메뉴 건너뛰기




Volumn 15, Issue 10, 2009, Pages 1247-1253

Early noninvasive measurement of the indocyanine green plasma disappearance rate accurately predicts early graft dysfunction and mortality after deceased donor liver transplantation

Author keywords

[No Author keywords available]

Indexed keywords

INDOCYANINE GREEN;

EID: 70350521239     PISSN: 15276465     EISSN: 15276473     Source Type: Journal    
DOI: 10.1002/lt.21841     Document Type: Article
Times cited : (41)

References (16)
  • 1
    • 0027932827 scopus 로고
    • A pilot study of indocyanine green clearance as an early predictor of graft function
    • Jalan R, Plevris JN, Jalan AR, Finlayson DC, Hayes PC. A pilot study of indocyanine green clearance as an early predictor of graft function. Transplantation 1994;58:196-200. (Pubitemid 24236214)
    • (1994) Transplantation , vol.58 , Issue.2 , pp. 196-200
    • Jalan, R.1    Plevris, J.N.2    Jalan, A.R.3    Finlayson, N.D.C.4    Hayes, P.C.5
  • 3
    • 0032922777 scopus 로고    scopus 로고
    • Indocyanine green clearance reflects reperfusion injury following liver transplantation and is an early predictor of graft function
    • DOI 10.1016/S0168-8278(99)80018-X
    • Plevris JN, Jalan R, Bzeizi KI, Dollinger MM, Lee A, Garden OJ, Hayes PC. Indocyanine green clearance reflects reperfusion injury following liver transplantation and is an early predictor of graft function. J Hepatol 1999;30:142-148. (Pubitemid 29023663)
    • (1999) Journal of Hepatology , vol.30 , Issue.1 , pp. 142-148
    • Plevris, J.N.1    Jalan, R.2    Bzeizi, K.I.3    Dollinger, M.M.4    Lee, A.5    Garden, O.J.6    Hayes, P.C.7
  • 4
    • 0030843690 scopus 로고    scopus 로고
    • Assessment of liver function: Pre- And peritransplant evaluation
    • Shaked A, Nunes FA, Olthoff KM, Lucey R. Assessment of liver function: pre- and peritransplant evaluation. Clin Chem 1997;43:1539-1545. (Pubitemid 27329813)
    • (1997) Clinical Chemistry , vol.43 , Issue.8 SUPPL. , pp. 1539-1545
    • Shaked, A.1    Nunes, F.A.2    Olthoff, K.M.3    Lucey, M.R.4
  • 5
    • 33644996504 scopus 로고    scopus 로고
    • Indocyanine green elimination: A comparison of the LIMON and serial blood sampling methods
    • Purcell R, Kruger P, Jones M. Indocyanine green elimination: a comparison of the LIMON and serial blood sampling methods. ANZ J Surg 2006;76:75-77.
    • (2006) ANZ J Surg , vol.76 , pp. 75-77
    • Purcell, R.1    Kruger, P.2    Jones, M.3
  • 6
    • 4544363070 scopus 로고    scopus 로고
    • Comparison of invasive and noninvasive measurement of plasma disappearance rate of indocyanine green in patients undergoing liver transplantation: A prospective investigator-blinded study
    • DOI 10.1002/lt.20205
    • Faybik P, Krenn CG, Baker A, Lahner D, Berlakovich G, Steltzer H, et al. Comparison of invasive and noninvasive measurement of plasma disappearance rate of indocyanine green in patients undergoing liver transplantation: a prospective investigator-blinded study. Liver Transpl 2004;10:1060-1064. (Pubitemid 39232762)
    • (2004) Liver Transplantation , vol.10 , Issue.8 , pp. 1060-1064
    • Faybik, P.1    Krenn, C.-G.2    Baker, A.3    Lahner, D.4    Berlakovich, G.5    Steltzer, H.6    Hetz, H.7
  • 7
    • 4344601159 scopus 로고    scopus 로고
    • Accuracy of indocyanine green pulse spectrophotometry clearance test for liver function prediction in transplanted patients
    • Hsieh CB, Chen CJ, Chen TW, Yu JC, Shen KL, Chang TM, et al. Accuracy of indocyanine green pulse spectrophotometry clearance test for liver function prediction in transplanted patients. World J Gastroenterol 2004;10:2394-2396.
    • (2004) World J Gastroenterol , vol.10 , pp. 2394-2396
    • Hsieh, C.B.1    Chen, C.J.2    Chen, T.W.3    Yu, J.C.4    Shen, K.L.5    Chang, T.M.6
  • 8
    • 33645538525 scopus 로고    scopus 로고
    • KICG value, a reliable real-time estimator of graft function, accurately predicts outcomes in adult living-donor liver transplantation
