메뉴 건너뛰기




Volumn 3, Issue , 2009, Pages 254-258

Finite element analysis on the mechanical effect of a roughened stem for cemented hip prosthesis

Author keywords

Cemented prosthesis; Interfacial strength; Roughed stem

Indexed keywords

ANALYSIS MODELS; BONDING STRENGTH; CEMENTED HIP PROSTHESIS; CEMENTED PROSTHESIS; FINITE ELEMENT ANALYSIS; FIXATION STRENGTH; INTERFACIAL BONDING STRENGTH; INTERFACIAL PROPERTY; INTERFACIAL STRENGTH; LOADING PATH; LONG TERM PERFORMANCE; MECHANICAL EFFECTS; MECHANICAL PERFORMANCE; METALLIC PROSTHESIS; ROUGHED STEM; ROUGHENED SURFACES; SHEARING TESTS; STRESS DISTRIBUTION;

EID: 70449132338     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/CSIE.2009.931     Document Type: Conference Paper
Times cited : (2)

References (24)
  • 1
    • 0026594536 scopus 로고
    • The first 32 years of total hip arthroplasty: One surgeon's perspective
    • Harris, W. H., "The first 32 years of total hip arthroplasty: one surgeon's perspective", Clin Orthop, 274, 1992, pp.6-11.
    • (1992) Clin Orthop , vol.274 , pp. 6-11
    • Harris, W.H.1
  • 2
    • 0029112497 scopus 로고
    • Early loosening of the femoral component at the cement-prosthesis: Interface after total hip replacement
    • Mohler, C. G., Callaghan, J, J., Collis, D. K., Johnston, R. C., "Early loosening of the femoral component at the cement-prosthesis: interface after total hip replacement", J Bone Joint Surg, 77A, 1995, pp.1315-1322.
    • (1995) J Bone Joint Surg , vol.77 A , pp. 1315-1322
    • Mohler, C.G.1    Callaghan, J.J.2    Collis, D.K.3    Johnston, R.C.4
  • 3
    • 0026605414 scopus 로고
    • Mechanism and clinical significance of wear debris-induced osteolysis
    • Amstutz, H. C., and Campebell, P., "Mechanism and clinical significance of wear debris-induced osteolysis", Clin Orthop, 276, 1992, pp.7-18.
    • (1992) Clin Orthop , vol.276 , pp. 7-18
    • Amstutz, H.C.1    Campebell, P.2
  • 4
    • 0025147719 scopus 로고
    • Histomorphological studies of the long-term skeltal responses to well fixed cemented femoral components
    • Jasty, M., Maloney, W. J., Bradgon, C. R., Haire, T. and Harris, W. H., "Histomorphological studies of the long-term skeltal responses to well fixed cemented femoral components", J Bone Joint Surg, 72, 1990, pp.1220-1229.
    • (1990) J Bone Joint Surg , vol.72 , pp. 1220-1229
    • Jasty, M.1    Maloney, W.J.2    Bradgon, C.R.3    Haire, T.4    Harris, W.H.5
  • 5
    • 0031052909 scopus 로고    scopus 로고
    • Cement debonding process of total hip arthroplasty stems
    • Verdonschot, N., and Huiskes, R., "Cement debonding process of total hip arthroplasty stems", Clin Orthop, 336,1997, pp.297-307.
    • (1997) Clin Orthop , vol.336 , pp. 297-307
    • Verdonschot, N.1    Huiskes, R.2
  • 6
    • 0024551058 scopus 로고
    • Early femoral component loosening in DF-80 total hip arthroplasty
    • Robinson, R. P., Lovell, T. P., Green, T. M., and Baliey, G. A., "Early femoral component loosening in DF-80 total hip arthroplasty", J Arthroplasty, 4, 1989, pp.55-64.
    • (1989) J Arthroplasty , vol.4 , pp. 55-64
    • Robinson, R.P.1    Lovell, T.P.2    Green, T.M.3    Baliey, G.A.4
  • 8
    • 0028121998 scopus 로고
    • The femoral component in total hip arthroplasty. Six to eight-year follow-up of one hundred consecutive patients after use of a third-generation cementing technique
    • Oishi, C. S., Walker, R. H., and Colwell, C. W., "The femoral component in total hip arthroplasty. Six to eight-year follow-up of one hundred consecutive patients after use of a third-generation cementing technique", J Bone Joint Surg,76, 1994, pp.1130-1136.
