메뉴 건너뛰기




Volumn 29, Issue 6, 2009, Pages 385-391

Blood flow rate measurements with indicator techniques revisited

Author keywords

Assumptions; Blood flow rate; Cardiac output; Heat as indicator; Indicator kinetics; Indicators; Regional distribution volume; Washout rate

Indexed keywords

ARM; BLOOD FLOW VELOCITY; BRAIN; DISTRIBUTION VOLUME; HEART OUTPUT; HUMAN; INDICATOR DILUTION CURVE; INFUSION; INTESTINE; KIDNEY; LEG; LIVER; MEASUREMENT; METABOLIC SYNDROME X; PATHOGENESIS; PRIORITY JOURNAL; REVIEW; STEADY STATE;

EID: 70350409571     PISSN: 14750961     EISSN: 1475097X     Source Type: Journal    
DOI: 10.1111/j.1475-097X.2009.00886.x     Document Type: Review
Times cited : (4)

References (28)
  • 1
    • 0022270890 scopus 로고
    • Maximal perfusion of skeletal muscle in man
    • Andersen P, Saltin B. Maximal perfusion of skeletal muscle in man. J Physiol 1985, 366:233-249.
    • (1985) J Physiol , vol.366 , pp. 233-249
    • Andersen, P.1    Saltin, B.2
  • 2
    • 0013769403 scopus 로고
    • Tracer dynamics and the determination of pool-sizes and turnover factors in metabolic systems
    • Bergner PE. Tracer dynamics and the determination of pool-sizes and turnover factors in metabolic systems. J Theor Biol 1964, 6:137-158.
    • (1964) J Theor Biol , vol.6 , pp. 137-158
    • Bergner, P.E.1
  • 3
    • 0035221847 scopus 로고    scopus 로고
    • Measurement of adipose tissue blood flow
    • Bülow J. Measurement of adipose tissue blood flow. Methods Mol Biol 2001, 155:281-293.
    • (2001) Methods Mol Biol , vol.155 , pp. 281-293
    • Bülow, J.1
  • 4
    • 0002049738 scopus 로고
    • Über die Messung des Blutquantums in den Hertzventrikeln
    • Fick A. Über die Messung des Blutquantums in den Hertzventrikeln. Verh Phys Med Ges Würtzburg 1870, 2:16.
    • (1870) Verh Phys Med Ges Würtzburg , vol.2 , pp. 16
    • Fick, A.1
  • 5
    • 0001669568 scopus 로고
    • Simultaneous determination of the pulmonary and systemic circulation times in man and of a figure related to the cardiac output
    • Hamilton WF, Moore J, Kinsman JM, Spurling RG. Simultaneous determination of the pulmonary and systemic circulation times in man and of a figure related to the cardiac output. Am J Physiol 1928a, 84:338-344.
    • (1928) Am J Physiol , vol.84 , pp. 338-344
    • Hamilton, W.F.1    Moore, J.2    Kinsman, J.M.3    Spurling, R.G.4
  • 6
    • 0000586628 scopus 로고
    • Simultaneous determinations of the greater and lesser circulation times, of the mean velocity of blood flow through the heart and lungs, of the cardiac output and an approximation of the amount of blood activity circulating in the heart and lungs
    • Hamilton WF, Moore JW, Kinsman JM, Spurling RG. Simultaneous determinations of the greater and lesser circulation times, of the mean velocity of blood flow through the heart and lungs, of the cardiac output and an approximation of the amount of blood activity circulating in the heart and lungs. Am J Physiol 1928b, 85:377-378.
    • (1928) Am J Physiol , vol.85 , pp. 377-378
    • Hamilton, W.F.1    Moore, J.W.2    Kinsman, J.M.3    Spurling, R.G.4
  • 7
    • 0000138437 scopus 로고
    • Studies of the circulation IV. