-eluting stents versus bare-metal stents in diseased saphenous vein grafts. J Am Coll Cardiol 50 (2007) 261-267
    • (2007) J Am Coll Cardiol , vol.50 , pp. 261-267
    • Vermeersch, P.1    Agostoni, P.2    Verheye, S.3
  • 7
    • 47549089025 scopus 로고    scopus 로고
    • Late outcomes of drug-eluting versus bare-metal stents in saphenous vein grafts: propensity score analysis
    • Applegate R.J., Sacrinty M., Kutcher M., et al. Late outcomes of drug-eluting versus bare-metal stents in saphenous vein grafts: propensity score analysis. Catheter Cardiovasc Interv 72 (2008) 7-12
    • (2008) Catheter Cardiovasc Interv , vol.72 , pp. 7-12
    • Applegate, R.J.1    Sacrinty, M.2    Kutcher, M.3
  • 8
    • 61549089702 scopus 로고    scopus 로고
    • A randomized-controlled trial of a paclitaxel-eluting stent versus a similar bare-metal stent in saphenous vein graft lesions: the SOS (Stenting Of Saphenous vein grafts)
    • Brilakis E.S., Lichtenwalter C., de Lemos J.A., et al. A randomized-controlled trial of a paclitaxel-eluting stent versus a similar bare-metal stent in saphenous vein graft lesions: the SOS (Stenting Of Saphenous vein grafts). J Am Coll Cardiol 53 (2009) 919-928
    • (2009) J Am Coll Cardiol , vol.53 , pp. 919-928
    • Brilakis, E.S.1    Lichtenwalter, C.2    de Lemos, J.A.3
  • 9
    • 34547673494 scopus 로고    scopus 로고
    • Predictors of aorto-coronary saphenous vein bypass narrowing late after coronary artery bypass grafting
    • Rodes-Cabau J., Facta A., Larose E., et al. Predictors of aorto-coronary saphenous vein bypass narrowing late after coronary artery bypass grafting. Am J Cardiol 100 (2007) 640-645
    • (2007) Am J Cardiol , vol.100 , pp. 640-645
    • Rodes-Cabau, J.1    Facta, A.2    Larose, E.3
  • 10
    • 0030967488 scopus 로고    scopus 로고
    • Late myocardial ischemic events after saphenous vein graft intervention: importance of initially "non-significant" vein graft lesions
    • Ellis S.G., Brener S.J., DeLuca S., et al. Late myocardial ischemic events after saphenous vein graft intervention: importance of initially "non-significant" vein graft lesions. Am J Cardiol 79 (1997) 1460-1464
    • (1997) Am J Cardiol , vol.79 , pp. 1460-1464
    • Ellis, S.G.1    Brener, S.J.2    DeLuca, S.3
  • 11
  • 12
    • 47549119521 scopus 로고    scopus 로고
    • Parsing the subsets: when small studies create confusion
    • Blankenship J.C. Parsing the subsets: when small studies create confusion. Cathet Cardiovasc Interv 72 (2008) 23-24
    • (2008) Cathet Cardiovasc Interv , vol.72 , pp. 23-24
    • Blankenship, J.C.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.