Online solid phase preconcentration using EGDMA-MAA copolymer for lead determination by FAAS

Author keywords

Flow injection; Lead; Preconcentration; Solid phase extraction

Indexed keywords

BUFFALO RIVER; CERTIFIED REFERENCE MATERIALS; DETECTION LIMITS; ELUENT TYPE; ENRICHMENT FACTORS; ETHYLENE GLYCOL DIMETHACRYLATE; FLAME ATOMIC ABSORPTION SPECTROMETRY; FLOW-INJECTION; LEAD DETERMINATION; LEAD IONS; METHACRYLIC ACIDS; NITRIC ACID SOLUTIONS; OPTIMUM CONDITIONS; PRECONCENTRATION; RIVER WATER SAMPLES; SAMPLE VOLUME; SOLID PHASE EXTRACTION; SOLID PHASE EXTRACTION METHOD; SOLID-PHASE; TRACE LEVEL; WATER SAMPLES;

EID: 70350764789     PISSN: 02772248     EISSN: 10290486     Source Type: Journal    
DOI: 10.1080/02772240802631899     Document Type: Article
Times cited : (3)

References (41)
  • 2
    • 33746210088 scopus 로고    scopus 로고
    • Evaluation of polychlorotrifluoroethylene as sorbent material for on-line solid phase extraction systems: Determination of copper and lead by flame atomic absorption spectrometry in water samples
    • Anthemidis, A.N., and K.I.G. Ioannou. 2006. Evaluation of polychlorotrifluoroethylene as sorbent material for on-line solid phase extraction systems: Determination of copper and lead by flame atomic absorption spectrometry in water samples. Analytica Chimica Acta 575: 126-32.
    • (2006) Analytica Chimica Acta , vol.575 , pp. 126-32
    • Anthemidis, A.N.1    Ioannou, K.I.G.2
  • 3
    • 23044476090 scopus 로고    scopus 로고
    • A novel preconcentration method for determination of iron and lead using Chromosorb-103 and flame atomic absorption spectrometry
    • Bakircioglu, Y., D. Bakircioglu, and N. Tokman. 2005. A novel preconcentration method for determination of iron and lead using Chromosorb-103 and flame atomic absorption spectrometry. Analytica Chimica Acta 457: 26-30.
    • (2005) Analytica Chimica Acta , vol.457 , pp. 26-30
    • Bakircioglu, Y.1    Bakircioglu, D.2    Tokman, N.3
  • 4
    • 0038663124 scopus 로고    scopus 로고
    • ® for flow-injection solid-phase extraction preconcentration for the determination of trace lead in water and wine by flame atomic absorption spectrometry
    • ® for flow-injection solid-phase extraction preconcentration for the determination of trace lead in water and wine by flame atomic absorption spectrometry. Analytica Chimica Acta 485: 9-18.
    • (2003) Analytica Chimica Acta , vol.485 , pp. 9-18
    • Bakircioglu, Y.1    Segade, S.R.2    Yourd, E.R.3    Tyson, J.F.4
  • 5
    • 33847106365 scopus 로고    scopus 로고
    • Solid-phase extraction system for Pb (II) ions using enrichment based on multiwall carbon nanotubes coupled on-line to flame atomic absorption spectrometry
    • Barbosa, A.F., M.G. Segatelli, A.C. Pereira, A.D. Santos, L.T. Kubota, P.O. Luccas, and C.R.T. Tarley. 2007. Solid-phase extraction system for Pb (II) ions using enrichment based on multiwall carbon nanotubes coupled on-line to flame atomic absorption spectrometry. Talanta 71: 1512-9.
    • (2007) Talanta , vol.71 , pp. 1512-9
    • Barbosa, A.F.1    Segatelli, M.G.2    Pereira, A.C.3    Santos, A.D.4    Kubota, L.T.5    Luccas, P.O.6    Tarley, C.R.T.7
  • 6
    • 0037774189 scopus 로고    scopus 로고
    • Crosslinked poly(styrenesulfonamide) with iminoacetic acid chelating groups for hard-water treatment
    • Bicak, N., B.F. Senkal, and T. Yarbas. 1998. Crosslinked poly(styrenesulfonamide) with iminoacetic acid chelating groups for hard-water treatment. Macromolecular Chemistry and Physics 199: 2731-5.