    • (1994) J Bone Joint Surg , vol.76 , pp. 1130-1136
    • Oishi, C.S.1    Walker, R.H.2    Colwell, C.W.3
  • 9
    • 0029557806 scopus 로고
    • Total hip arthroplasty with use of so-called second-generation cementing techniques. A fifteen-year-average follow-up study
    • Mulroy, W. F., Estok, D. M., and Harris, W. H., "Total hip arthroplasty with use of so-called second-generation cementing techniques. A fifteen-year-average follow-up study", J Bone Joint Surg, 77, 1995, pp.1845-1852.
    • (1995) J Bone Joint Surg , vol.77 , pp. 1845-1852
    • Mulroy, W.F.1    Estok, D.M.2    Harris, W.H.3
  • 10
    • 0027399214 scopus 로고
    • Penetration and shear strength of cement-bone interfaces in vivo
    • MacDonald, W., Swarts, E., Beaver, R., "Penetration and shear strength of cement-bone interfaces in vivo", Clin Orthop Relat Res, 286, 1993, pp.283-288.
    • (1993) Clin Orthop Relat Res , vol.286 , pp. 283-288
    • MacDonald, W.1    Swarts, E.2    Beaver, R.3
  • 11
    • 0020954642 scopus 로고
    • Effect of pressurization on methylmethacrylate-bone interdigitation: An in vitro study of canine femora
    • Panjabi, M. M., Goel, V.K., Drinker, H., Wong, J., Kamire, G., and Walter, S. D., "Effect of pressurization on methylmethacrylate-bone interdigitation: an in vitro study of canine femora", J Biomech,16(7), 1983, pp.73-480.
    • (1983) J Biomech , vol.16 , Issue.7 , pp. 73-480
    • Panjabi, M.M.1    Goel, V.K.2    Drinker, H.3    Wong, J.4    Kamire, G.5    Walter, S.D.6
  • 12
    • 0027167439 scopus 로고
    • Bone surface preparation in cemented joint replacement
    • Majkowski, R. S., Milles, A. W., and Bannister, G. C., "Bone surface preparation in cemented joint replacement", J Bone Joint Surg, 75B, 1993, pp.459-463
    • (1993) J Bone Joint Surg , vol.75 B , pp. 459-463
    • Majkowski, R.S.1    Milles, A.W.2    Bannister, G.C.3
  • 13
    • 1642385946 scopus 로고    scopus 로고
    • Strengthening mechanisms of bone bonding to crystalline hydroxyapatite in vivo
    • Chen, Q. Z., Wong, C. T., Lu, W. W., Chung, K.M.C., Leong,Y. C., and Luk, K. D. K., "Strengthening mechanisms of bone bonding to crystalline hydroxyapatite in vivo" Biomaterials, 25, 2004, pp.4243-4254.
    • (2004) Biomaterials , vol.25 , pp. 4243-4254
    • Chen, Q.Z.1    Wong, C.T.2    Lu, W.W.3    Chung, K.M.C.4    Leong, Y.C.5    Luk, K.D.K.6
  • 14
    • 0023367463 scopus 로고
    • The effect of surface preparation on metal/bone cement interfacial strength
    • Bundy, K. J., Penn, R. W., "The effect of surface preparation on metal/bone cement interfacial strength", J Biomed Mater Res, 21, 1987, pp.773-805.
    • (1987) J Biomed Mater Res , vol.21 , pp. 773-805
    • Bundy, K.J.1    Penn, R.W.2
  • 15
    • 0032767428 scopus 로고    scopus 로고
    • Effect of metal surface topography on mechanical bonding at simulated total hip stem-cement interfaces
    • Chen, C. Q., Scott, W., Barker, T.M., "Effect of metal surface topography on mechanical bonding at simulated total hip stem-cement interfaces", J. Biomed. Mater Res, 48, 1999, pp.440-446.
    • (1999) J. Biomed. Mater Res , vol.48 , pp. 440-446
    • Chen, C.Q.1    Scott, W.2    Barker, T.M.3
  • 16
    • 0032947562 scopus 로고    scopus 로고
    • The effects of surface roughness and polymethylmethacrylate precoating on the radiographic and clinical results of the Iowa hip prosthesis. A study of patients less than .fifty years old
