Volumn 22, Issue , 2008, Pages 1738-1742

Towards noninvasive monitoring of total hemoglobin concentration and fractional oxygen saturation based on earlobe pulse oximetry

Author keywords

Blood constituents; Earlobe pulse oximeter; Hemoglobin concentration noninvasively; Monitoring of oxygen saturation

Indexed keywords

HEMOGLOBIN CONCENTRATION; HEMOGLOBIN CONCENTRATION NONINVASIVELY; HOME USE; INFRARED REGIONS; LAMBERT-BEER LAW; LOW PERFUSION; MOTION ARTIFACT; NON-INVASIVE MONITORING; NONINVASIVE MEASUREMENTS; OXYGEN SATURATION; PHOTOPLETHYSMOGRAPHY; PULSE OXIMETERS; PULSE OXIMETRY; PULSE WAVE VELOCITY; RELIABLE MEASUREMENT; TIME DELAY PROBLEM;

EID: 70350680661     PISSN: 16800737     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1007/978-3-540-89208-3_414     Document Type: Conference Paper
Times cited : (6)

References (11)
  • 4
    • 0032932450 scopus 로고    scopus 로고
    • Pulse Oximetry, Principles and Limitations
    • James E. Sinex (1999) Pulse Oximetry, Principles and Limitations, American Journal of Emergency Medicine, Volume 17, Number 1
    • (1999) American Journal of Emergency Medicine , vol.17 , Issue.1
    • Sinex, J.E.1
  • 5
    • 0038335187 scopus 로고    scopus 로고
    • Neonatal and Pediatric Pulse Oximetry
    • April
    • John W Sayler, (2003) Neonatal and Pediatric Pulse Oximetry, Respiratory Care, Vol 48, No 4, April
    • (2003) Respiratory Care , vol.48 , Issue.4
    • Sayler, J.W.1
  • 7
    • 34547568234 scopus 로고    scopus 로고
    • Selim S., Gregory C. John M. and Gregory J., (2007), NONINVASIVE DETERMINATION OF HEMOGLOBIN BY DIGITAL PHOTOGRAPHY OF PALPEBRAL CONJUNCTIVA, The Journal of Emergency Medicine, 33, No. 2, pp. 105-111.
    • Selim S., Gregory C. John M. and Gregory J., (2007), NONINVASIVE DETERMINATION OF HEMOGLOBIN BY DIGITAL PHOTOGRAPHY OF PALPEBRAL CONJUNCTIVA, The Journal of Emergency Medicine, Vol. 33, No. 2, pp. 105-111.
  • 8
    • 34047168047 scopus 로고    scopus 로고
    • Noninvasive measurement of total hemoglobin and hemoglobin derivatives using multiwavelength pulse spectrophotometry -In vitro study with a mock circulatory system-
    • New York City, USA
    • Hironori S., Kiyotaka I., Mitsuo U., Sunao T. and Tatsuo T., (2006),Noninvasive measurement of total hemoglobin and hemoglobin derivatives using multiwavelength pulse spectrophotometry -In vitro study with a mock circulatory system-, Proceedings of the 28th IEEE EMBS Annual International Conference New York City, USA
    • (2006) Proceedings of the 28th IEEE EMBS Annual International Conference
    • Hironori, S.1    Kiyotaka, I.2    Mitsuo, U.3    Sunao, T.4    Tatsuo, T.5
  • 9
    • 18744416257 scopus 로고    scopus 로고
    • J Kraitl, H Ewald and H Gehring, (2005) An optical device to measure blood components by a photoplethysmographic Method, J. Opt. A: Pure Appl. Opt. 7, S318-S324
    • J Kraitl, H Ewald and H Gehring, (2005) An optical device to measure blood components by a photoplethysmographic Method, J. Opt. A: Pure Appl. Opt. 7, S318-S324
  • 10
    • 0742303088 scopus 로고    scopus 로고
    • Design of filter to reject motion artifact of pulse oximetry
    • Lee, W. Jung, and G. Lee, (2004) "Design of filter to reject motion artifact of pulse oximetry," Comput. Standards Interfaces, vol. 26, pp. 241-249.
    • (2004) Comput. Standards Interfaces , vol.26 , pp. 241-249
    • Lee, W.J.1    Lee, G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.