    • (1998) Macromolecular Chemistry and Physics , vol.199 , pp. 2731-5
    • Bicak, N.1    Senkal, B.F.2    Yarbas, T.3
  • 7
    • 0038784768 scopus 로고    scopus 로고
    • Solid phase extraction of trace elements
    • Camel, V. 2003. Solid phase extraction of trace elements. Spectrochimica Acta, Part B 58: 1117-233.
    • Spectrochimica Acta Part B , vol.58 , pp. 1117-233
    • Camel, V.1
  • 8
    • 0342955735 scopus 로고    scopus 로고
    • Flow injection solid phase extraction with Chromosorb- 102: Determination of lead in soil and waters by flame atomic absorption spectrometry
    • Elci, L., Z. Arslan, and J.F. Tyson. 2000. Flow injection solid phase extraction with Chromosorb- 102: Determination of lead in soil and waters by flame atomic absorption spectrometry.Spectrochimica Acta, Part B 55: 1109-16.
    • (2000) Spectrochimica Acta, Part B , vol.55 , pp. 1109-16
    • Elci, L.1    Arslan, Z.2    Tyson, J.F.3
  • 11
    • 0346965665 scopus 로고    scopus 로고
    • Selective preconcentration of ultra trace copper(II) using octadecyl silica membrane disks modified by a recently synthesized glyoxime derivative
    • Ghiasvand, A.R., R. Ghaderi, and A. Kakanejadifard. 2004. Selective preconcentration of ultra trace copper(II) using octadecyl silica membrane disks modified by a recently synthesized glyoxime derivative. Talanta 62: 287-92.
    • (2004) Talanta , vol.62 , pp. 287-92
    • Ghiasvand, A.R.1    Ghaderi, R.2    Kakanejadifard, A.3
  • 12
    • 0346059612 scopus 로고    scopus 로고
    • ICP-OES determination of cobalt in natural water using a flow injection system after preconcentration on activated carbon
    • Gil, R.A., S. Cerutti, J.A. Gasquez, R.A. Olsina, and L.D. Martinez. 2003. ICP-OES determination of cobalt in natural water using a flow injection system after preconcentration on activated carbon. Atomic Spectroscopy 24: 213-7.
    • (2003) Atomic Spectroscopy , vol.24 , pp. 213-7
    • Gil, R.A.1    Cerutti, S.2    Gasquez, J.A.3    Olsina, R.A.4    Martinez, L.D.5
  • 13
    • 0041925222 scopus 로고    scopus 로고
    • 8-Hydroxyquinoline anchored to silica gel via new moderate size linker: Synthesis and applications as a metal ion collector for their flame atomic absorption spectrometric determination
    • Goswami, A., A.K. Singh, and B. Venkataramani. 2003. 8-Hydroxyquinoline anchored to silica gel via new moderate size linker: Synthesis and applications as a metal ion collector for their flame atomic absorption spectrometric determination. Talanta 60: 1141-54.
    • (2003) Talanta , vol.60 , pp. 1141-54
    • Goswami, A.1    Singh, A.K.2    Venkataramani, B.3
  • 14
    • 33644825722 scopus 로고    scopus 로고
    • Synthesis of hydrophilic macroporous chelating polymers and their versatility in the preconcentration of metals in seawater samples
    • Haratake, M., K. Yasumoto, M. Ono, M. Akashi, and M. Nakayama. 2006. Synthesis of hydrophilic macroporous chelating polymers and their versatility in the preconcentration of metals in seawater samples. Analytica Chimica Acta 561: 183-90.
    • (2006) Analytica Chimica Acta , vol.561 , pp. 183-90
    • Haratake, M.1    Yasumoto, K.2    Ono, M.3    Akashi, M.4    Nakayama, M.5
  • 15
    • 43949150511 scopus 로고
    • Preparation of Amberlite XAD resins coated with dithiosemicarbazone compounds and preconcentration of some metal-ions
    • Hoshi, S., H. Fujisawa, K. Nakamura, S. Nakata, M. Uto, and K. Akatsuka. 1994. Preparation of Amberlite XAD resins coated with dithiosemicarbazone compounds and preconcentration of some metal-ions. Talanta 41: 503-7.
    • (1994) Talanta , vol.41 , pp. 503-7
    • Hoshi, S.1    Fujisawa, H.2    Nakamura, K.3    Nakata, S.4    Uto, M.5    Akatsuka, K.6
  • 16
    • 1542719131 scopus 로고    scopus 로고
    • On-line preconcentration and simultaneous determination of heavy metal ions by inductively coupled plasma-atomic emission spectrometry
    • Karami, H., M.F. Mousavi, Y. Yamini, and M. Shamsipur. 2004. On-line preconcentration and simultaneous determination of heavy metal ions by inductively coupled plasma-atomic emission spectrometry. Analytica Chimica Acta 509: 89-94.