    • Sporer, S. M., Callaghan, J. J., Olejniczak, J. P., Goetz, D. D., Johnston, R. C., "The effects of surface roughness and polymethylmethacrylate precoating on the radiographic and clinical results of the Iowa hip prosthesis. A study of patients less than .fifty years old", J Bone Joint Surg Am, 81, 1999, pp.481-492.
    • (1999) J Bone Joint Surg Am , vol.81 , pp. 481-492
    • Sporer, S.M.1    Callaghan, J.J.2    Olejniczak, J.P.3    Goetz, D.D.4    Johnston, R.C.5
  • 17
    • 0028058237 scopus 로고
    • Failure of the cement-bone interface. A consequence of strengthening the cement-prosthesis interface?
    • Gardiner, R. C., Hozack, W. J., "Failure of the cement-bone interface. A consequence of strengthening the cement-prosthesis interface?", J Bone Joint Surg, 76 (B), 1994, pp.49-52.
    • (1994) J Bone Joint Surg , vol.76 , Issue.B , pp. 49-52
    • Gardiner, R.C.1    Hozack, W.J.2
  • 18
    • 0031828375 scopus 로고    scopus 로고
    • Loosening of matt and polished cemented femoral stems
    • Howie, D. W., Middleton, R. G., Costi, K., "Loosening of matt and polished cemented femoral stems",J Bone Joint Surg, 80(B), 1998, pp.573-576.
    • (1998) J Bone Joint Surg , vol.80 , Issue.B , pp. 573-576
    • Howie, D.W.1    Middleton, R.G.2    Costi, K.3
  • 19
    • 0029112497 scopus 로고
    • Early loosening of the femoral component at the cement-prosthesis interface after total hip replacement
    • Mohler, C. G., Callaghan, J. J., Collis, D. K., Johnston, R. C., "Early loosening of the femoral component at the cement-prosthesis interface after total hip replacement", J Bone Joint Surg, 77(A), 1995, pp.1315-1322.
    • (1995) J Bone Joint Surg , vol.77 , Issue.A , pp. 1315-1322
    • Mohler, C.G.1    Callaghan, J.J.2    Collis, D.K.3    Johnston, R.C.4
  • 20
    • 0031762032 scopus 로고    scopus 로고
    • Effect of design changes on cemented tapered femoral stem fixation
    • Middleton, R. G., Howie, D. W., Costi, K., Sharpe, P., "Effect of design changes on cemented tapered femoral stem fixation", Clin. Orthop, 355, 1998, pp.47-56.
    • (1998) Clin. Orthop , vol.355 , pp. 47-56
    • Middleton, R.G.1    Howie, D.W.2    Costi, K.3    Sharpe, P.4
  • 21
    • 21844474079 scopus 로고    scopus 로고
    • A rough surface finish adversely affect the survivorship of a cemented femoral stem
    • Valle, A. G., Zoppi, A., Peterson, M. G. E., Salvati, E. A., "A rough surface finish adversely affect the survivorship of a cemented femoral stem", Clin. Orthop. Relat. Res, 436, 2005, pp.158-163.
    • (2005) Clin. Orthop. Relat. Res , vol.436 , pp. 158-163
    • Valle, A.G.1    Zoppi, A.2    Peterson, M.G.E.3    Salvati, E.A.4
  • 22
    • 0344097815 scopus 로고
    • Ph.D. Dissertation, University of Glasgow, Glasgow, Scotland
    • Paul, J.P., Force at the Human Hip Joint, Ph.D. Dissertation, University of Glasgow, Glasgow, Scotland, 1967.
    • (1967) Force at the Human Hip Joint
    • Paul, J.P.1
  • 24
    • 0032767428 scopus 로고    scopus 로고
    • Effect of metal surface topography on mechanical bonding at simulated total hip stem-cement interfaces
    • Christina, Q. L., Chen, W. S., Timothy, M, B., "Effect of metal surface topography on mechanical bonding at simulated total hip stem-cement interfaces", J. Biomed. Mater. Res. (Applied Biomaterials) 48(4), 1999, pp.440-446.
    • (1999) J. Biomed. Mater. Res. (Applied Biomaterials) , vol.48 , Issue.4 , pp. 440-446
    • Christina, Q.L.1    Chen, W.S.2    Timothy, M.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.