메뉴 건너뛰기




Volumn 16, Issue 12, 2009, Pages 1502-1508

Peripheral Intravenous Power Injection of Iodinated Contrast Media. The Impact of Temperature on Maximum Injection Pressures at Different Cannula Sizes

Author keywords

injection pressure; intravenous cannula; Iodinated contrast media; power injection

Indexed keywords

IOMEPROL; IOPAMIDOL;

EID: 70350464945     PISSN: 10766332     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.acra.2009.07.026     Document Type: Article
Times cited : (12)

References (32)
  • 1
    • 33644604990 scopus 로고    scopus 로고
    • How to design injection protocols for multiple detector-row CT angiography (MDCTA)
    • Fleischmann D. How to design injection protocols for multiple detector-row CT angiography (MDCTA). Eur Radiol 15 suppl (2005) E60-E65
    • (2005) Eur Radiol , vol.15 , Issue.SUPPL
    • Fleischmann, D.1
  • 2
    • 58949098775 scopus 로고    scopus 로고
    • Optimal vascular and parenchymal contrast enhancement: the current state of the art
    • Fleischmann D., and Kamaya A. Optimal vascular and parenchymal contrast enhancement: the current state of the art. Radiol Clin North Am 47 (2009) 13-26
    • (2009) Radiol Clin North Am , vol.47 , pp. 13-26
    • Fleischmann, D.1    Kamaya, A.2
  • 3
    • 34447498780 scopus 로고    scopus 로고
    • CT perfusion for the monitoring of neoadjuvant chemotherapy and radiation therapy in rectal carcinoma: initial experience
    • Bellomi M., Petralia G., Sonzogni A., et al. CT perfusion for the monitoring of neoadjuvant chemotherapy and radiation therapy in rectal carcinoma: initial experience. Radiology 244 (2007) 486-493
    • (2007) Radiology , vol.244 , pp. 486-493
    • Bellomi, M.1    Petralia, G.2    Sonzogni, A.3
  • 4
    • 0038790375 scopus 로고    scopus 로고
    • Quantitative perfusion imaging by multi-slice CT in stroke patients
    • [article in German]
    • Bohner G., Forschler A., Hamm B., et al. Quantitative perfusion imaging by multi-slice CT in stroke patients. [article in German]. Rofo 175 (2003) 806-813
    • (2003) Rofo , vol.175 , pp. 806-813
    • Bohner, G.1    Forschler, A.2    Hamm, B.3
  • 5
    • 34250817485 scopus 로고    scopus 로고
    • Sixty-four slice CT evaluation of aortic stenosis using planimetry of the aortic valve area
    • Feuchtner G.M., Muller S., Bonatti J., et al. Sixty-four slice CT evaluation of aortic stenosis using planimetry of the aortic valve area. AJR Am J Roentgenol 189 (2007) 197-203
    • (2007) AJR Am J Roentgenol , vol.189 , pp. 197-203
    • Feuchtner, G.M.1    Muller, S.2    Bonatti, J.3
  • 6
    • 34250888834 scopus 로고    scopus 로고
    • Significant coronary artery stenosis: comparison on per-patient and per-vessel or per-segment basis at 64-section CT angiography
    • Herzog C., Zwerner P.L., Doll J.R., et al. Significant coronary artery stenosis: comparison on per-patient and per-vessel or per-segment basis at 64-section CT angiography. Radiology 244 (2007) 112-120
    • (2007) Radiology , vol.244 , pp. 112-120
    • Herzog, C.1    Zwerner, P.L.2    Doll, J.R.3
  • 7
    • 36348943499 scopus 로고    scopus 로고
    • Multi-detector row computed tomography angiography of peripheral arterial disease
    • Kock M.C., Dijkshoorn M.L., Pattynama P.M., et al. Multi-detector row computed tomography angiography of peripheral arterial disease. Eur Radiol 17 (2007) 3208-3222
    • (2007) Eur Radiol , vol.17 , pp. 3208-3222
    • Kock, M.C.1    Dijkshoorn, M.L.2    Pattynama, P.M.3
  • 8
    • 39049156813 scopus 로고    scopus 로고
    • ECG-gated chest CT angiography with 64-MDCT and tri-phasic IV contrast administration regimen in patients with acute non-specific chest pain