    • Hori T, Iida T, Yagi S, Taniguchi K, Yamamoto C, Mizuno S, et al. KICG value, a reliable real-time estimator of graft function, accurately predicts outcomes in adult living-donor liver transplantation. Liver Transpl 2006;12:605-613.
    • (2006) Liver Transpl , vol.12 , pp. 605-613
    • Hori, T.1    Iida, T.2    Yagi, S.3    Taniguchi, K.4    Yamamoto, C.5    Mizuno, S.6
  • 9
    • 0034933440 scopus 로고    scopus 로고
    • 1 and N-acetylcysteine on pediatric liver transplant recipients: A single-center study
    • DOI 10.1034/j.1399-3046.2001.005004274.x
    • Bucuvalas JC, Ryckman FC, Krug S, Alonso MH, Balistreri WF, Kotagal U. Effect of treatment with prostaglandin E1 and N-acetylcysteine in pediatric liver transplant recipients: a single-center study. Pediatr Transplant 2001;5:274-278. (Pubitemid 32661128)
    • (2001) Pediatric Transplantation , vol.5 , Issue.4 , pp. 274-278
    • Bucuvalas, J.C.1    Ryckman, F.C.2    Krug, S.3    Alonso, M.H.4    Balistreri, W.F.5    Kotagal, U.6
  • 10
    • 33645554185 scopus 로고    scopus 로고
    • Quantitative liver tests in living liver donors and their recipients
    • Reichen J. Quantitative liver tests in living liver donors and their recipients. Liver Transpl 2006;12:514-515.
    • (2006) Liver Transpl , vol.12 , pp. 514-515
    • Reichen, J.1
  • 11
    • 0038445276 scopus 로고    scopus 로고
    • Haemodynamic monitoring and liver function evaluation by pulsion cold system Z-201 (PCS) during orthotopic liver transplantation
    • DOI 10.1034/j.1399-0012.2003.02072.x
    • Díaz S, Pérez-Peña J, Sanz J, Olmedilla L, Garutti I, Barrio JM. Haemodynamic monitoring and liver function evaluation by pulsion cold system Z-201 (PCS) during orthotopic liver transplantation. Clin Transplant 2003;17:47-55. (Pubitemid 36621647)
    • (2003) Clinical Transplantation , vol.17 , Issue.1 , pp. 47-55
    • Diaz, S.1    Perez-Pena, J.2    Sanz, J.3    Olmedilla, L.4    Garutti, I.5    Barrio, J.M.6
  • 13
    • 0030878827 scopus 로고    scopus 로고
    • Hepatic microcirculation during human orthotopic liver transplantation
    • DOI 10.1002/bjs.1800841015
    • Seifalian AM, Rolles K, Davison BR. Hepatic microcirculation during human orthotopic liver transplantation. Br J Surg 1997;84:1391-1395. (Pubitemid 27443442)
    • (1997) British Journal of Surgery , vol.84 , Issue.10 , pp. 1391-1395
    • Seifalian, A.M.1    Mallet, S.V.2    Rolles, K.3    Davidson, B.R.4
  • 14
    • 0345530051 scopus 로고    scopus 로고
    • A survival-based scoring-system for initial graft function following orthotopic liver transplantation
    • DOI 10.1111/j.1432-2277.2003.tb00243.x
    • Heise M, Settmacher U, Pfitzmann R, Wünscher U, Müller AR, Jonas S, Neuhaus P. A survival-based scoring-system for initial graft function following orthotopic liver transplantation. Transpl Int 2003;16:794-800. (Pubitemid 37509415)
    • (2003) Transplant International , vol.16 , Issue.11 , pp. 794-800
    • Heise, M.1    Settmacher, U.2    Pfitzmann, R.3    Wunscher, U.4    Muller, A.R.5    Jonas, S.6    Neuhaus, P.7
  • 15
    • 0028092771 scopus 로고
    • Predictive values of early postoperative graft function in human liver transplantation
    • González FX, Rimola A, Grande L, Antolín M, Valdecasas G, Fuster J, et al. Predictive values of early postoperative graft function in human liver transplantation. Hepatology 1994;20:565-573.
    • (1994) Hepatology , vol.20 , pp. 565-573
    • González, F.X.1    Rimola, A.2    Grande, L.3    Antolín, M.4    Valdecasas, G.5    Fuster, J.6
  • 16
    • 38149082631 scopus 로고    scopus 로고
    • Indocyanine green plasma disappearance rate during the anhepatic phase of orthotopic liver transplantation
    • Bruegger L, Studer P, Schmid SW, Pestel G, Reichen J, Seiler C, et al. Indocyanine green plasma disappearance rate during the anhepatic phase of orthotopic liver transplantation. J Gastrointest Surg 2008;12:67-72.
    • (2008) J Gastrointest Surg , vol.12 , pp. 67-72
    • Bruegger, L.1    Studer, P.2    Schmid, S.W.3    Pestel, G.4    Reichen, J.5    Seiler, C.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.