    • (2004) Analytica Chimica Acta , vol.509 , pp. 89-94
    • Karami, H.1    Mousavi, M.F.2    Yamini, Y.3    Shamsipur, M.4
  • 17
    • 0036643243 scopus 로고    scopus 로고
    • Removal of heavy metal ions from water by using poly(ethyleneglycol dimethacrylate-co-acrylamide) beads
    • Kesenci, K., R. Say, and A. Denizli. 2002. Removal of heavy metal ions from water by using poly(ethyleneglycol dimethacrylate-co-acrylamide) beads. The European Polymer Journal 38: 1443-8.
    • (2002) The European Polymer Journal , vol.38 , pp. 1443-8
    • Kesenci, K.1    Say, R.2    Denizli, A.3
  • 19
    • 0034608098 scopus 로고    scopus 로고
    • Amberlite XAD-2 functionalized with o-aminophenol: Synthesis and applications as extractant for copper(II), cobalt(II), cadmium(II), nickel(lI), zinc(II) and lead(II)
    • Kumar, M.M., D.P.S. Rathore, and A.K. Singh. 2000. Amberlite XAD-2 functionalized with o-aminophenol: Synthesis and applications as extractant for copper(II), cobalt(II), cadmium(II), nickel(lI), zinc(II) and lead(II). Talanta 51: 1187-96.
    • (2000) Talanta , vol.51 , pp. 1187-96
    • Kumar, M.M.1    Rathore, D.P.S.2    Singh, A.K.3
  • 20
    • 0035943527 scopus 로고    scopus 로고
    • On-line preconcentration systems for lead determination in seafood samples by flame atomic absorption spectrometry using polyurethane foam loaded with 2-(2-benzothiazolylazo)-2-p-cresol
    • Lemos, V.A., and S.L.C. Ferreira. 2001. On-line preconcentration systems for lead determination in seafood samples by flame atomic absorption spectrometry using polyurethane foam loaded with 2-(2-benzothiazolylazo)-2-p-cresol. Analytica Chimica Acta 441: 281-9.
    • (2001) Analytica Chimica Acta , vol.441 , pp. 281-9
    • Lemos, V.A.1    Ferreira, S.L.C.2
  • 22
    • 0034609463 scopus 로고    scopus 로고
    • Determination of trace metal ions by AAS in natural water samples after preconcentration of pyrocatechol violet complexes on an activated carbon column
    • Narin, I., M. Soylak, and M. Dogan. 2000. Determination of trace metal ions by AAS in natural water samples after preconcentration of pyrocatechol violet complexes on an activated carbon column. Talanta 52: 1041-6.
    • (2000) Talanta , vol.52 , pp. 1041-6
    • Narin, I.1    Soylak, M.2    Dogan, M.3
  • 23
    • 0020968313 scopus 로고
    • Combination of flow injection analysis with flame atomic absorption spectrometry determination of trace amounts of heavy metals in polluted seawater
    • Olsen, S., L.C.R. Pessenda, J. Ruzicka, and E.H. Hansen. 1983. Combination of flow injection analysis with flame atomic absorption spectrometry determination of trace amounts of heavy metals in polluted seawater. Analyst 108: 905-17.
    • (1983) Analyst , vol.108 , pp. 905-17
    • Olsen, S.1    Pessenda, L.C.R.2    Ruzicka, J.3    Hansen, E.H.4
  • 24
    • 0036308165 scopus 로고    scopus 로고
    • The use of water soluble polymers for the pre-concentration and separation of copper, lead and chromium prior to their determination by graphite furnace atomic absorption spectrometry
    • Ozcan, M., S. Akman, and C. Ozeroglu. 2002. The use of water soluble polymers for the pre-concentration and separation of copper, lead and chromium prior to their determination by graphite furnace atomic absorption spectrometry. Analytical Letters 35: 1075-83.
