1
-
-
20044389263
-
Recommendations from gynaecological (GYN) GEC-ESTRO working group (I): concepts and terms in 3D image based 3D treatment planning in cervix cancer brachytherapy with emphasis on MRI assessment of GTV and CTV
-
Haie-Meder C., Pötter R., Van Limbergen E., et al. Recommendations from gynaecological (GYN) GEC-ESTRO working group (I): concepts and terms in 3D image based 3D treatment planning in cervix cancer brachytherapy with emphasis on MRI assessment of GTV and CTV. Radiother Oncol 74 (2005) 235-245
-
(2005)
Radiother Oncol
, vol.74
, pp. 235-245
-
-
Haie-Meder, C.1
Pötter, R.2
Van Limbergen, E.3
-
2
-
-
31144452943
-
Recommendations from gynaecological (GYN) GEC ESTRO working group (II): concepts and terms in 3D image-based treatment planning in cervix cancer brachytherapy-3D dose volume parameters and aspects of 3D image-based anatomy, radiation physics, radiobiology
-
Pötter R., Haie-Meder C., Van Limbergen E., et al. Recommendations from gynaecological (GYN) GEC ESTRO working group (II): concepts and terms in 3D image-based treatment planning in cervix cancer brachytherapy-3D dose volume parameters and aspects of 3D image-based anatomy, radiation physics, radiobiology. Radiother Oncol 78 (2006) 67-77
-
(2006)
Radiother Oncol
, vol.78
, pp. 67-77
-
-
Pötter, R.1
Haie-Meder, C.2
Van Limbergen, E.3
-
3
-
-
49149085806
-
Potential of dose optimisation in MRI-based PDR brachytherapy of cervix carcinoma
-
De Brabandere M., Mousa A.G., Nulens A., et al. Potential of dose optimisation in MRI-based PDR brachytherapy of cervix carcinoma. Radiother Oncol 88 (2008) 217-226
-
(2008)
Radiother Oncol
, vol.88
, pp. 217-226
-
-
De Brabandere, M.1
Mousa, A.G.2
Nulens, A.3
-
4
-
-
33646233996
-
The Vienna applicator for combined intracavitary and interstitial brachytherapy of cervical cancer: design, application, treatment planning, and dosimetric results
-
Kirisits C., Lang S., Dimopoulos J., Berger D., Georg D., and Pötter R. The Vienna applicator for combined intracavitary and interstitial brachytherapy of cervical cancer: design, application, treatment planning, and dosimetric results. Int J Radiat Oncol Biol Phys 65 (2006) 624-630
-
(2006)
Int J Radiat Oncol Biol Phys
, vol.65
, pp. 624-630
-
-
Kirisits, C.1
Lang, S.2
Dimopoulos, J.3
Berger, D.4
Georg, D.5
Pötter, R.6
-
5
-
-
44449163974
-
MRI-guided 3D optimization significantly improves DVH parameters of pulsed-dose-rate brachytherapy in locally advanced cervical cancer
-
Lindegaard J.C., Tanderup K., Nielsen S.K., Haack S., and Gelineck J. MRI-guided 3D optimization significantly improves DVH parameters of pulsed-dose-rate brachytherapy in locally advanced cervical cancer. Int J Radiat Oncol Biol Phys 71 (2008) 756-764
-
(2008)
Int J Radiat Oncol Biol Phys
, vol.71
, pp. 756-764
-
-
Lindegaard, J.C.1
Tanderup, K.2
Nielsen, S.K.3
Haack, S.4
Gelineck, J.5
-
6
-
-
65449176362
-
Applicator reconstruction in MRI 3D image-based dose planning of brachytherapy for cervical cancer
-
Haack S., Nielsen S.K., Lindegaard J.C., Gelineck J., and Tanderup K. Applicator reconstruction in MRI 3D image-based dose planning of brachytherapy for cervical cancer. Radiother Oncol 91 (2009) 187-193
-
(2009)
Radiother Oncol
, vol.91
, pp. 187-193
-
-
Haack, S.1
Nielsen, S.K.2
Lindegaard, J.C.3
Gelineck, J.4
Tanderup, K.5
-
7
-
-
65449162208
-
Exclusive MRI-based tandem and colpostats reconstruction in gynaecological brachytherapy treatment planning
-
Perez-Calatayud J., Kuipers F., Ballester F., et al. Exclusive MRI-based tandem and colpostats reconstruction in gynaecological brachytherapy treatment planning. Radiother Oncol 91 (2009) 181-186
-
(2009)
Radiother Oncol
, vol.91
, pp. 181-186
-
-
Perez-Calatayud, J.1
Kuipers, F.2
Ballester, F.3
-
8
-
-
33947496319
-
Uncertainties in assessment of the vaginal dose for intracavitary brachytherapy of cervical cancer using a tandem-ring applicator
-
Berger D., Dimopoulos J., Georg P., Georg D., Potter R., and Kirisits C. Uncertainties in assessment of the vaginal dose for intracavitary brachytherapy of cervical cancer using a tandem-ring applicator. Int J Radiat Oncol Biol Phys 67 (2007) 1451-1459
