메뉴 건너뛰기




Volumn 122, Issue 18, 2009, Pages 2174-2179

Vascular brachytherapy revisited for in-stent restenosis in the drug-eluting stent era: Current status and future perspective

Author keywords

Brachytherapy; Drug eluting stent; Percutaneous coronary intervention; Restenosis

Indexed keywords

ANTITHROMBOCYTIC AGENT; INDIUM 192; PHOSPHORUS 32; PLACEBO; RADIOISOTOPE; RHENIUM 188; STRONTIUM 90; UNCLASSIFIED DRUG; XENON 133; YTTRIUM;

EID: 70350588920     PISSN: 03666999     EISSN: None     Source Type: Journal    
DOI: 10.3760/cma.j.issn.0366-6999.2009.18.019     Document Type: Review
Times cited : (3)

References (37)
  • 1
    • 0035845633 scopus 로고    scopus 로고
    • Intravascular ultrasound assessment of the mechanisms and results of brachytherapy
    • Mintz GS, Weissman NJ, Fitzgerald PJ. Intravascular ultrasound assessment of the mechanisms and results of brachytherapy. Circulation 2001; 104: 1320-1325. (Pubitemid 32848124)
    • (2001) Circulation , vol.104 , Issue.11 , pp. 1320-1325
    • Mintz, G.S.1    Weissman, N.J.2    Fitzgerald, P.J.3
  • 2
    • 41849098150 scopus 로고    scopus 로고
    • Long-term outcomes after intracoronary beta-irradiation for in-stent restenosis in bare-metal stents
    • Maeder MT, Pfisterer ME, Buser PT, Roser HW, Roth J, Weilenmann D, et al. Long-term outcomes after intracoronary beta-irradiation for in-stent restenosis in bare-metal stents. J Invasive Cardiol 2008; 20: 179-184.
    • (2008) J Invasive Cardiol , vol.20 , pp. 179-184
    • Maeder, M.T.1    Pfisterer, M.E.2    Buser, P.T.3    Roser, H.W.4    Roth, J.5    Weilenmann, D.6
  • 3
    • 33644967633 scopus 로고    scopus 로고
    • Paclitaxel-eluting stents vs vascular brachytherapy for in-stent restenosis within bare-metal stents: The TAXUS V ISR randomized trial
    • Stone GW, Ellis SG, O'Shaughnessy CD, Martin SL, Satler L, McGarry T, et al. Paclitaxel-eluting stents vs vascular brachytherapy for in-stent restenosis within bare-metal stents: the TAXUS V ISR randomized trial. JAMA 2006; 295: 1253-1263.
    • (2006) JAMA , vol.295 , pp. 1253-1263
    • Stone, G.W.1    Ellis, S.G.2    O'Shaughnessy, C.D.3    Martin, S.L.4    Satler, L.5    McGarry, T.6
  • 4
    • 33644981694 scopus 로고    scopus 로고
    • Sirolimus-eluting stents vs vascular brachytherapy for in-stent restenosis within bare-metal stents: The SISR randomized trial
    • Holmes DR Jr, Teirstein P, Satler L, Sketch M, O'Malley J, Popma JJ, et al. Sirolimus-eluting stents vs vascular brachytherapy for in-stent restenosis within bare-metal stents: the SISR randomized trial. JAMA 2006; 295: 1264-1273.
    • (2006) JAMA , vol.295 , pp. 1264-1273
    • Holmes Jr., D.R.1    Teirstein, P.2    Satler, L.3    Sketch, M.4    O'Malley, J.5    Popma, J.J.6
  • 11
    • 0037116881 scopus 로고    scopus 로고
    • Use of localised intracoronary β radiation in treatment of in-stent restenosis: The INHIBIT randomised controlled trial
    • DOI 10.1016/S0140-6736(02)07741-3
    • Waksman R, Raizner AE, Yeung AC, Lansky AJ, Vandertie L. Use of localised intracoronary beta radiation in treatment of in-stent restenosis: the INHIBIT randomised controlled trial. Lancet 2002; 359: 551-557. (Pubitemid 34178435)
    • (2002) Lancet , vol.359 , Issue.9306 , pp. 551-557
    • Waksman, R.1    Raizner, A.E.2    Yeung, A.C.3    Lansky, A.J.4    Vandertie, L.5
  • 12
    • 0037426377 scopus 로고    scopus 로고
    • Intracoronary radiation therapy improves the clinical and angiographic outcomes of diffuse in-stent restenotic lesions: Results of the Washington Radiation for In-Stent Restenosis Trial for long lesions (Long WRIST) studies
    • DOI 10.1161/01.CIR.0000060497.91775.6D
