메뉴 건너뛰기




Volumn , Issue , 2009, Pages 1215-1218

Hemodynamic alterations of a patient-specific intracranial aneurysm induced by virtual deployment of stents in various axial orientation

Author keywords

Aneurysm; Axial orientation; CFD; Hemodynamics; Stent

Indexed keywords

ANEURYSM; AXIAL ORIENTATION; AXIAL ORIENTATIONS; CFD; COMPLEX FLOW; COMPUTATIONAL HEMODYNAMICS; INTERNAL CAROTID ARTERY; INTRACRANIAL ANEURYSMS; SACCULAR ANEURYSM; STENT; STENTED ANEURYSM; STENTING; STRUT SIZE;

EID: 70449417580     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ISBI.2009.5193280     Document Type: Conference Paper
Times cited : (8)

References (11)
  • 2
    • 0035982808 scopus 로고    scopus 로고
    • Particle image velocimetry assessment of stent design influence on intra-aneurysmal flow
    • B.B. Lieber, V. Livescu, L.N. Hopkins, and A.K. Wakhloo, "Particle image velocimetry assessment of stent design influence on intra-aneurysmal flow," Ann Biomed Eng, vol. 30, no. 6, pp. 768-77, 2002.
    • (2002) Ann Biomed Eng , vol.30 , Issue.6 , pp. 768-777
    • Lieber, B.B.1    Livescu, V.2    Hopkins, L.N.3    Wakhloo, A.K.4
  • 3
    • 41549122258 scopus 로고    scopus 로고
    • Effects of stent porosity on hemodynamics in a sidewall aneurysm model
    • T.M. Liou and Y.C. Li, "Effects of stent porosity on hemodynamics in a sidewall aneurysm model," J Biomech, vol. 41, no. 6, pp. 1174-83, 2008.
    • (2008) J Biomech , vol.41 , Issue.6 , pp. 1174-1183
    • Liou, T.M.1    Li, Y.C.2
  • 4
    • 0036677287 scopus 로고    scopus 로고
    • Angiographic quantification of contrast medium washout from cerebral aneurysms after stent placement
    • C. Sadasivan, B.B. Lieber, M.J. Gounis, D.K. Lopes, and L.N. Hopkins, "Angiographic quantification of contrast medium washout from cerebral aneurysms after stent placement," AJNR Am J Neuroradiol, vol. 23, no. 7, pp. 1214-21, 2002.
    • (2002) AJNR Am J Neuroradiol , vol.23 , Issue.7 , pp. 1214-1221
    • Sadasivan, C.1    Lieber, B.B.2    Gounis, M.J.3    Lopes, D.K.4    Hopkins, L.N.5
  • 5
    • 3242713162 scopus 로고    scopus 로고
    • Finite-element modeling of the hemodynamics of stented aneurysms
    • G. R. Stuhne and D. A. Steinman, "Finite-element modeling of the hemodynamics of stented aneurysms," J Biomech Eng, vol. 126, no. 3, pp. 382-7, 2004.
    • (2004) J Biomech Eng , vol.126 , Issue.3 , pp. 382-387
    • Stuhne, G.R.1    Steinman, D.A.2
  • 6
    • 17444420835 scopus 로고    scopus 로고
    • Efficient simulation of blood flow past complex endovascular devices using an adaptive embedding technique
    • J. R. Cebral and R. Löhner, "Efficient simulation of blood flow past complex endovascular devices using an adaptive embedding technique," IEEE Trans Med Imaging, vol. 24, no. 4, pp. 468-76, 2005.
    • (2005) IEEE Trans Med Imaging , vol.24 , Issue.4 , pp. 468-476
    • Cebral, J.R.1    Löhner, R.2
  • 7
    • 79551684720 scopus 로고    scopus 로고
    • Fast virtual stenting with deformable meshes: Application to intracranial aneurysms, MICCAI08 - Part II -, vol
    • I. Larrabide, A. Radaelli, and A. Frangi, "Fast virtual stenting with deformable meshes: application to intracranial aneurysms," MICCAI08 - Part II -, vol. LNCS 5242, pp. 790-797, 2008.
    • (2008) LNCS , vol.5242 , pp. 790-797
    • Larrabide, I.1    Radaelli, A.2    Frangi, A.3
  • 8
    • 70449437713 scopus 로고    scopus 로고
    • Handbook of hydraulic resistance
    • New York
    • I. E Idelchik, "Handbook of hydraulic resistance," JAICO, New York, 2003.
    • (2003) JAICO
    • Idelchik, I.E.1
  • 9
    • 70449430071 scopus 로고    scopus 로고
    • Several stent struts increase blood flow speed in cerebral aneurysm
    • Ankara, Turkey
    • Toshio Nakayama and Makoto Ohta, "Several stent struts increase blood flow speed in cerebral aneurysm," International Intracranial Stent Symposium, Ankara, Turkey, 2008.
    • (2008) International Intracranial Stent Symposium
    • Nakayama, T.1    Ohta, M.2
  • 10
    • 0032858003 scopus 로고    scopus 로고
    • Adaptive remodeling of internal elastic lamina and endothelial lining during flow-induced arterial enlargement
    • H. Masuda, Y. J. Zhuang, T. M. Singh, K. Kawamura, M. Murakami, C. K. Zarins, and S. Glagov, "Adaptive remodeling of internal elastic lamina and endothelial lining during flow-induced arterial enlargement," Arterioscler Thromb Vasc Biol, vol. 19, no. 10, pp. 2298-307, 1999.
    • (1999) Arterioscler Thromb Vasc Biol , vol.19 , Issue.10 , pp. 2298-2307
    • Masuda, H.1    Zhuang, Y.J.2    Singh, T.M.3    Kawamura, K.4    Murakami, M.5    Zarins, C.K.6    Glagov, S.7
  • 11
    • 0024337945 scopus 로고
    • Etiology of intracranial berry aneurysms
    • W. E. Stehbens, "Etiology of intracranial berry aneurysms," J Neurosurg, vol. 70, no. 6, pp. 823-31, 1989.
    • (1989) J Neurosurg , vol.70 , Issue.6 , pp. 823-831
    • Stehbens, W.E.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.