메뉴 건너뛰기




Volumn 48, Issue 5, 2009, Pages 271-276

Equivalent threshold sound pressure levels (ETSPL) for Sennheiser HDA 280 supra-aural audiometric earphones in the frequency range 125 Hz to 8000 Hz

Author keywords

Audiometry; Calibration; ETSPL; HDA 280; Hearing threshold

Indexed keywords

ADULT; AGE DISTRIBUTION; ARTICLE; AUDIOMETRY; AUDITORY DISCRIMINATION; AUDITORY THRESHOLD; CONTROLLED STUDY; FEMALE; FREQUENCY DISCRIMINATION; HEARING TEST; HUMAN; LABORATORY TEST; MALE; PRIORITY JOURNAL; SEX DIFFERENCE; SOUND PRESSURE;

EID: 70350494509     PISSN: 14992027     EISSN: 17088186     Source Type: Journal    
DOI: 10.1080/14992020902788982     Document Type: Article
Times cited : (10)

References (19)
  • 1
    • 0024790126 scopus 로고
    • Reference equivalent threshold sound pressure levels for insert earphones
    • Arlinger, S. & Kinnefors, C. 1989. Reference equivalent threshold sound pressure levels for insert earphones. Scand Audiol, 18, 195-198.
    • (1989) Scand Audiol , vol.18 , pp. 195-198
    • Arlinger, S.1    Kinnefors, C.2
  • 2
    • 54049110542 scopus 로고
    • Reference zero for the calibration of pure tone audiometers equipped with insert earphones
    • Brinkmann, K. & Richter, U. 1990. Reference zero for the calibration of pure tone audiometers equipped with insert earphones. Acustica, 70, 202-207.
    • (1990) Acustica , vol.70 , pp. 202-207
    • Brinkmann, K.1    Richter, U.2
  • 3
    • 0031800510 scopus 로고    scopus 로고
    • Equivalent threshold sound pressure levels for Sennheiser HDA 200 earphone and Etymotic Research ER-2 insert earphone in the Frequency range 125 Hz to 16 kHz
    • Han, L.A. & Poulsen, T. 1998. Equivalent threshold sound pressure levels for Sennheiser HDA 200 earphone and Etymotic Research ER-2 insert earphone in the Frequency range 125 Hz to 16 kHz. Scand Audiol, 27, 105-112.
    • (1998) Scand Audiol , vol.27 , pp. 105-112
    • Han, L.A.1    Poulsen, T.2
  • 15
    • 0025813163 scopus 로고
    • Reference thresholds for Eartone 3A insert earphones
    • Poulsen, T. 1991. Reference thresholds for Eartone 3A insert earphones. Scand Audiol, 20, 205-207.
    • (1991) Scand Audiol , vol.20 , pp. 205-207
    • Poulsen, T.1
  • 16
    • 54049112626 scopus 로고    scopus 로고
    • Reference hearing threshold levels for short duration signals
    • Poulsen, T. & Legarth, S.V. 2008. Reference hearing threshold levels for short duration signals. Int J Audiol, 47, 665-674.
    • (2008) Int J Audiol , vol.47 , pp. 665-674
    • Poulsen, T.1    Legarth, S.V.2
  • 18
    • 70350449895 scopus 로고    scopus 로고
    • HDA 280 Instructions for use. Retrieved 25 January, 2009
    • Sennheiser. 2003. HDA 280 Instructions for use. Retrieved 25 January, 2009, from http://www.sennheiser.com/sennheiser/home-en.nsf/product.html? ReadForm&path-professional-audiology&product- 009860&row-1.
    • (2003)


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.