메뉴 건너뛰기




Volumn 36, Issue 11, 2009, Pages 5228-5234

MRI of prostate brachytherapy seeds at high field: A study in phantom

Author keywords

3 Tesla; Brachytherapy; Field dependence; MRI

Indexed keywords

ONCOLOGY; PHANTOMS; RADIOTHERAPY; SPIN POLARIZATION; UROLOGY;

EID: 70350712617     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3244036     Document Type: Article
Times cited : (15)

References (9)
  • 1
    • 0030689702 scopus 로고    scopus 로고
    • Source localization following permanent transperineal prostate interstitial brachytherapy using magnetic resonance imaging
    • DOI 10.1016/S0360-3016(97)00501-4, PII S0360301697005014
    • D. F. Dubois, B. R. Prestidge, L. A. Hotchkiss, W. S. Bice, Jr., and J. J. Prete, " Source localization following permanent transperineal prostate interstitial brachytherapy using magnetic resonance imaging.," Int. J. Radiat. Oncol., Biol., Phys. 0360-3016 39, 1037-1041 (1997). 10.1016/S0360-3016(97)00501-4 (Pubitemid 27506155)
    • (1997) International Journal of Radiation Oncology Biology Physics , vol.39 , Issue.5 , pp. 1037-1041
    • Dubois, D.F.1    Prestidge, B.R.2    Hotchkiss, L.A.3    Bice Jr., W.S.4    Prete, J.J.5
  • 2
    • 0034996776 scopus 로고    scopus 로고
    • Brachytherapy for prostate cancer: Endorectal mr imaging of local treatment-related changes
    • F. V. Coakley, H. Hricak, A. E. Wefer, J. L. Speight, J. Kurhanewicz, and M. Roach III, " Brachytherapy for prostate cancer: Endorectal MR imaging of local treatment related changes.," Radiology 0033-8419 219, 817-821 (2001). (Pubitemid 32476279)
    • (2001) Radiology , vol.219 , Issue.3 , pp. 817-821
    • Coakley, F.V.1    Hricak, H.2    Wefer, A.E.3    Speight, J.L.4    Kurhanewicz, J.5    Roach III, M.6
  • 3
    • 0035188625 scopus 로고    scopus 로고
    • CT and MRI derived source localization error in a custom prostate phantom using automated image coregistration
    • DOI 10.1118/1.1406525
    • D. F. Dubois, W. S. Bice, Jr., and B. R. Prestige, " CT and MRI derived source localization error in a custom prostate phantom using automated image coregistration.," Med. Phys. 0094-2405 28, 2280-2284 (2001). 10.1118/1.1406525 (Pubitemid 33095560)
    • (2001) Medical Physics , vol.28 , Issue.11 , pp. 2280-2284
    • Dubois, D.F.1    Bice Jr., W.S.2    Prestige, B.R.3
  • 4
    • 33845312681 scopus 로고    scopus 로고
    • Characterization of the susceptibility artifact around a prostate brachytherapy seed in MRI
    • DOI 10.1118/1.2364052, 002612MPH
    • K. Wachowicz, S. D. Thomas, and B. G. Fallone, " Characterization of the susceptibility artifact around a prostate brachytherapy seed in MRI.," Med. Phys. 0094-2405 33, 4459-4467 (2006). 10.1118/1.2364052 (Pubitemid 44868082)
    • (2006) Medical Physics , vol.33 , Issue.12 , pp. 4459-4467
    • Wachowicz, K.1    Thomas, S.D.2    Fallone, B.G.3
  • 5
    • 0030013529 scopus 로고    scopus 로고
    • The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kinds
    • DOI 10.1118/1.597854
    • J. F. Schenck, " Review article: Role of magnetic susceptibility in MRI.," Med. Phys. 0094-2405 23, 815-850 (1996). 10.1118/1.597854 (Pubitemid 26192503)
    • (1996) Medical Physics , vol.23 , Issue.6 , pp. 815-850
    • Schenck, J.F.1
  • 6
    • 0022872540 scopus 로고
    • RARE imaging: A fast imaging method for clinical MR
    • 0740-3194,. 10.1002/mrm.1910030602
    • J. Hennig, A. Nauerth, and H. Friedburg, " RARE imaging: A fast imaging method for clinical MR.," Magn. Reson. Med. 0740-3194 3, 823-833 (1986). 10.1002/mrm.1910030602
    • (1986) Magn. Reson. Med. , vol.3 , pp. 823-833
    • Hennig, J.1    Nauerth, A.2    Friedburg, H.3
  • 7
    • 0002709709 scopus 로고
    • A comprehensive technical review of short TR, fast, magnetic resonance imaging
    • E. M. Haacke, P. A. Weilopolski, and J. A. Tkach, " A comprehensive technical review of short TR, fast, magnetic resonance imaging.," Rev. Magn. Reson. Med. 3, 53-170 (1991).
    • (1991) Rev. Magn. Reson. Med. , vol.3 , pp. 53-170
    • Haacke, E.M.1    Weilopolski, P.A.2    Tkach, J.A.3
  • 8
    • 18044367901 scopus 로고    scopus 로고
    • RF artifacts caused by metallic implants or instruments which get more prominent at 3 T: An in vitro study
    • DOI 10.1016/j.mri.2004.12.009
    • H. Graf, U. A. Lauer, A. Berger, and F. Schick, " RF artifacts caused by metallic implants or instruments which get more prominent at 3 T: An in vitro study.," Magn. Reson. Imaging 0730-725X 23, 493-499 (2005). 10.1016/j.mri.2004.12.009 (Pubitemid 40603341)
    • (2005) Magnetic Resonance Imaging , vol.23 , Issue.3 , pp. 493-499
    • Graf, H.1    Lauer, U.A.2    Berger, A.3    Schick, F.4
  • 9
    • 20344395132 scopus 로고    scopus 로고
    • Radio frequency versus susceptibility effects of small conductive implants - A systematic MRI study on aneurysm clips at 1.5 and 3 T
    • DOI 10.1016/j.mri.2005.02.012, PII S0730725X05001438
    • U. A. Lauer, H. Graf, A. Berger, C. D. Claussen, and F. Schick, " Radio frequency versus susceptibility effects of small conductive implants-A systematic MRI study on aneurysm clips at 1.5 and 3 T.," Magn. Reson. Imaging 0730-725X 23, 563-569 (2005). 10.1016/j.mri.2005.02.012 (Pubitemid 40779243)
    • (2005) Magnetic Resonance Imaging , vol.23 , Issue.4 , pp. 563-569
    • Lauer, U.A.1    Graf, H.2    Berger, A.3    Claussen, C.D.4    Schick, F.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.