    • Waksman R, Cheneau E, Ajani AE, White RL, Pinnow E, Torguson R, et al. Intracoronary radiation therapy improves the clinical and angiographic outcomes of diffuse in-stent restenotic lesions: results of the Washington Radiation for In-Stent Restenosis Trial for Long Lesions (Long WRIST) Studies. Circulation 2003; 107: 1744-1749. (Pubitemid 36418354)
    • (2003) Circulation , vol.107 , Issue.13 , pp. 1744-1749
    • Waksman, R.1    Cheneau, E.2    Ajani, A.E.3    White, R.L.4    Pinnow, E.5    Torguson, R.6    Deible, R.7    Satler, L.F.8    Pichard, A.D.9    Kent, K.M.10    Teirstein, P.S.11    Lindsay, J.12
  • 13
    • 0036777036 scopus 로고    scopus 로고
    • Serial intravascular ultrasound assessment of the efficacy of intracoronary gamma radiation for preventing recurrent in-stent restenosis
    • Ahmed JM. Serial intravascular ultrasound assessment of the efficacy of intracoronary gamma radiation for preventing recurrent in-stent restenosis. Minerva Cardioangiol 2002; 50: 507-515.
    • (2002) Minerva Cardioangiol , vol.50 , pp. 507-515
    • Ahmed, J.M.1
  • 23
    • 0031034495 scopus 로고    scopus 로고
    • Feasibility of intracoronary beta-irradiation to reduce restenosis after balloon angioplasty. A clinical pilot study
    • Verin V, Urban P, Popowski Y, Schwager M, Nouet P, Dorsaz PA, et al. Feasibility of intracoronary beta-irradiation to reduce restenosis after balloon angioplasty. A clinical pilot study. Circulation 1997; 95: 1138-1144.
    • (1997) Circulation , vol.95 , pp. 1138-1144
    • Verin, V.1    Urban, P.2    Popowski, Y.3    Schwager, M.4    Nouet, P.5    Dorsaz, P.A.6
  • 24
    • 0032568482 scopus 로고    scopus 로고
    • Endovascular beta-radiation to reduce restenosis after coronary balloon angioplasty: Results of the beta energy restenosis trial (BERT)
    • King SB 3rd, Williams DO, Chougule P, Klein JL, Waksman R, Hilstead R, et al. Endovascular beta-radiation to reduce restenosis after coronary balloon angioplasty: results of the beta energy restenosis trial (BERT). Circulation 1998; 97: 2025-2030.
    • (1998) Circulation , vol.97 , pp. 2025-2030
    • King III, S.B.1    Williams, D.O.2    Chougule, P.3    Klein, J.L.4    Waksman, R.5    Hilstead, R.6
  • 26
    • 0038677078 scopus 로고    scopus 로고
    • Intracoronary beta-irradiation with a rhenium-188-filled balloon catheter: A randomized trial in patients with de novo and restenotic lesions
    • Hoher M, Wohrle J, Wohlfrom M, Kamenz J, Nusser T, Grebe OC, et al. Intracoronary beta-irradiation with a rhenium-188-filled balloon catheter: a randomized trial in patients with de novo and restenotic lesions. Circulation 2003; 107: 3022-3027.
    • (2003) Circulation , vol.107 , pp. 3022-3027
    • Hoher, M.1    Wohrle, J.2    Wohlfrom, M.3    Kamenz, J.4    Nusser, T.5    Grebe, O.C.6
  • 27
    • 0042848518 scopus 로고    scopus 로고
    • Usefulness of beta radiation for de novo and in-stent restenotic lesions in saphenous vein grafts
    • Stone GW, Mehran R, Midei M, Waksman R, Schaer GL, Negoita M, et al. Usefulness of beta radiation for de novo and in-stent restenotic lesions in saphenous vein grafts. Am J Cardiol 2003; 92: 312-314.
    • (2003) Am J Cardiol , vol.92 , pp. 312-314
    • Stone, G.W.1    Mehran, R.2    Midei, M.3    Waksman, R.4    Schaer, G.L.5    Negoita, M.6
  • 28
    • 50849113064 scopus 로고    scopus 로고
    • Angiographic and intravascular ultrasound assessment of immediate and 9-month efficacy of percutaneous transluminal renal artery balloon angioplasty with subsequent brachytherapy in patients with renovascular hypertension
    • Lekston A, Chudek J, Gasior M, Wilczek K, Wiecek A, Kokot F, et al. Angiographic and intravascular ultrasound assessment of immediate and 9-month efficacy of percutaneous transluminal renal artery balloon angioplasty with subsequent brachytherapy in patients with renovascular hypertension. Kidney Blood Press Res 2008; 31: 291-298.