    • (2002) Analytical Letters , vol.35 , pp. 1075-83
    • Ozcan, M.1    Akman, S.2    Ozeroglu, C.3
  • 25
    • 34547873139 scopus 로고    scopus 로고
    • Kinetics of the adsorption of strontium ions by a crosslinked copolymer containing methacrylic acid functional groups
    • Ozeroglu, C., and G. Keceli. 2007. Kinetics of the adsorption of strontium ions by a crosslinked copolymer containing methacrylic acid functional groups. Radiochimica Acta 95: 459-66.
    • (2007) Radiochimica Acta , vol.95 , pp. 459-66
    • Ozeroglu, C.1    Keceli, G.2
  • 26
    • 0038640249 scopus 로고    scopus 로고
    • Preconcentration of lead complexed with o,o-diethyl-dithiophosphate by column solid-phase extraction using different sorbents in a flow injection system coupled to a flame atomic absorption spectrometer
    • Quinaia, S.P., J.B.B. Da Silva, M.D.E. Rollemberg, and A.J. Curtius. 2001. Preconcentration of lead complexed with o,o-diethyl-dithiophosphate by column solid-phase extraction using different sorbents in a flow injection system coupled to a flame atomic absorption spectrometer. Talanta 54: 687-96.
    • (2001) Talanta , vol.54 , pp. 687-96
    • Quinaia, S.P.1    da Silva, J.B.B.2    Rollemberg, M.D.E.3    Curtius, A.J.4
  • 27
    • 0030967212 scopus 로고    scopus 로고
    • Pyrocatechol Violet immobilized Amberlite XAD-2: Synthesis and metal-ion uptake properties suitable for analytical applications
    • Saxena, R., and A.K. Singh. 1997. Pyrocatechol Violet immobilized Amberlite XAD-2: Synthesis and metal-ion uptake properties suitable for analytical applications. Analytica Chimica Acta 340: 285-90.
    • (1997) Analytica Chimica Acta , vol.340 , pp. 285-90
    • Saxena, R.1    Singh, A.K.2
  • 28
    • 3543019698 scopus 로고    scopus 로고
    • Silica gel coated with Schiff's base: Synthesis and application as an adsorbent for cadmium, copper, zinc, and nickel determination after preconcentration by flame atomic absorption spectrometry
    • Shemirani, F., A.A. Mirroshandel, M. Salavati-Niasari, and R.R. Kozani. 2004. Silica gel coated with Schiff's base: Synthesis and application as an adsorbent for cadmium, copper, zinc, and nickel determination after preconcentration by flame atomic absorption spectrometry. Journal of Analytical Chemistry 59: 228-33.
    • (2004) Journal of Analytical Chemistry , vol.59 , pp. 228-33
    • Shemirani, F.1    Mirroshandel, A.A.2    Salavati-Niasari, M.3    Kozani, R.R.4
  • 30
    • 0034534859 scopus 로고    scopus 로고
    • Thiosalicylic acid-immobilized Amberlite XAD-2: Metal sorption behavior and applications in estimation of metal ions by flame atomic absorption spectrometry
    • Tewari, P.K., and A.K. Singh. 2000. Thiosalicylic acid-immobilized Amberlite XAD-2: Metal sorption behavior and applications in estimation of metal ions by flame atomic absorption spectrometry. Analyst 125: 2350-5.
    • (2000) Analyst , vol.125 , pp. 2350-5
    • Tewari, P.K.1    Singh, A.K.2
  • 31
    • 0035808439 scopus 로고    scopus 로고
    • Synthesis, characterization and applications of pyrocatechol modified amberlite XAD-2 resin for preconcentration and determination of metal ions in water samples by flame atomic absorption spectrometry (FAAS)
    • Tewari, P.K., and A.K. Singh. 2001. Synthesis, characterization and applications of pyrocatechol modified amberlite XAD-2 resin for preconcentration and determination of metal ions in water samples by flame atomic absorption spectrometry (FAAS). Talanta 53: 823-33.
    • (2001) Talanta , vol.53 , pp. 823-33
    • Tewari, P.K.1    Singh, A.K.2
  • 32
    • 0037061059 scopus 로고    scopus 로고
    • Preconcentration of lead with Amberlite XAD-2 and Amberlite XAD-7 based chelating resins for its determination by FAAS
    • Tewari, P.K., and A.K. Singh. 2002. Preconcentration of lead with Amberlite XAD-2 and Amberlite XAD-7 based chelating resins for its determination by FAAS. Talanta 56: 735-44.
