메뉴 건너뛰기




Volumn 116, Issue 11, 2009, Pages 2064-2071

Average 3-Dimensional Models for the Comparison of Orbscan II and Pentacam Pachymetry Maps in Normal Corneas

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTICLE; CONTROLLED STUDY; CORNEA THICKNESS; EQUIPMENT; HUMAN; HUMAN EXPERIMENT; INTERMETHOD COMPARISON; NORMAL HUMAN; PRIORITY JOURNAL; THREE DIMENSIONAL IMAGING; TOPOGRAPHY; ULTRASOUND;

EID: 70350570512     PISSN: 01616420     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ophtha.2009.04.036     Document Type: Article
Times cited : (54)

References (35)
  • 1
    • 0033759092 scopus 로고    scopus 로고
    • The repeatability of corneal thickness measures
    • Marsich M.W., and Bullimore M.A. The repeatability of corneal thickness measures. Cornea 19 (2000) 792-795
    • (2000) Cornea , vol.19 , pp. 792-795
    • Marsich, M.W.1    Bullimore, M.A.2
  • 2
    • 0021035876 scopus 로고
    • Evaluation and comparison of sources of variability in the measurement of corneal thickness with ultrasonic and optical pachymeters
    • Salz J.J., Azen S.P., Berstein J., et al. Evaluation and comparison of sources of variability in the measurement of corneal thickness with ultrasonic and optical pachymeters. Ophthalmic Surg 14 (1983) 750-754
    • (1983) Ophthalmic Surg , vol.14 , pp. 750-754
    • Salz, J.J.1    Azen, S.P.2    Berstein, J.3
  • 4
    • 0842331147 scopus 로고    scopus 로고
    • Corneal thickness: measurement and implications
    • Ehlers N., and Hjortdal J. Corneal thickness: measurement and implications. Exp Eye Res 78 (2004) 543-548
    • (2004) Exp Eye Res , vol.78 , pp. 543-548
    • Ehlers, N.1    Hjortdal, J.2
  • 5
    • 2342474638 scopus 로고    scopus 로고
    • Comparison of Orbscan and ultrasound pachymetry in the measurement of central corneal thickness [letter]
    • Radford S.W., Lim R., and Salmon J.F. Comparison of Orbscan and ultrasound pachymetry in the measurement of central corneal thickness [letter]. Eye 18 (2004) 434-436
    • (2004) Eye , vol.18 , pp. 434-436
    • Radford, S.W.1    Lim, R.2    Salmon, J.F.3
  • 6
    • 28044436542 scopus 로고    scopus 로고
    • Agreement and repeatability of central thickness measurement in normal corneas using ultrasound pachymetry and the OCULUS Pentacam
    • O'Donnell C., and Maldonado-Codina C. Agreement and repeatability of central thickness measurement in normal corneas using ultrasound pachymetry and the OCULUS Pentacam. Cornea 24 (2005) 920-924
    • (2005) Cornea , vol.24 , pp. 920-924
    • O'Donnell, C.1    Maldonado-Codina, C.2
  • 7
    • 33847225605 scopus 로고    scopus 로고
    • On the use of Orbscan II to assess the peripheral corneal thickness in humans: a comparison with ultrasound pachometry measures
    • Jonuscheit S., Doughty M.J., and Button N.F. On the use of Orbscan II to assess the peripheral corneal thickness in humans: a comparison with ultrasound pachometry measures. Ophthalmic Physiol Opt 27 (2007) 179-189
    • (2007) Ophthalmic Physiol Opt , vol.27 , pp. 179-189
    • Jonuscheit, S.1    Doughty, M.J.2    Button, N.F.3
  • 8
    • 0038650775 scopus 로고    scopus 로고
    • Comparison of central corneal thickness measurements by specular microscopy, ultrasound pachymetry, and ultrasound biomicroscopy
    • Tam E.S., and Rootman D.S. Comparison of central corneal thickness measurements by specular microscopy, ultrasound pachymetry, and ultrasound biomicroscopy. J Cataract Refract Surg 29 (2003) 1179-1184
    • (2003) J Cataract Refract Surg , vol.29 , pp. 1179-1184