    • Litmanovitch D., Zamboni G.A., Hauser T.H., et al. ECG-gated chest CT angiography with 64-MDCT and tri-phasic IV contrast administration regimen in patients with acute non-specific chest pain. Eur Radiol 18 (2008) 308-317
    • (2008) Eur Radiol , vol.18 , pp. 308-317
    • Litmanovitch, D.1    Zamboni, G.A.2    Hauser, T.H.3
  • 9
    • 34447644026 scopus 로고    scopus 로고
    • The contribution of perfusion CT in stroke
    • [article in Portuguese]
    • Lopes L., Sousa R., Ruivo J., et al. The contribution of perfusion CT in stroke. [article in Portuguese]. Acta Med Port 19 (2006) 484-488
    • (2006) Acta Med Port , vol.19 , pp. 484-488
    • Lopes, L.1    Sousa, R.2    Ruivo, J.3
  • 11
    • 34547607793 scopus 로고    scopus 로고
    • Cardiac CT angiography after coronary bypass surgery: prevalence of incidental findings
    • Mueller J., Jeudy J., Poston R., et al. Cardiac CT angiography after coronary bypass surgery: prevalence of incidental findings. AJR Am J Roentgenol 189 (2007) 414-419
    • (2007) AJR Am J Roentgenol , vol.189 , pp. 414-419
    • Mueller, J.1    Jeudy, J.2    Poston, R.3
  • 12
    • 33845741615 scopus 로고    scopus 로고
    • 16-MDCT angiography in living kidney donors at various tube potentials: impact on image quality and radiation dose
    • Sahani D.V., Kalva S.P., Hahn P.F., et al. 16-MDCT angiography in living kidney donors at various tube potentials: impact on image quality and radiation dose. AJR Am J Roentgenol 188 (2007) 115-120
    • (2007) AJR Am J Roentgenol , vol.188 , pp. 115-120
    • Sahani, D.V.1    Kalva, S.P.2    Hahn, P.F.3
  • 13
    • 34547670928 scopus 로고    scopus 로고
    • Accuracy of 64-slice computed tomography for the preoperative detection of coronary artery disease in patients with chronic aortic regurgitation
    • Scheffel H., Leschka S., Plass A., et al. Accuracy of 64-slice computed tomography for the preoperative detection of coronary artery disease in patients with chronic aortic regurgitation. Am J Cardiol 100 (2007) 701-706
    • (2007) Am J Cardiol , vol.100 , pp. 701-706
    • Scheffel, H.1    Leschka, S.2    Plass, A.3
  • 14
    • 33847265364 scopus 로고    scopus 로고
    • Assessment of left ventricular function and mass in patients undergoing computed tomography (CT) coronary angiography using 64-detector-row CT: comparison to magnetic resonance imaging
    • Schlosser T., Mohrs O.K., Magedanz A., et al. Assessment of left ventricular function and mass in patients undergoing computed tomography (CT) coronary angiography using 64-detector-row CT: comparison to magnetic resonance imaging. Acta Radiol 48 (2007) 30-35
    • (2007) Acta Radiol , vol.48 , pp. 30-35
    • Schlosser, T.1    Mohrs, O.K.2    Magedanz, A.3
  • 15
    • 33748998438 scopus 로고    scopus 로고
    • MDCT angiography of the pulmonary arteries: influence of body weight, body mass index, and scan length on arterial enhancement at different iodine flow rates
    • Schoellnast H., Deutschmann H.A., Berghold A., et al. MDCT angiography of the pulmonary arteries: influence of body weight, body mass index, and scan length on arterial enhancement at different iodine flow rates. AJR Am J Roentgenol 187 (2006) 1074-1078
    • (2006) AJR Am J Roentgenol , vol.187 , pp. 1074-1078
    • Schoellnast, H.1    Deutschmann, H.A.2    Berghold, A.3
  • 16
    • 33748535757 scopus 로고    scopus 로고
    • Comparison of enhancement, image quality, cost, and adverse reactions using 2 different contrast medium concentrations for routine chest CT on 16-slice MDCT
