Volumn 16, Issue 5, 2009, Pages 1462-1472

Detecting characteristics of various type antennas on partial discharge electromagnetic wave radiating through insulating spacer in gas insulated switchgear

Author keywords

Antenna; Externally leaking electromagnetic waves (EM waves); Gas insulated switchgear (GIS); High sensitivity; Partial discharge; Partial discharge detection sensor; Resonant frequency

Indexed keywords

EXTERNALLY LEAKING ELECTROMAGNETIC WAVES (EM-WAVES); GAS INSULATED SWITCHGEAR (GIS); HIGH SENSITIVITY; PARTIAL DISCHARGE DETECTION SENSOR; RESONANT FREQUENCY;

EID: 70449393162     PISSN: 10709878     EISSN: None     Source Type: Journal    
DOI: 10.1109/TDEI.2009.5293961     Document Type: Article
Times cited : (64)

References (14)
  • 3
    • 0030194832 scopus 로고    scopus 로고
    • GIS insulation co-ordination onsite tests and diagnostic techniques, a utility point of view
    • A. Sabot, A. Petit and J. P. Taillebois: "GIS insulation co-ordination onsite tests and diagnostic techniques, a utility point of view", IEEE Trans. Power Delivery, Vol.11, pp. 1301-1316, 1996.
    • (1996) IEEE Trans. Power Delivery , vol.11 , pp. 1301-1316
    • Sabot, A.1    Petit, A.2    Taillebois, J.P.3
  • 6
    • 0142001261 scopus 로고    scopus 로고
    • Resonance characteristics and identification of modes of electromagnetic wave excited by partial discharges in GIS
    • Japan, (in Japanese)
    • H. Muto, M. Doi, H. Fujii and M. Kamei, "Resonance characteristics and identification of modes of electromagnetic wave excited by partial discharges in GIS", Trans. IEE, Japan, Vol.118-B, No.12, pp. 1406-1414, 1998 (in Japanese).
    • (1998) Trans. IEE , vol.118 B , Issue.12 , pp. 1406-1414
    • Muto, H.1    Doi, M.2    Fujii, H.3    Kamei, M.4
  • 9
    • 0004099829 scopus 로고    scopus 로고
    • 3rd ed., John Wiley & Sons, Inc., ISBN: 0-471-32282-2
    • D. M. Pozar, Microwave Engineering, 3rd ed., John Wiley & Sons, Inc., ISBN: 0-471-32282-2, 2005.
    • (2005) Microwave Engineering
    • Pozar, D.M.1
  • 12
    • 34250198310 scopus 로고    scopus 로고
    • Partial discharge diagnosis method using electromagnetic wave mode transformation in gas insulated switchgear
    • S. Okabe, S. Kaneko, M. Yoshimura, H. Muto, C. Nishida and M. Kamei, "Partial Discharge Diagnosis Method Using Electromagnetic Wave Mode Transformation in Gas Insulated Switchgear", IEEE Trans. Dielectr. Electr. Insul., Vol.14, pp. 702-709, 2007.
    • (2007) IEEE Trans. Dielectr. Electr. Insul. , vol.14 , pp. 702-709
    • Okabe, S.1    Kaneko, S.2    Yoshimura, M.3    Muto, H.4    Nishida, C.5    Kamei, M.6
  • 13
    • 54949136481 scopus 로고    scopus 로고
    • Partial discharge diagnosis method using electromagnetic wave mode transformation in actual gis structure
    • S. Kaneko, S. Okabe, M. Yoshimura, H. Muto, C. Nishida and M. Kamei, "Partial Discharge Diagnosis Method Using Electromagnetic Wave Mode Transformation in Actual GIS Structure", IEEE Trans. Dielectr. Electr. Insul.,Vol. 15, pp. 1329-1339, 2008.
    • (2008) IEEE Trans. Dielectr. Electr. Insul. , vol.15 , pp. 1329-1339
    • Kaneko, S.1    Okabe, S.2    Yoshimura, M.3    Muto, H.4    Nishida, C.5    Kamei, M.6
  • 14
    • 61349119453 scopus 로고    scopus 로고
    • Electromagnetic wave radiated from an insulation spacer in gas insulated switchgear with partial discharge detection
    • S. Kaneko, S. Okabe, H. Muto, M. Yoshimura, C. Nishida and M. Kamei, "Electromagnetic Wave Radiated from an Insulation Spacer in Gas Insulated Switchgear with Partial Discharge Detection", IEEE Trans. Dielectr. Electr. Insul., Vol.16, pp. 60-68, 2009.
    • (2009) IEEE Trans. Dielectr. Electr. Insul. , vol.16 , pp. 60-68
    • Kaneko, S.1    Okabe, S.2    Muto, H.3    Yoshimura, M.4    Nishida, C.5    Kamei, M.6