    • Tam, E.S.1    Rootman, D.S.2
  • 9
    • 0042201932 scopus 로고    scopus 로고
    • Corneal thickness measurements: scanning-slit corneal topography and noncontact specular microscopy versus ultrasonic pachymetry
    • Suzuki S., Oshika T., Oki K., et al. Corneal thickness measurements: scanning-slit corneal topography and noncontact specular microscopy versus ultrasonic pachymetry. J Cataract Refract Surg 29 (2003) 1313-1318
    • (2003) J Cataract Refract Surg , vol.29 , pp. 1313-1318
    • Suzuki, S.1    Oshika, T.2    Oki, K.3
  • 10
    • 27144479245 scopus 로고    scopus 로고
    • Central corneal thickness measurement with the Pentacam Scheimpflug system, optical low-coherence reflectometry pachymeter, and ultrasound pachymetry
    • Barkana Y., Gerber Y., Elbaz U., et al. Central corneal thickness measurement with the Pentacam Scheimpflug system, optical low-coherence reflectometry pachymeter, and ultrasound pachymetry. J Cataract Refract Surg 31 (2005) 1729-1735
    • (2005) J Cataract Refract Surg , vol.31 , pp. 1729-1735
    • Barkana, Y.1    Gerber, Y.2    Elbaz, U.3
  • 11
    • 23944440178 scopus 로고    scopus 로고
    • Reliability of Orbscan II topography measurements in relation to refractive status
    • Rabsilber T.M., Becker K.A., and Auffarth G.U. Reliability of Orbscan II topography measurements in relation to refractive status. J Cataract Refract Surg 31 (2005) 1607-1613
    • (2005) J Cataract Refract Surg , vol.31 , pp. 1607-1613
    • Rabsilber, T.M.1    Becker, K.A.2    Auffarth, G.U.3
  • 12
    • 33847125749 scopus 로고    scopus 로고
    • Pentacam pachometry: comparison with non-contact specular microscopy on the central cornea and inter-session repeatability on the peripheral cornea
    • Lam A.K., and Chen D. Pentacam pachometry: comparison with non-contact specular microscopy on the central cornea and inter-session repeatability on the peripheral cornea. Clin Exp Optom 90 (2007) 108-114
    • (2007) Clin Exp Optom , vol.90 , pp. 108-114
    • Lam, A.K.1    Chen, D.2
  • 13
    • 37349056419 scopus 로고    scopus 로고
    • Anterior segment biometry with the Pentacam: comprehensive assessment of repeatability of automated measurements
    • Shankar H., Taranath D., Santhirathelagan C.T., and Pesudovs K. Anterior segment biometry with the Pentacam: comprehensive assessment of repeatability of automated measurements. J Cataract Refract Surg 34 (2008) 103-113
    • (2008) J Cataract Refract Surg , vol.34 , pp. 103-113
    • Shankar, H.1    Taranath, D.2    Santhirathelagan, C.T.3    Pesudovs, K.4
  • 15
    • 33847257295 scopus 로고    scopus 로고
    • Comparison of Pentacam Scheimpflug camera with ultrasound pachymetry and noncontact specular microscopy in measuring central corneal thickness
    • Fujioka M., Nakamura M., Tatsumi Y., et al. Comparison of Pentacam Scheimpflug camera with ultrasound pachymetry and noncontact specular microscopy in measuring central corneal thickness. Curr Eye Res 32 (2007) 89-94
    • (2007) Curr Eye Res , vol.32 , pp. 89-94
    • Fujioka, M.1    Nakamura, M.2    Tatsumi, Y.3
  • 16
    • 0037255230 scopus 로고    scopus 로고
    • Central and peripheral corneal thickness measurement with Orbscan II and topographical ultrasound pachymetry
    • Gonzalez-Meijome J.M., Cervino A., Yebra-Pimentel E., and Parafita M.A. Central and peripheral corneal thickness measurement with Orbscan II and topographical ultrasound pachymetry. J Cataract Refract Surg 29 (2003) 125-132
    • (2003) J Cataract Refract Surg , vol.29 , pp. 125-132