    • (2002) Talanta , vol.56 , pp. 735-44
    • Tewari, P.K.1    Singh, A.K.2
  • 33
    • 2442560261 scopus 로고    scopus 로고
    • Determination of lead, copper and manganese by graphite furnace atomic absorption spectrometry after separation/concentration using a water- soluble polymer
    • Tokman, N., S. Akman, and C. Ozeroglu. 2004. Determination of lead, copper and manganese by graphite furnace atomic absorption spectrometry after separation/concentration using a water- soluble polymer. Talanta 63: 699-703.
    • (2004) Talanta , vol.63 , pp. 699-703
    • Tokman, N.1    Akman, S.2    Ozeroglu, C.3
  • 34
    • 0011813399 scopus 로고    scopus 로고
    • The determination of arsenic and selenium in standard reference materials using sector field ICP-MS in high resolution mode
    • Townsend, A.T. 1999. The determination of arsenic and selenium in standard reference materials using sector field ICP-MS in high resolution mode. Fresenius Journal of Analytical Chemistry 364: 521-6.
    • (1999) Fresenius Journal of Analytical Chemistry , vol.364 , pp. 521-6
    • Townsend, A.T.1
  • 35
    • 0025075937 scopus 로고
    • Atomic spectrometric detectors for flow-injection analysis
    • Tyson, J.F. 1990. Atomic spectrometric detectors for flow-injection analysis. Analytica Chimica Acta 234: 3-12.
    • (1990) Analytica Chimica Acta , vol.234 , pp. 3-12
    • Tyson, J.F.1
  • 36
    • 0033075763 scopus 로고    scopus 로고
    • High-performance, flow-based, sample pre-treatment and introduction procedures for analytical atomic spectrometry
    • Tyson, J.F. 1999. High-performance, flow-based, sample pre-treatment and introduction procedures for analytical atomic spectrometry. Journal of Analytical Atomic Spectrometry 14: 169-78.
    • (1999) Journal of Analytical Atomic Spectrometry , vol.14 , pp. 169-78
    • Tyson, J.F.1
  • 37
    • 0034682370 scopus 로고    scopus 로고
    • Visual determination of lead (II) by inhibition of alkaline phosphates immobilized on polyurethane foam
    • Veselova, I.A., and T.N. Shekhovtsova. 2000. Visual determination of lead (II) by inhibition of alkaline phosphates immobilized on polyurethane foam. Analytica Chimica Acta 413: 95-101.
    • (2000) Analytica Chimica Acta , vol.413 , pp. 95-101
    • Veselova, I.A.1    Shekhovtsova, T.N.2
  • 39
    • 0033214668 scopus 로고    scopus 로고
    • Application of a macrocycle immobilized silica gel sorbent to flow injection on-line microcolumn preconcentration and separation coupled with flame atomic absorption spectrometry for interference-free determination of trace lead in biological and environmental samples
    • Yan, X.P., M. Sperling, and B. Welz. 1999. Application of a macrocycle immobilized silica gel sorbent to flow injection on-line microcolumn preconcentration and separation coupled with flame atomic absorption spectrometry for interference-free determination of trace lead in biological and environmental samples. Analytical Chemistry 71: 4216-22.
    • (1999) Analytical Chemistry , vol.71 , pp. 4216-22
    • Yan, X.P.1    Sperling, M.2    Welz, B.3
  • 40
    • 0037014591 scopus 로고    scopus 로고
    • Determination of lead by on-line solid phase extraction using PTFE micro-column and flame atomic absorption spectrometry
    • Zachariadis, G.A., A.N. Anthemidis, P.G. Bettas, and J.A. Stratis. 2002. Determination of lead by on-line solid phase extraction using PTFE micro-column and flame atomic absorption spectrometry. Talanta 57: 919-27.
    • (2002) Talanta , vol.57 , pp. 919-27
    • Zachariadis, G.A.1    Anthemidis, A.N.2    Bettas, P.G.3    Stratis, J.A.4
  • 41
    • 0023705018 scopus 로고
    • On-line preconcentration and determination of lead in potable water by flow injection atomic absorption spectrometry
    • Zhang, Y., P. Riby, A.G. Cox, C.W. McLeod, A.R. Date, and Y.Y. Cheung. 1988. On-line preconcentration and determination of lead in potable water by flow injection atomic absorption spectrometry. Analyst 113: 125-8.
    • (1988) Analyst , vol.113 , pp. 125-8
    • Zhang, Y.1    Riby, P.2    Cox, A.G.3    McLeod, C.W.4    Date, A.R.5    Cheung, Y.Y.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.