-
(2007)
Int J Radiat Oncol Biol Phys
, vol.67
, pp. 1451-1459
-
-
Berger, D.1
Dimopoulos, J.2
Georg, P.3
Georg, D.4
Potter, R.5
Kirisits, C.6
-
9
-
-
34547746023
-
Reconstruction of a ring applicator using CT imaging: impact of the reconstruction method and applicator orientation
-
Hellebust T.P., Tanderup K., Bergstrand E.S., Knutsen B.H., Røislien J., and Olsen D.R. Reconstruction of a ring applicator using CT imaging: impact of the reconstruction method and applicator orientation. Phys Med Biol 52 (2007) 4893-4904
-
(2007)
Phys Med Biol
, vol.52
, pp. 4893-4904
-
-
Hellebust, T.P.1
Tanderup, K.2
Bergstrand, E.S.3
Knutsen, B.H.4
Røislien, J.5
Olsen, D.R.6
-
10
-
-
51049112572
-
Consequences of random and systematic reconstruction uncertainties in 3D image based brachytherapy in cervical caner
-
Tanderup K., Hellebrust T.P., Lang S., et al. Consequences of random and systematic reconstruction uncertainties in 3D image based brachytherapy in cervical caner. Radiother Oncol 89 (2008) 156-163
-
(2008)
Radiother Oncol
, vol.89
, pp. 156-163
-
-
Tanderup, K.1
Hellebrust, T.P.2
Lang, S.3
-
11
-
-
29244455321
-
"Volumetool": an image evaluation, registration, and delineation system for radiotherapy
-
Bol G.H., Kotte A.N.T.J., and Lagendijk J.J.W. "Volumetool": an image evaluation, registration, and delineation system for radiotherapy. Phys Med 19 (2003) 80
-
(2003)
Phys Med
, vol.19
, pp. 80
-
-
Bol, G.H.1
Kotte, A.N.T.J.2
Lagendijk, J.J.W.3
-
12
-
-
0004011789
-
Dose and volume specification for reporting intracavitary therapy in gynecology. International Commission on Radiation Units and Measurements
-
No. 38, Bethesda, MD;
-
ICRU Report No. 38. Dose and volume specification for reporting intracavitary therapy in gynecology. International Commission on Radiation Units and Measurements, Bethesda, MD; 1985.
-
(1985)
ICRU Report
-
-
-
13
-
-
20344407033
-
Dose and volume parameters for MRI-based treatment planning in intracavitary brachytherapy for cervical cancer
-
Kirisits C., Pötter R., Lang S., et al. Dose and volume parameters for MRI-based treatment planning in intracavitary brachytherapy for cervical cancer. Int J Radiat Oncol Biol Phys 62 (2005) 901-911
-
(2005)
Int J Radiat Oncol Biol Phys
, vol.62
, pp. 901-911
-
-
Kirisits, C.1
Pötter, R.2
Lang, S.3
-
14
-
-
34548473370
-
Treatment planning for MRI assisted brachytherapy of gynecologic malignancies based on total dose constraints
-
Lang S., Kirisits C., Dimopoulos J., Georg D., and Pötter R. Treatment planning for MRI assisted brachytherapy of gynecologic malignancies based on total dose constraints. Int J Radiat Oncol Biol Phys 69 (2007) 619-627
-
(2007)
Int J Radiat Oncol Biol Phys
, vol.69
, pp. 619-627
-
-
Lang, S.1
Kirisits, C.2
Dimopoulos, J.3
Georg, D.4
Pötter, R.5
-
15
-
-
70350457105
-
Present status and future of high-precision image guided adaptive brachytherapy for cervix carcinoma
-
Pötter R., Kirisits C., Fidarova E.F., et al. Present status and future of high-precision image guided adaptive brachytherapy for cervix carcinoma. Acta Oncol 25 (2008) 1-12
-
(2008)
Acta Oncol
, vol.25
, pp. 1-12
-
-
Pötter, R.1
Kirisits, C.2
Fidarova, E.F.3
-
16
-
-
70350476635
-
Intrafraction motion of the primary CTV in patients with cervical cancer: an assessment by repeated MR imaging
-
Kerkhof E.M., van der Put R.W., Raaymakers B.W., van der Heide U.A., Ju"rgenliemk-Schulz I.M., and Lagendijk J.J.W. Intrafraction motion of the primary CTV in patients with cervical cancer: an assessment by repeated MR imaging. Radiother Oncol 88 (2008) S108
-
(2008)
Radiother Oncol
, vol.88
-
-
Kerkhof, E.M.1
van der Put, R.W.2
Raaymakers, B.W.3
van der Heide, U.A.4
Jurgenliemk-Schulz, I.M.5
Lagendijk, J.J.W.6
-
17
-
-
33845332103
-
Uncertainties when using only one MRI-based treatment plan for subsequent high-dose-rate tandem and ring applications in brachytherapy of cervix cancer
-