    • Setty B.N., Sahani D.V., Ouellette-Piazzo K., et al. Comparison of enhancement, image quality, cost, and adverse reactions using 2 different contrast medium concentrations for routine chest CT on 16-slice MDCT. J Comput Assist Tomogr 30 (2006) 818-822
    • (2006) J Comput Assist Tomogr , vol.30 , pp. 818-822
    • Setty, B.N.1    Sahani, D.V.2    Ouellette-Piazzo, K.3
  • 17
    • 34548150139 scopus 로고    scopus 로고
    • Increasing contrast agent concentration improves enhancement in first-pass CT perfusion
    • Silvennoinen H.M., Hamberg L.M., Valanne L., et al. Increasing contrast agent concentration improves enhancement in first-pass CT perfusion. AJNR Am J Neuroradiol 28 (2007) 1299-1303
    • (2007) AJNR Am J Neuroradiol , vol.28 , pp. 1299-1303
    • Silvennoinen, H.M.1    Hamberg, L.M.2    Valanne, L.3
  • 18
    • 33847647566 scopus 로고    scopus 로고
    • Perfusion CT in acute stroke: predictive value of perfusion parameters in assessing tissue viability versus infarction
    • Sparacia G., Iaia A., Assadi B., et al. Perfusion CT in acute stroke: predictive value of perfusion parameters in assessing tissue viability versus infarction. Radiol Med (Torino) 112 (2007) 113-122
    • (2007) Radiol Med (Torino) , vol.112 , pp. 113-122
    • Sparacia, G.1    Iaia, A.2    Assadi, B.3
  • 19
    • 0028885944 scopus 로고
    • Effects of viscosity, cannula size and temperature in mechanical contrast media administration in CT and magnetic resonance tomography [article in German]
    • Knopp M., Kauczor H.U., Knopp M.A., et al. Effects of viscosity, cannula size and temperature in mechanical contrast media administration in CT and magnetic resonance tomography [article in German]. Rofo 163 (1995) 259-264
    • (1995) Rofo , vol.163 , pp. 259-264
    • Knopp, M.1    Kauczor, H.U.2    Knopp, M.A.3
  • 20
    • 0023213358 scopus 로고
    • Heating contrast media: role in contemporary angiography
    • Halsell R.D. Heating contrast media: role in contemporary angiography. Radiology 164 (1987) 276-278
    • (1987) Radiology , vol.164 , pp. 276-278
    • Halsell, R.D.1
  • 21
    • 0023155819 scopus 로고
    • Heating contrast media in a microwave oven
    • Halsell R.D. Heating contrast media in a microwave oven. Radiology 163 (1987) 279-280
    • (1987) Radiology , vol.163 , pp. 279-280
    • Halsell, R.D.1
  • 22
    • 63649141070 scopus 로고    scopus 로고
    • Peripheral intravenous power injection of iodinated contrast media through 22G and 20G cannulas: can high flow rates be achieved safely? A clinical feasibility study
    • Schwab S.A., Uder M., Anders K., et al. Peripheral intravenous power injection of iodinated contrast media through 22G and 20G cannulas: can high flow rates be achieved safely? A clinical feasibility study. Rofo 181 (2009) 355-361
    • (2009) Rofo , vol.181 , pp. 355-361
    • Schwab, S.A.1    Uder, M.2    Anders, K.3
  • 23
    • 0026750883 scopus 로고
    • Safety considerations in the power injection of contrast media via central venous catheters during computed tomographic examinations
    • Carlson J.E., Hedlund L.J., Trenkner S.W., et al. Safety considerations in the power injection of contrast media via central venous catheters during computed tomographic examinations. Invest Radiol 27 (1992) 337-340
    • (1992) Invest Radiol , vol.27 , pp. 337-340
    • Carlson, J.E.1    Hedlund, L.J.2    Trenkner, S.W.3
  • 24
    • 26944435912 scopus 로고    scopus 로고
    • Contrast media pressure injection using a portal catheter system-results of an in vitro study
    • [article in German]
    • Gebauer B., Teichgraber U.K., Hothan T., et al. Contrast media pressure injection using a portal catheter system-results of an in vitro study. [article in German]. Rofo 177 (2005) 1417-1423