    • Gonzalez-Meijome, J.M.1    Cervino, A.2    Yebra-Pimentel, E.3    Parafita, M.A.4
  • 17
    • 33947575538 scopus 로고    scopus 로고
    • An assessment of regional differences in corneal thickness in normal human eyes, using the Orbscan II or ultrasound pachymetry
    • Doughty M.J., and Jonuscheit S. An assessment of regional differences in corneal thickness in normal human eyes, using the Orbscan II or ultrasound pachymetry. Optometry 78 (2007) 181-190
    • (2007) Optometry , vol.78 , pp. 181-190
    • Doughty, M.J.1    Jonuscheit, S.2
  • 18
    • 33845777965 scopus 로고    scopus 로고
    • Correction factor in Orbscan II in the assessment of corneal pachymetry
    • Cheng A.C., Tang E., Mohamed S., and Lam D.S. Correction factor in Orbscan II in the assessment of corneal pachymetry. Cornea 25 (2006) 1158-1161
    • (2006) Cornea , vol.25 , pp. 1158-1161
    • Cheng, A.C.1    Tang, E.2    Mohamed, S.3    Lam, D.S.4
  • 19
    • 33646906826 scopus 로고    scopus 로고
    • Comparison of central corneal thickness measurements by rotating Scheimpflug camera, ultrasonic pachymetry, and scanning-slit corneal topography
    • Amano S., Honda N., Amano Y., et al. Comparison of central corneal thickness measurements by rotating Scheimpflug camera, ultrasonic pachymetry, and scanning-slit corneal topography. Ophthalmology 113 (2006) 937-941
    • (2006) Ophthalmology , vol.113 , pp. 937-941
    • Amano, S.1    Honda, N.2    Amano, Y.3
  • 20
    • 34548748620 scopus 로고    scopus 로고
    • Central corneal thickness measurement with Pentacam, Orbscan II, and ultrasound devices before and after laser refractive surgery for myopia
    • Hashemi H., and Mehravaran S. Central corneal thickness measurement with Pentacam, Orbscan II, and ultrasound devices before and after laser refractive surgery for myopia. J Cataract Refract Surg 33 (2007) 1701-1707
    • (2007) J Cataract Refract Surg , vol.33 , pp. 1701-1707
    • Hashemi, H.1    Mehravaran, S.2
  • 21
    • 36448970833 scopus 로고    scopus 로고
    • Central corneal thickness measurements in unoperated eyes and eyes after PRK for myopia using Pentacam, Orbscan II, and ultrasonic pachymetry
    • Kim S.W., Byun Y.J., Kim E.K., and Kim T.I. Central corneal thickness measurements in unoperated eyes and eyes after PRK for myopia using Pentacam, Orbscan II, and ultrasonic pachymetry. J Refract Surg 23 (2007) 888-894
    • (2007) J Refract Surg , vol.23 , pp. 888-894
    • Kim, S.W.1    Byun, Y.J.2    Kim, E.K.3    Kim, T.I.4
  • 22
    • 29544440497 scopus 로고    scopus 로고
    • Comparison of three methods of measuring corneal thickness and anterior chamber depth
    • Buehl W., Stojanac D., Sacu S., et al. Comparison of three methods of measuring corneal thickness and anterior chamber depth. Am J Ophthalmol 141 (2006) 7-12
    • (2006) Am J Ophthalmol , vol.141 , pp. 7-12
    • Buehl, W.1    Stojanac, D.2    Sacu, S.3
  • 23
    • 36448955379 scopus 로고    scopus 로고
    • Comparison of central corneal thickness measured with Orbscan and Pentacam
    • Rosa N., Lanza M., Borrelli M., et al. Comparison of central corneal thickness measured with Orbscan and Pentacam. J Refract Surg 23 (2007) 895-899
    • (2007) J Refract Surg , vol.23 , pp. 895-899
    • Rosa, N.1    Lanza, M.2    Borrelli, M.3
  • 24
    • 51349166683 scopus 로고    scopus 로고
    • Comparison of central corneal thickness measurements by Orbscan II and Pentacam after corneal refractive surgery
    • Matsuda J., Hieda O., and Kinoshita S. Comparison of central corneal thickness measurements by Orbscan II and Pentacam after corneal refractive surgery. Jpn J Ophthalmol 52 (2008) 245-249
