메뉴 건너뛰기




Volumn , Issue , 2009, Pages 423-430

Wedjat: A mobile phone based medicine in-take reminder and monitor

Author keywords

Medication error prevention; Mobile computing; Real time scheduling; Telemonitoring

Indexed keywords

DESIGN PRINCIPLES; ERROR PRONES; FOOD INTERACTIONS; HEALTH CARE PROFESSIONALS; MEDICAL ERRORS; MEDICATION ERROR PREVENTION; MEDICATION ERRORS; MOBILE PLATFORM; MODULAR IMPLEMENTATION; ON TIME; POTENTIAL DRUG; PROOF OF CONCEPT; REAL-TIME SCHEDULING; SMART PHONES; SYSTEM CONCEPTS; TELEMONITORING; USER FRIENDLY INTERFACE;

EID: 70449369042     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/BIBE.2009.60     Document Type: Conference Paper
Times cited : (40)

References (17)
  • 3
    • 14544304095 scopus 로고    scopus 로고
    • Role of Computerized Physician Order Entry Systems in Facilitating Medication Errors
    • Koppel B, et al., "Role of Computerized Physician Order Entry Systems in Facilitating Medication Errors," Journal of American Medical Association, Vol. 293, No. 10, 2005.
    • (2005) Journal of American Medical Association , vol.293 , Issue.10
    • Koppel, B.1
  • 8
    • 0037628169 scopus 로고    scopus 로고
    • Automated medication dispensing devices
    • Chapter 11, 01-E58, Agent for Healthcare Research and Quality
    • Murray MD, "Automated medication dispensing devices," Chapter 11 in Making Healthcare Safer: a Critical Analysis of Patient Safety, 01-E58, Agent for Healthcare Research and Quality, 2001.
    • (2001) Making Healthcare Safer: A Critical Analysis of Patient Safety
    • Murray, M.D.1
  • 13
    • 70449421240 scopus 로고    scopus 로고
    • Tsai, P. H., C. S. Shih, and J. W. S. Liu, Algorithms for scheduling multiple interacting medications, Institute of Information Science Academia Sinica, Taiwan, Technical Report TR-IIS-08-001, April 2008.
    • Tsai, P. H., C. S. Shih, and J. W. S. Liu, "Algorithms for scheduling multiple interacting medications," Institute of Information Science Academia Sinica, Taiwan, Technical Report TR-IIS-08-001, April 2008.
  • 14
    • 70449445464 scopus 로고    scopus 로고
    • e-Pill: http://www.epill.com/dispenser.html.
    • e-Pill: http://www.epill.com/dispenser.html.
  • 15
    • 70449415767 scopus 로고    scopus 로고
    • MD2: http://www.epill.com/md2.html.
    • MD2: http
  • 16
    • 70449452777 scopus 로고    scopus 로고
    • Pill boxes: http://www.dynamicliving.com/automated-medication-dispenser. htm.
    • Pill boxes
  • 17
    • 48349128404 scopus 로고    scopus 로고
    • Rx Showcase, http://www.rxinsider.com/prescription-dispensing-automation. htm.
    • Rx Showcase


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.