    • (2005) Rofo , vol.177 , pp. 1417-1423
    • Gebauer, B.1    Teichgraber, U.K.2    Hothan, T.3
  • 25
    • 0029787206 scopus 로고    scopus 로고
    • Power injection of intravenous contrast material through central venous catheters for CT: in vitro evaluation
    • Herts B.R., Cohen M.A., McInroy B., et al. Power injection of intravenous contrast material through central venous catheters for CT: in vitro evaluation. Radiology 200 (1996) 731-735
    • (1996) Radiology , vol.200 , pp. 731-735
    • Herts, B.R.1    Cohen, M.A.2    McInroy, B.3
  • 26
    • 12644291951 scopus 로고    scopus 로고
    • Power injection of peripherally inserted central catheters
    • Rivitz S.M., and Drucker E.A. Power injection of peripherally inserted central catheters. J Vasc Interv Radiol 8 (1997) 857-863
    • (1997) J Vasc Interv Radiol , vol.8 , pp. 857-863
    • Rivitz, S.M.1    Drucker, E.A.2
  • 27
    • 0030950253 scopus 로고    scopus 로고
    • In-line pressures generated in small-bore central venous catheters during power injection of CT contrast media
    • Ruess L., Bulas D.I., Rivera O., et al. In-line pressures generated in small-bore central venous catheters during power injection of CT contrast media. Radiology 203 (1997) 625-629
    • (1997) Radiology , vol.203 , pp. 625-629
    • Ruess, L.1    Bulas, D.I.2    Rivera, O.3
  • 28
    • 1542343919 scopus 로고    scopus 로고
    • Maximal flow rates possible during power injection through currently available PICCs: an in vitro study
    • Salis A.I., Eclavea A., Johnson M.S., et al. Maximal flow rates possible during power injection through currently available PICCs: an in vitro study. J Vasc Interv Radiol 15 (2004) 275-281
    • (2004) J Vasc Interv Radiol , vol.15 , pp. 275-281
    • Salis, A.I.1    Eclavea, A.2    Johnson, M.S.3
  • 29
    • 16644399038 scopus 로고    scopus 로고
    • Safety and feasibility of using a central venous catheter for rapid contrast injection rates
    • Sanelli P.C., Deshmukh M., Ougorets I., et al. Safety and feasibility of using a central venous catheter for rapid contrast injection rates. AJR Am J Roentgenol 183 (2004) 1829-1834
    • (2004) AJR Am J Roentgenol , vol.183 , pp. 1829-1834
    • Sanelli, P.C.1    Deshmukh, M.2    Ougorets, I.3
  • 30
    • 0035183174 scopus 로고    scopus 로고
    • Assessing the adequacy of peripherally inserted central catheters for power injection of intravenous contrast agents for CT
    • Williamson E.E., and McKinney J.M. Assessing the adequacy of peripherally inserted central catheters for power injection of intravenous contrast agents for CT. J Comput Assist Tomogr 25 (2001) 932-937
    • (2001) J Comput Assist Tomogr , vol.25 , pp. 932-937
    • Williamson, E.E.1    McKinney, J.M.2
  • 31
    • 34047272661 scopus 로고    scopus 로고
    • Injection rate threshold of triple-lumen central venous catheters: an in vitro study
    • Zamos D.T., Emch T.M., Patton H.A., et al. Injection rate threshold of triple-lumen central venous catheters: an in vitro study. Acad Radiol 14 (2007) 574-578
    • (2007) Acad Radiol , vol.14 , pp. 574-578
    • Zamos, D.T.1    Emch, T.M.2    Patton, H.A.3
  • 32
    • 3042530832 scopus 로고    scopus 로고
    • Iodine delivery rate of different concentrations of iodine-containing contrast agents with rapid injection
    • [article in German]
    • Knollmann F., Schimpf K., and Felix R. Iodine delivery rate of different concentrations of iodine-containing contrast agents with rapid injection. [article in German]. Rofo 176 (2004) 880-884
    • (2004) Rofo , vol.176 , pp. 880-884
    • Knollmann, F.1    Schimpf, K.2    Felix, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.