    • (2008) Jpn J Ophthalmol , vol.52 , pp. 245-249
    • Matsuda, J.1    Hieda, O.2    Kinoshita, S.3
  • 26
    • 0026588378 scopus 로고
    • Comparison of central corneal thickness measurements between optical and ultrasound pachometers
    • Giasson C., and Forthomme D. Comparison of central corneal thickness measurements between optical and ultrasound pachometers. Optom Vis Sci 69 (1992) 236-241
    • (1992) Optom Vis Sci , vol.69 , pp. 236-241
    • Giasson, C.1    Forthomme, D.2
  • 27
    • 0027673394 scopus 로고
    • Reproducibility and variation of corneal thickness in different locations in the cornea as measured by an ultrasonic pachymeter
    • Higgins S.E., Fishbaugh J.A., Strike D.J., and Rapuano C.J. Reproducibility and variation of corneal thickness in different locations in the cornea as measured by an ultrasonic pachymeter. Insight 18 (1993) 14-18
    • (1993) Insight , vol.18 , pp. 14-18
    • Higgins, S.E.1    Fishbaugh, J.A.2    Strike, D.J.3    Rapuano, C.J.4
  • 28
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland J.M., and Altman D.G. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1 (1986) 307-310
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 29
    • 0032884749 scopus 로고    scopus 로고
    • Measuring agreement in method comparison studies
    • Bland J.M., and Altman D.G. Measuring agreement in method comparison studies. Stat Methods Med Res 8 (1999) 135-160
    • (1999) Stat Methods Med Res , vol.8 , pp. 135-160
    • Bland, J.M.1    Altman, D.G.2
  • 30
    • 13944275573 scopus 로고    scopus 로고
    • Orbscan computerized topography: attributes, applications, and limitations
    • Cairns G., and McGhee C.N. Orbscan computerized topography: attributes, applications, and limitations. J Cataract Refract Surg 31 (2005) 205-220
    • (2005) J Cataract Refract Surg , vol.31 , pp. 205-220
    • Cairns, G.1    McGhee, C.N.2
  • 31
    • 48249104277 scopus 로고    scopus 로고
    • Diurnal variation of axial length, intraocular pressure, and anterior eye biometrics
    • Read S.A., Collins M.J., and Iskander D.R. Diurnal variation of axial length, intraocular pressure, and anterior eye biometrics. Invest Ophthalmol Vis Sci 49 (2008) 2911-2918
    • (2008) Invest Ophthalmol Vis Sci , vol.49 , pp. 2911-2918
    • Read, S.A.1    Collins, M.J.2    Iskander, D.R.3
  • 32
    • 0030477331 scopus 로고    scopus 로고
    • Diurnal variations in human corneal thickness
    • Harper C.L., Boulton M.E., Bennett D., et al. Diurnal variations in human corneal thickness. Br J Ophthalmol 80 (1996) 1068-1072
    • (1996) Br J Ophthalmol , vol.80 , pp. 1068-1072
    • Harper, C.L.1    Boulton, M.E.2    Bennett, D.3
  • 33
    • 27644542761 scopus 로고    scopus 로고
    • Repeatability and reproducibility of central corneal thickness measurement with Pentacam, Orbscan, and ultrasound
    • Lackner B., Schmidinger G., Pieh S., et al. Repeatability and reproducibility of central corneal thickness measurement with Pentacam, Orbscan, and ultrasound. Optom Vis Sci 82 (2005) 892-899
    • (2005) Optom Vis Sci , vol.82 , pp. 892-899
    • Lackner, B.1    Schmidinger, G.2    Pieh, S.3
  • 34
    • 0033898907 scopus 로고    scopus 로고
    • The cornea is not a piece of plastic
    • Roberts C. The cornea is not a piece of plastic. J Refract Surg 16 (2000) 407-413
    • (2000) J Refract Surg , vol.16 , pp. 407-413
    • Roberts, C.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.