메뉴 건너뛰기




Volumn 31, Issue 4, 2009, Pages 316-325

An evaluation of the antimicrobial effects of gas-phase ozone

Author keywords

Air Treatment; Antimicrobial Efficacy; Building Materials; Germicidal; Ozone; Porous Non Porous Coupons

Indexed keywords

AIR TREATMENT; ANTI-MICROBIAL EFFECTS; ANTIMICROBIAL EFFICACY; BIOCIDAL; GAS PHASE OZONE; GASEOUS OZONE; GERMICIDAL; GLASS SLIDES; GYPSUM WALLBOARDS; HIGH CONCENTRATION; POROUS SURFACE; POROUS/NON-POROUS COUPONS; RELATIVE HUMIDITIES;

EID: 70449371223     PISSN: 01919512     EISSN: 15476545     Source Type: Journal    
DOI: 10.1080/01919510903043772     Document Type: Article
Times cited : (7)

References (15)
  • 2
    • 5544270358 scopus 로고
    • Kinetics and Mechanisms of the Gas- Phase Reactions of Ozone with Organic Compounds under Atmospheric Conditions
    • Atkinson, R., W.P.L. Carter, Kinetics and Mechanisms of the Gas- Phase Reactions of Ozone with Organic Compounds under Atmospheric Conditions, Chemical Review, 84:5:437-469 (1984).
    • (1984) Chemical Review , vol.84 , pp. 437-469
    • Atkinson, R.1    Carter, W.P.L.2
  • 3
    • 0028015695 scopus 로고
    • Development of Ozone Reactivity Scales for Volatile Organic Compounds
    • Carter, W.P.L., Development of Ozone Reactivity Scales for Volatile Organic Compounds. J. Air Waste Manag. Assoc. 44, 881-899 (1994).
    • (1994) J. Air Waste Manag. Assoc , vol.44 , pp. 881-899
    • Carter, W.P.L.1
  • 5
    • 0032766042 scopus 로고    scopus 로고
    • Hydroxyl Radical/Ozone Ratios during Ozonation Processes. I
    • International Ozone Association, USA
    • Elovitz, M. S. von Gunten, 'Hydroxyl Radical/Ozone Ratios during Ozonation Processes. I', The Rct Concept Ozone: Science & Engineering, 21(3):239-260, International Ozone Association, USA (1999).
    • (1999) ct Concept Ozone: Science & Engineering , vol.21 , Issue.3 , pp. 239-260
    • Elovitz, M.S.G.1
  • 6
    • 0030863563 scopus 로고    scopus 로고
    • Investigation of Gas-Phase Ozone as a Potential Biocide
    • Foarde, K.K., D. VanOsdell and R. Steiber, 'Investigation of Gas-Phase Ozone as a Potential Biocide', Appl. Occup. Environ. Hyg., 12(8):535-542 (1997).
    • (1997) Appl. Occup. Environ. Hyg , vol.12 , Issue.8 , pp. 535-542
    • Foarde, K.K.1    Vanosdell, D.2    Steiber, R.3
  • 7
    • 0009539236 scopus 로고
    • Chemical Food Preservatives
    • Fourth Edition, S.S.Blocked., Lea and Febiger, Publishers. Philadelphia, US Army, Brooke Army Medical Center, World Cat Desc
    • Foegeding, P.M. and F.F. Busta, 'Chemical Food Preservatives', in: Disinfection, Sterilization and Preservation. Fourth Edition, S.S.Blocked., Lea and Febiger, Publishers. Philadelphia, US Army, Brooke Army Medical Center, World Cat Desc:802-832 (1991).
    • (1991) Disinfection, Sterilization and Preservation , pp. 802-832
    • Foegeding, P.M.1    Busta, F.F.2
  • 8
    • 35548930960 scopus 로고
    • Preliminary Investigations On The Reactivity Of Ozone Considering Energy Supplied To Ozone Generators
    • Qadeer, E., Q. Limvorapituk, and J.C. Mora, 'Preliminary Investigations On The Reactivity Of Ozone Considering Energy Supplied To Ozone Generators', Ozone: Science and Engineering, 17(3):267-281 (1995).
    • (1995) Ozone: Science and Engineering , vol.17 , Issue.3 , pp. 267-281
    • Qadeer, E.1    Limvorapituk, Q.2    Mora, J.C.3
  • 9
    • 2442641429 scopus 로고    scopus 로고
    • Full-Scale Chamber Investigation and Simulation of Air Freshener Emissions in the Presence of Ozone
    • Lui, X., A.M. Mason, K. Krebs, and L.E. Sparks, 'Full-Scale Chamber Investigation and Simulation of Air Freshener Emissions in the Presence of Ozone', Environ. Sci. Technol., 38:2802-2812 (2004).
    • (2004) Environ. Sci. Technol , vol.38 , pp. 2802-2812
    • Lui, X.1    Mason, A.M.2    Krebs, K.3    Sparks, L.E.4
  • 11
    • 0006064522 scopus 로고
    • Use of Hazard Communication Standard and General Duty Clause During Remediation of Fungal Contamination
    • Morey, P.R., 'Use of Hazard Communication Standard and General Duty Clause During Remediation of Fungal Contamination', In: Indoor Air'93 Proceedings 4:391-395 (1993).
    • (1993) Indoor Air'93 Proceedings , vol.4 , pp. 391-395
    • Morey, P.R.1
  • 12
    • 8544220428 scopus 로고
    • The Use of Ozone Generators for the Control of Indoor Air Contaminants in an Occupied Environment
    • Shaughnessey, R.J. and L. Oatman, 'The Use of Ozone Generators for the Control of Indoor Air Contaminants in an Occupied Environment', in: IAQ 1991 Proceedings, pp 318-324 (1991).
    • (1991) IAQ 1991 Proceedings, pp , pp. 318-324
    • Shaughnessey, R.J.1    Oatman, L.2
  • 14
    • 0347165939 scopus 로고
    • Disinfection and Sterilization by Ozone
    • S.S. Block, 4th ed. Philadelphia: Les and Febiger Publishers
    • Wickramanayake, G.B., 'Disinfection and Sterilization by Ozone', in: Disinfection, Sterilization, and Preservation. S.S. Block, 4th ed. Philadelphia: Les and Febiger Publishers (1991).
    • (1991) Disinfection, Sterilization, and Preservation
    • Wickramanayake, G.B.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.