Kirisits C., Lang S., Dimopoulos J., Oechs K., Georg D., and Pötter R. Uncertainties when using only one MRI-based treatment plan for subsequent high-dose-rate tandem and ring applications in brachytherapy of cervix cancer. Radiother Oncol 81 (2006) 269-275
-
(2006)
Radiother Oncol
, vol.81
, pp. 269-275
-
-
Kirisits, C.1
Lang, S.2
Dimopoulos, J.3
Oechs, K.4
Georg, D.5
Pötter, R.6
-
18
-
-
0034881451
-
Inter fraction variations in rectum and bladder volumes and dose distributions during high dose rate brachytherapy treatment of the uterine cervix investigated by repetitive CT-examinations
-
Hellebust T.P., Dale E., Skjonsberg A., and Olsen D.R. Inter fraction variations in rectum and bladder volumes and dose distributions during high dose rate brachytherapy treatment of the uterine cervix investigated by repetitive CT-examinations. Radiother Oncol 60 (2001) 273-280
-
(2001)
Radiother Oncol
, vol.60
, pp. 273-280
-
-
Hellebust, T.P.1
Dale, E.2
Skjonsberg, A.3
Olsen, D.R.4
-
19
-
-
34548382663
-
Accuracy of volume and DVH parameters determined with different brachytherapy treatment planning systems
-
Kirisits C., Sieber F.A., Baltas D., et al. Accuracy of volume and DVH parameters determined with different brachytherapy treatment planning systems. Radiother Oncol 84 (2007) 290-297
-
(2007)
Radiother Oncol
, vol.84
, pp. 290-297
-
-
Kirisits, C.1
Sieber, F.A.2
Baltas, D.3
-
20
-
-
0034237827
-
Inter-observer variation in delineation of bladder and rectum contours for brachytherapy of cervical cancer
-
Saarnak A.E., Boersma M., van Bunningen B.N., Woltering R., and Steggerda M.J. Inter-observer variation in delineation of bladder and rectum contours for brachytherapy of cervical cancer. Radiother Oncol 56 (2000) 37-42
-
(2000)
Radiother Oncol
, vol.56
, pp. 37-42
-
-
Saarnak, A.E.1
Boersma, M.2
van Bunningen, B.N.3
Woltering, R.4
Steggerda, M.J.5
-
21
-
-
51049099674
-
Inter- and intraobserver variation in HR-CTV contouring: intercomparison of transverse and paratransverse image orientation in 3D-MRI assisted cervix cancer brachytherapy
-
Petric P., Dimopoulos J., Kirisits C., Berger D., Hudej R., and Potter R. Inter- and intraobserver variation in HR-CTV contouring: intercomparison of transverse and paratransverse image orientation in 3D-MRI assisted cervix cancer brachytherapy. Radiother Oncol 89 (2009) 164-171
-
(2009)
Radiother Oncol
, vol.89
, pp. 164-171
-
-
Petric, P.1
Dimopoulos, J.2
Kirisits, C.3
Berger, D.4
Hudej, R.5
Potter, R.6
-
22
-
-
34247844654
-
Computed tomography versus magnetic resonance imaging-based contouring in cervical cancer brachytherapy: results of a prospective trial and preliminary guidelines for standardized contours
-
Viswanathan A.N., Dimopoulos J., Kirisits C., Berger D., and Pötter R. Computed tomography versus magnetic resonance imaging-based contouring in cervical cancer brachytherapy: results of a prospective trial and preliminary guidelines for standardized contours. Int J Radiat Oncol Biol Phys 68 (2007) 491-498
-
(2007)
Int J Radiat Oncol Biol Phys
, vol.68
, pp. 491-498
-
-
Viswanathan, A.N.1
Dimopoulos, J.2
Kirisits, C.3
Berger, D.4
Pötter, R.5
-
24
-
-
34249091765
-
Clinical impact of MRI assisted dose volume adaptation and dose escalation in brachytherapy of locally advanced cervix cancer
-
Pötter R., Dimopoulos J., Georg P., et al. Clinical impact of MRI assisted dose volume adaptation and dose escalation in brachytherapy of locally advanced cervix cancer. Radiother Oncol 83 (2007) 148-155
-
(2007)
Radiother Oncol
, vol.83
, pp. 148-155
-
-
Pötter, R.1
Dimopoulos, J.2
Georg, P.3
-
25
-
-
33746832046
-
The Vienna applicator for combined intracavitary and interstitial brachytherapy of cervical cancer: clinical feasibility and preliminary results
-
Dimopoulos J.C., Kirisits C., Petric P., et al. The Vienna applicator for combined intracavitary and interstitial brachytherapy of cervical cancer: clinical feasibility and preliminary results. Int J Radiat Oncol Biol Phys 66 (2006) 83-90
-
(2006)
Int J Radiat Oncol Biol Phys
, vol.66
, pp. 83-90
-
-
Dimopoulos, J.C.1
Kirisits, C.2
Petric, P.3
|