메뉴 건너뛰기




Volumn 53, Issue 9, 2005, Pages 454-461

Modelling and control of the arterial blood flow during extracorporeal circulation;Modellierung und regelung des arteriellen blutflusses während der extrakorporalen zirkulation

Author keywords

Extracorporeal circulation; Heart lung machine; Robust control

Indexed keywords


EID: 70350640374     PISSN: 01782312     EISSN: None     Source Type: Journal    
DOI: 10.1524/auto.2005.53.9.454     Document Type: Article
Times cited : (3)

References (12)
  • 1
    • 8544250618 scopus 로고    scopus 로고
    • The Hemolysis Test of the Gyro C1E3 Pump in Pulsatile Mode”
    • Tayama, et al.: The Hemolysis Test of the Gyro C1E3 Pump in Pulsatile Mode”, Artif. Organs, 21(7) (1997), S. 675-679.
    • (1997) Artif. Organs , vol.21 , Issue.7 , pp. 675-679
    • Tayama1
  • 2
    • 85047679807 scopus 로고
    • Computation of haemodynamic power and input impedance in the ascending aorta of patients undergoing open heart surgery”
    • Wright, et al.: Computation of haemodynamic power and input impedance in the ascending aorta of patients undergoing open heart surgery”, Cardiovasc. Res., 22(3) (1988), S. 179-184.
    • (1988) Cardiovasc. Res , vol.22 , Issue.3 , pp. 179-184
    • Wright1
  • 3
    • 0003534827 scopus 로고
    • An elastic tube theory of pulse transmission and oscillatory flow in mammalian arteries”
    • J. R. Womersley: An elastic tube theory of pulse transmission and oscillatory flow in mammalian arteries”, WADC Technical Report, (1957), S. 56-614.
    • (1957) WADC Technical Report , pp. 56-614
    • Womersley, J.R.1
  • 4
    • 0014113777 scopus 로고
    • Difference-Differential Equations for Fluid Flow in Distensible Tubes”
    • V. C. Rideout und D. E. Dick: Difference-Differential Equations for Fluid Flow in Distensible Tubes”, IEEE Trans. Biomed Eng., 14(3) (1967), S. 171-177.
    • (1967) IEEE Trans. Biomed Eng , vol.14 , Issue.3 , pp. 171-177
    • Rideout, V.C.1    Dick, D.E.2
  • 5
    • 9444238864 scopus 로고
    • A hydraulic analog of the systemic and pulmonary circulation for testing artificial hearts”
    • Reul, et al.: A hydraulic analog of the systemic and pulmonary circulation for testing artificial hearts”, Proc. ESAO II., 2 (1975), S. 120-127.
    • (1975) Proc. ESAO II , vol.2 , pp. 120-127
    • Reul1
  • 6
    • 0019079690 scopus 로고
    • Multi-branched model of the human arterial system”
    • A. P. Avolio: Multi-branched model of the human arterial system”, Med. Biol. Eng. Comput., 18(6) (1980), S. 709-718.
    • (1980) Med. Biol. Eng. Comput , vol.18 , Issue.6 , pp. 709-718
    • Avolio, A.P.1
  • 7
    • 0015301264 scopus 로고
    • Cardiovascular system simulation in biomedical engineering education”
    • V. C. Rideout: Cardiovascular system simulation in biomedical engineering education”, IEEE Trans. Biomed Eng., 19(2) (1972), S. 101-107.
    • (1972) IEEE Trans. Biomed Eng , vol.19 , Issue.2 , pp. 101-107
    • Rideout, V.C.1
  • 9
    • 0031955516 scopus 로고    scopus 로고
    • Role and Relevancy of a Cardiovascular Simulator”
    • P. Segers, F. Dubois, D. De Wachter und P. Verdonck: Role and Relevancy of a Cardiovascular Simulator”, Cardiovasc. Eng., 3(1) (1998), S. 48-56.
    • (1998) Cardiovasc. Eng , vol.3 , Issue.1 , pp. 48-56
    • Segers, P.1    Dubois, F.2    De Wachter, D.3    Verdonck, P.4
  • 11
    • 0030059022 scopus 로고    scopus 로고
    • Propofol alters left ventricular afterload as evaluated by aortic input impedance in dogs”
    • Lowe, et al.: Propofol alters left ventricular afterload as evaluated by aortic input impedance in dogs”, Anesthesiology, 84(2) (1998), S. 368-376.
    • (1998) Anesthesiology , vol.84 , Issue.2 , pp. 368-376
    • Lowe1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.