메뉴 건너뛰기




Volumn , Issue , 2009, Pages 3106-3109

A bio-impedance measurement system for portable monitoring of heart rate and pulse wave velocity using small body area

Author keywords

[No Author keywords available]

Indexed keywords

ANALOG CIRCUITRY; BIOIMPEDANCE MEASUREMENT; CONTINUOUS MONITORING; DISCRETE COMPONENTS; HEART FAILURE; HEART PUMP; HEART RATES; INPUT IMPEDANCE; OPTIMUM LOCATION; PHYSIOLOGICAL RANGE; PORTABLE MONITORING; PULSE WAVE VELOCITY; RADIAL ARTERY; REFERENCE DEVICES; SIGNAL QUALITY; SMALL BODIES; SYSTEM SENSITIVITY;

EID: 70350443597     PISSN: 02714310     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ISCAS.2009.5118460     Document Type: Conference Paper
Times cited : (64)

References (13)
  • 2
    • 0032898657 scopus 로고    scopus 로고
    • Aortic pulse wave velocity as a marker of cardiovascular risk in hypertensive patients
    • May
    • J. Blacher, R. Asmar, S. Djane, G. M. London, and M. E. Safar, "Aortic pulse wave velocity as a marker of cardiovascular risk in hypertensive patients," Hypertension, vol. 33, no. 5, pp. 1111-1117, May 1999.
    • (1999) Hypertension , vol.33 , Issue.5 , pp. 1111-1117
    • Blacher, J.1    Asmar, R.2    Djane, S.3    London, G.M.4    Safar, M.E.5
  • 3
    • 34247467602 scopus 로고    scopus 로고
    • Photoplethysmography and its application in clinical physiological measurement
    • Mar
    • J. Allen, "Photoplethysmography and its application in clinical physiological measurement," Physiol. Meas., vol. 28, no. 3, pp. R1-R39, Mar 2007.
    • (2007) Physiol. Meas , vol.28 , Issue.3
    • Allen, J.1
  • 5
    • 0030964357 scopus 로고    scopus 로고
    • Bioelectrical impedance techniques in medicine: Bioimpedance measurement
    • M. E. Valentinuzzi, "Bioelectrical impedance techniques in medicine: Bioimpedance measurement," Crit. Rev. Biomed. Eng., vol. 24, pp. 223-255, 1996.
    • (1996) Crit. Rev. Biomed. Eng , vol.24 , pp. 223-255
    • Valentinuzzi, M.E.1
  • 6
    • 0027595685 scopus 로고
    • Impedance plethysmography for the evaluation of pulse-wave velocity in limbs
    • May
    • F. Risacher and ohters, "Impedance plethysmography for the evaluation of pulse-wave velocity in limbs," Med. Biol. Eng. Comput., vol. 31, pp. 318-322, May 1993.
    • (1993) Med. Biol. Eng. Comput , vol.31 , pp. 318-322
    • Risacher, F.1    ohters2
  • 8
    • 0027715230 scopus 로고
    • AC instrumentation amplifier for bioimpedance measurements
    • Aug
    • R. Pallàs-Areny and J. G. Webster, "AC instrumentation amplifier for bioimpedance measurements," IEEE Trans. Bio-Med. Eng., vol. 40, no. 8, pp. 830-833, Aug 1993.
    • (1993) IEEE Trans. Bio-Med. Eng , vol.40 , Issue.8 , pp. 830-833
    • Pallàs-Areny, R.1    Webster, J.G.2
  • 10
    • 39749194436 scopus 로고    scopus 로고
    • Heart rate detection from plantar bioimpedance measurements
    • Mar
    • R. González-Landaeta, O. Casas, and R. Pallàs-Areny, "Heart rate detection from plantar bioimpedance measurements," IEEE Trans. BioMed. Eng., vol. 55, no. 3, pp. 1163-1167, Mar 2008.
    • (2008) IEEE Trans. BioMed. Eng , vol.55 , Issue.3 , pp. 1163-1167
    • González-Landaeta, R.1    Casas, O.2    Pallàs-Areny, R.3
  • 11
    • 29344472604 scopus 로고    scopus 로고
    • A tissue impedance measurement chip for myocardial ischemia detection
    • Dec
    • A. Yúfera et al., "A tissue impedance measurement chip for myocardial ischemia detection," IEEE Trans. Circuits Syst. I, vol. 52, no. 12, pp. 2620-2628, Dec 2005.
    • (2005) IEEE Trans. Circuits Syst. I , vol.52 , Issue.12 , pp. 2620-2628
    • Yúfera, A.1
  • 13
    • 36349029588 scopus 로고    scopus 로고
    • An energy-efficient micropower neural recording amplifier
    • Jun
    • W. Wattanapanitch, M. Fee, and R. Sarpeshkar, "An energy-efficient micropower neural recording amplifier," IEEE Trans. Biomed. Circuits Syst., vol. 1, no. 2, pp. 136-147, Jun 2007.
    • (2007) IEEE Trans. Biomed. Circuits Syst , vol.1 , Issue.2 , pp. 136-147
    • Wattanapanitch, W.1    Fee, M.2    Sarpeshkar, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.