메뉴 건너뛰기




Volumn 23, Issue 10, 2009, Pages 702-709

A single-channel telemetric intramedullary nail for in vivo measurement of fracture healing

Author keywords

Femur; Fracture healing; Implant strain; Intramedullary nail; Load share; Monitoring

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL MODEL; ANIMAL TISSUE; ARTICLE; BIOMECHANICS; BONE SCREW; CALLUS; CONTROLLED STUDY; EX VIVO STUDY; FEMALE; FEMUR OSTEOTOMY; FORCE; FRACTURE HEALING; GAIT; IN VIVO STUDY; INTRAMEDULLARY NAIL; LIGAMENT; MICRO-COMPUTED TOMOGRAPHY; MORPHOMETRICS; NONHUMAN; PILOT STUDY; POSTHUMOUS CARE; POSTOPERATIVE PERIOD; PRIORITY JOURNAL; SHEEP; SIGMOID; SOFT TISSUE; STRAIN GAUGE TRANSDUCER; TELEMETRY; X RAY;

EID: 70350749529     PISSN: 08905339     EISSN: None     Source Type: Journal    
DOI: 10.1097/BOT.0b013e3181b01c49     Document Type: Article
Times cited : (17)

References (24)
  • 1
    • 3042793370 scopus 로고    scopus 로고
    • Current intramedullary nail insertion and removal practice in the UK
    • Zenios M. Malik MHA, Al-Mesri AR, et al. Current intramedullary nail insertion and removal practice in the UK. Eur J Orthop Surg Traumatol. 2004;14:19-22.
    • (2004) Eur J Orthop Surg Traumatol , vol.14 , pp. 19-22
    • Zenios, M.1    Malik, M.H.A.2    Al-Mesri, A.R.3
  • 2
    • 0034988889 scopus 로고    scopus 로고
    • Loads acting in an intramedullary nail during fracture healing in the human femur
    • Schneider E, Michel MC, Genge M, et al. Loads acting in an intramedullary nail during fracture healing in the human femur. J Biomech. 2001;34:849-857.
    • (2001) J Biomech , vol.34 , pp. 849-857
    • Schneider, E.1    Michel, M.C.2    Genge, M.3
  • 3
    • 0019120560 scopus 로고
    • Impacted fixation over resilient multiple pins
    • Deverle WM. Impacted fixation over resilient multiple pins. Clin Orthop Relat Res. 1980;152:102-122.
    • (1980) Clin Orthop Relat Res , vol.152 , pp. 102-122
    • Deverle, W.M.1
  • 4
    • 0034397885 scopus 로고    scopus 로고
    • Monitoring in vivo implant loads with a telemeterized internal spinal fixation device
    • Rohlmann A, Graichen F, Bergmann G. Monitoring in vivo implant loads with a telemeterized internal spinal fixation device. Spine. 2000;25:2981-2986.
    • (2000) Spine , vol.25 , pp. 2981-2986
    • Rohlmann, A.1    Graichen, F.2    Bergmann, G.3
  • 5
    • 0036504840 scopus 로고    scopus 로고
    • An implantable strain measurement system designed to detect spine fusion: Preliminary results from a biomechanical in vivo study
    • Szivek JA, Roberto RF, Slack JM, et al. An implantable strain measurement system designed to detect spine fusion: preliminary results from a biomechanical in vivo study. Spine. 2002;27:487-497.
    • (2002) Spine , vol.27 , pp. 487-497
    • Szivek, J.A.1    Roberto, R.F.2    Slack, J.M.3
  • 6
    • 18544408495 scopus 로고    scopus 로고
    • Strain gauges used in the mechanical testing of bones. Part II. in vitro and in vivo techniques
    • Cordey J, Gautier E. Strain gauges used in the mechanical testing of bones. Part II: In vitro and in vivo techniques. Injury. 1999;30: A14-A20.
    • (1999) Injury , vol.30
    • Cordey, J.1    Gautier, E.2
  • 7
    • 0018769760 scopus 로고
    • Blumlein H, Importance of the friction between plate and bone in the anchoring of plates for osteosynthesis. Determination of the coefficient of metal-bone friction in animal in vivo
    • Cordey J, Mikuschka-Galgoczy E, et al. Blumlein H, Importance of the friction between plate and bone in the anchoring of plates for osteosynthesis. Determination of the coefficient of metal-bone friction in animal in vivo. Helv Chir Acta. 1979;46:183-187.
    • (1979) Helv Chir Acta , vol.46 , pp. 183-187
    • Cordey, J.1    Mikuschka-Galgoczy, E.2
  • 8
    • 0034267112 scopus 로고    scopus 로고
    • Strain distribution in plated and unplated sheep tibia an in vivo experiment
    • Gautier E, Perren SM, Cordey J. Strain distribution in plated and unplated sheep tibia an in vivo experiment. Injury. 2000;31:C37-C44.
    • (2000) Injury , vol.31
    • Gautier, E.1    Perren, S.M.2    Cordey, J.3
  • 9
    • 0023500811 scopus 로고
    • Measurement of bending and torsion with and without an intramedullary nail implanted in sheep tibia in vivo
    • Sumner-Smith G, Cordey J, Perren SM. Measurement of bending and torsion with and without an intramedullary nail implanted in sheep tibia in vivo. Arch Orthop Trauma Surg. 1988;107:16-19.
    • (1988) Arch Orthop Trauma Surg , vol.107 , pp. 16-19
    • Sumner-Smith, G.1    Cordey, J.2    Perren, S.M.3
  • 10
    • 0019415986 scopus 로고
