메뉴 건너뛰기




Volumn 103, Issue 4, 2009, Pages 614-615

Four cases of anaphylaxis to chlorhexidine impregnated central venous catheters: A case cluster or the tip of the iceberg?

Author keywords

[No Author keywords available]

Indexed keywords

ADRENALIN; ANTIHISTAMINIC AGENT; CHLORHEXIDINE; IMMUNOGLOBULIN E; STEROID; SULFADIAZINE SILVER; TRYPTASE; BIOMATERIAL; TOPICAL ANTIINFECTIVE AGENT;

EID: 70350450630     PISSN: 00070912     EISSN: 14716771     Source Type: Journal    
DOI: 10.1093/bja/aep248     Document Type: Letter
Times cited : (50)

References (10)
  • 1
    • 0038545378 scopus 로고    scopus 로고
    • Is there a risk of sensitization and allergy to chlorhexidine in health care workers?
    • Garvey L, Roed-Petersen J, Husum B. Is there a risk of sensitization and allergy to chlorhexidine in health care workers? Acta Anaesthesiol Scand 2003; 47: 720-724
    • (2003) Acta Anaesthesiol Scand , vol.47 , pp. 720-724
    • Garvey, L.1    Roed-Petersen, J.2    Husum, B.3
  • 2
    • 84998382740 scopus 로고
    • Four cases presenting anaphylactic reactions due to topical application of Hibitanew
    • Okano M, Nomura M, Okada N, Sato K, Tashiro M. Four cases presenting anaphylactic reactions due to topical application of Hibitanew. Skin Res 1983; 25: 587-592
    • (1983) Skin Res , vol.25 , pp. 587-592
    • Okano, M.1    Nomura, M.2    Okada, N.3    Sato, K.4    Tashiro, M.5
  • 3
    • 0027990552 scopus 로고
    • Anaphylactic shock by ophthalmic wash solution containing chlorhexidine
    • Okuda T, Funasaka M, Arimitsu M, Umeda T, Wakita K, Koga Y. Anaphylactic shock by ophthalmic wash solution containing chlorhexidine. Masui 1994; 43: 1352-1355
    • (1994) Masui , vol.43 , pp. 1352-1355
    • Okuda, T.1    Funasaka, M.2    Arimitsu, M.3    Umeda, T.4    Wakita, K.5    Koga, Y.6
  • 4
    • 15444366304 scopus 로고    scopus 로고
    • Anaphylaxis to an urethral lubricant: Chlorhexidine as the 'hidden' allergen
    • Ebo DG, Bridts CH, Stevens WJ. Anaphylaxis to an urethral lubricant: chlorhexidine as the 'hidden' allergen. Acta Clin Belg 2004; 59: 358-360
    • (2004) Acta Clin Belg , vol.59 , pp. 358-360
    • Ebo, D.G.1    Bridts, C.H.2    Stevens, W.J.3
  • 5
    • 57349143560 scopus 로고    scopus 로고
    • Anaphylaxis to the chlorhexidine component of Instillagelw: A case series
    • Parkes AW, Harper N, Herwadker A, Pumphrey R. Anaphylaxis to the chlorhexidine component of Instillagelw: a case series. Br J Anaesth 2009; 102: 65-68
    • (2009) Br J Anaesth , vol.102 , pp. 65-68
    • Parkes, A.W.1    Harper, N.2    Herwadker, A.3    Pumphrey, R.4
  • 6
    • 46849108912 scopus 로고    scopus 로고
    • A case of anaphylaxis to chlorhexidine during digital rectal examination
    • Bae YJ, Park CS, Lee JK, et al. A case of anaphylaxis to chlorhexidine during digital rectal examination. J Korean Med Sci 2008; 23: 526-528
    • (2008) J Korean Med Sci , vol.23 , pp. 526-528
    • Bae, Y.J.1    Park, C.S.2    Lee, J.K.3
  • 7
    • 0030929384 scopus 로고    scopus 로고
    • Intranasal chlorhexidine resulting in anaphylactic circulatory arrest
    • Chisholm DG, Calder I, Peterson D, Powell M, Moult P. Intranasal chlorhexidine resulting in anaphylactic circulatory arrest. Br Med J 1997; 315: 785
    • (1997) Br Med J , vol.315 , pp. 785
    • Chisholm, D.G.1    Calder, I.2    Peterson, D.3    Powell, M.4    Moult, P.5
  • 9
    • 2342509501 scopus 로고    scopus 로고
    • Immediate hypersensitivity to chlorhexidine: Literature review
    • Beaudouin E, Kanny G, Morisset M, et al. Immediate hypersensitivity to chlorhexidine: literature review. Allerg Immunol 2004; 36: 123-126
    • (2004) Allerg Immunol , vol.36 , pp. 123-126
    • Beaudouin, E.1    Kanny, G.2    Morisset, M.3
  • 10
    • 0034879071 scopus 로고    scopus 로고
    • Two episodes of life-threatening anaphylaxis in the same patient to a chlorhexidine-sulphadiazine-coated central venous catheter
    • Stephens R, Mythen M, Kallis P, Davies DWL, Egner W, Rickards A. Two episodes of life-threatening anaphylaxis in the same patient to a chlorhexidine-sulphadiazine-coated central venous catheter. Br J Anaesth 2001; 87: 306-308
    • (2001) Br J Anaesth , vol.87 , pp. 306-308
    • Stephens, R.1    Mythen, M.2    Kallis, P.3    Davies, D.W.L.4    Egner, W.5    Rickards, A.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.