    • (2008) Kidney Blood Press Res , vol.31 , pp. 291-298
    • Lekston, A.1    Chudek, J.2    Gasior, M.3    Wilczek, K.4    Wiecek, A.5    Kokot, F.6
  • 29
    • 33846815294 scopus 로고    scopus 로고
    • Implementing a best-treatment strategy with intracoronary brachytherapy for in-stent restenosis in patients at high risk for recurrence
    • DOI 10.1016/j.carrev.2006.10.001, PII S1553838906002351
    • Kuiper KK, Salem M, Rotevatn S, Mills J , Nordrehaug JE. Implementing a best-treatment strategy with intracoronary brachytherapy for in-stent restenosis in patients at high risk for recurrence. Cardiovasc Revasc Med 2007; 8: 9-14. (Pubitemid 46216176)
    • (2007) Cardiovascular Revascularization Medicine , vol.8 , Issue.1 , pp. 9-14
    • Kuiper, K.K.J.1    Salem, M.2    Rotevatn, S.3    Mills, J.4    Nordrehaug, J.E.5
  • 33
    • 0037072461 scopus 로고    scopus 로고
    • Twelve versus six months of clopidogrel to reduce major cardiac events in patients undergoing gamma-radiation therapy for in-stent restenosis: Washington Radiation for In-Stent restenosis Trial (WRIST) 12 versus WRIST PLUS
    • Waksman R, Ajani AE, Pinnow E, Cheneau E, Leborgne L, Dieble R, et al. Twelve versus six months of clopidogrel to reduce major cardiac events in patients undergoing gamma-radiation therapy for in-stent restenosis: Washington Radiation for In-Stent restenosis Trial (WRIST) 12 versus WRIST PLUS. Circulation 2002; 106: 776-778.
    • (2002) Circulation , vol.106 , pp. 776-778
    • Waksman, R.1    Ajani, A.E.2    Pinnow, E.3    Cheneau, E.4    Leborgne, L.5    Dieble, R.6
  • 34
    • 42949152866 scopus 로고    scopus 로고
    • A meta-analysis of randomised controlled trials assessing drug-eluting stents and vascular brachytherapy in the treatment of coronary artery in-stent restenosis
    • DOI 10.1016/j.ijcard.2007.03.132, PII S0167527307008042
    • Oliver LN, Buttner PG, Hobson H, Golledge J. A meta-analysis of randomised controlled trials assessing drug-eluting stents and vascular brachytherapy in the treatment of coronary artery in-stent restenosis. Int J Cardiol 2008; 126: 216-223. (Pubitemid 351611666)
    • (2008) International Journal of Cardiology , vol.126 , Issue.2 , pp. 216-223
    • Oliver, L.N.1    Buttner, P.G.2    Hobson, H.3    Golledge, J.4
  • 35
    • 35348949074 scopus 로고    scopus 로고
    • Patients with in-stent restenoses: Comparison of intracoronary β-brachytherapy using a rhenium-188 filled balloon catheter with the polymer-based paclitaxel-eluting taxus-express stent
    • DOI 10.1160/nukmed-0084
    • Wohrle J, Nusser T, Krause BJ, Kochs M, Habig T, Mottaghy FM, et al. Patients with in-stent restenoses: comparison of intracoronary beta-brachytherapy using a rhenium-188 filled balloon catheter with the polymer-based paclitaxel-eluting taxus-express stent. Nuklearmedizin 2007; 46: 185-191. (Pubitemid 47612283)
    • (2007) NuklearMedizin , vol.46 , Issue.5 , pp. 185-191
    • Wohrle, J.1    Nusser, T.2    Krause, B.J.3    Kochs, M.4    Habig, T.5    Mottaghy, F.M.6    Kestler, H.A.7    Hombach, V.8    Reske, S.N.9
  • 36
    • 56349164629 scopus 로고    scopus 로고
    • Treatment of diffuse in-stent restenosis with drug-eluting stents vs intracoronary beta-radiation therapy: INDEED Study
    • Park SW, Lee SW, Koo BK, Park DW, Kim YH, Lee CW, et al. Treatment of diffuse in-stent restenosis with drug-eluting stents vs intracoronary beta-radiation therapy: INDEED Study. Int J Cardiol 2008; 131: 70-77.
    • (2008) Int J Cardiol , vol.131 , pp. 70-77
    • Park, S.W.1    Lee, S.W.2    Koo, B.K.3    Park, D.W.4    Kim, Y.H.5    Lee, C.W.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.