    • In vivo strain measurements from bone and prosthesis following total hip replacement. An experimental study in sheep
    • Lanyon LE, Paul IL, Rubin CT, et al. In vivo strain measurements from bone and prosthesis following total hip replacement. An experimental study in sheep. J Bone Joint Surg Am. 1981;63: 989-1001.
    • (1981) J Bone Joint Surg Am , vol.63 , pp. 989-1001
    • Lanyon, L.E.1    Paul, I.L.2    Rubin, C.T.3
  • 11
    • 10644249303 scopus 로고    scopus 로고
    • Functional load of plates in fracture fixation in vivo and its correlate in bone healing
    • Stoffel K, Klaue K, Perren SM. Functional load of plates in fracture fixation in vivo and its correlate in bone healing. Injury Int J Care Injured. 2000;31S-B37-S-B50.
    • (2000) Injury Int J Care Injured , vol.31
    • Stoffel, K.1    Klaue, K.2    Perren, S.M.3
  • 12
    • 70350763546 scopus 로고
    • Of men and sheep-comparison of their hip joint forces
    • Bergmann G, Siraky J, Rohlmann A, et al. Of men and sheep-comparison of their hip joint forces. J Biomech. 1982;15:800.
    • (1982) J Biomech , vol.15 , pp. 800
    • Bergmann, G.1    Siraky, J.2    Rohlmann, A.3
  • 13
    • 0021687842 scopus 로고
    • A comparison of hip forces in sheep, dog and man
    • Bergmann G, Siraky J, Rohlmann A, et al. A comparison of hip forces in sheep, dog and man. J Biomech. 1984;17:907-921.
    • (1984) J Biomech , vol.17 , pp. 907-921
    • Bergmann, G.1    Siraky, J.2    Rohlmann, A.3
  • 16
    • 0018747364 scopus 로고
    • A biomechanical study on the fracture treatment in travital measurement of the strain on an intramedullary nail in the healing process of the femoral fracture in goats
    • Obara T. A biomechanical study on the fracture treatment in travital measurement of the strain on an intramedullary nail in the healing process of the femoral fracture in goats. Nippon Seikeigeka Gakkai zasshi. 1979; 53:199-212.
    • (1979) Nippon Seikeigeka Gakkai Zasshi , vol.53 , pp. 199-212
    • Obara, T.1
  • 18
    • 0031791387 scopus 로고    scopus 로고
    • Effects of mechanical factors on the fracture healing process
    • Claes LE, Heigele CA, Neidlinger-Wilke C, et al. Effects of mechanical factors on the fracture healing process. Clin Orthop Relat Res. 1998; 355(Suppl):S132-S147.
    • (1998) Clin Orthop Relat Res , vol.355 , Issue.SUPPL.
    • Claes, L.E.1    Heigele, C.A.2    Neidlinger-Wilke, C.3
  • 19
    • 32644442726 scopus 로고    scopus 로고
    • Tibio-femoral joint contact forces in sheep
    • Taylor WR, Ehrig RM, Duda GR, et al. Tibio-femoral joint contact forces in sheep. J Biomech. 2006;39:791-798.
    • (2006) J Biomech , vol.39 , pp. 791-798
    • Taylor, W.R.1    Ehrig, R.M.2    Duda, G.R.3
  • 20
    • 32644442726 scopus 로고    scopus 로고
    • Tibio-femoral joint contact forces in sheep
    • Taylor W, Ehrig R, Heller M, et al. Tibio-femoral joint contact forces in sheep. J Biomech. 2007:39:791-798.
    • (2007) J Biomech , vol.39 , pp. 791-798
    • Taylor, W.1    Ehrig, R.2    Heller, M.3
  • 21
    • 0027568465 scopus 로고
    • Loads on muscles, tendons and bones in the hind extremities of sheep-a theoretical study
    • Hutzscenreue PO, Sekler E, Faust G. Loads on muscles, tendons and bones in the hind extremities of sheep-a theoretical study. Anat Histol Embryol. 1993;22:67-82.
    • (1993) Anat Histol Embryol , vol.22 , pp. 67-82
    • Hutzscenreue, P.O.1    Sekler, E.2    Faust, G.3
  • 22
    • 0017103012 scopus 로고
    • The encapsulation of microelectronic devices for long term surgical implantation
    • Donaldson PEK. The encapsulation of microelectronic devices for long term surgical implantation, IEEE Trans BME. 1976;23:281-285.
    • (1976) IEEE Trans BME , vol.23 , pp. 281-285
    • Donaldson, P.E.K.1
  • 23
    • 20244372369 scopus 로고    scopus 로고
    • Concept, design and fabrication of smart orthopedic implants
    • Burny F, Donkerwolcke M, Moulart F, et al. Concept, design and fabrication of smart orthopedic implants. Med Eng Phys. 2000;22: 469-479.
    • (2000) Med Eng Phys , vol.22 , pp. 469-479
    • Burny, F.1    Donkerwolcke, M.2    Moulart, F.3
  • 24
    • 4243520033 scopus 로고
    • The zero drift, a monitoring problem
    • Burny R, Puers F, eds. A Biomaterials Microelectronics-Challenge. Amsterdam: Elsevier
    • Donkerwolcke M, Burny F, Moulart F. The zero drift, a monitoring problem. In: Burny R, Puers F, eds. Monitoring of Orthopaedic Implants. A Biomaterials Microelectronics-Challenge. Amsterdam: Elsevier; 1993:89-124.
    • (1993) Monitoring of Orthopaedic Implants , pp. 89-124
    • Donkerwolcke, M.1    Burny, F.2    Moulart, F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.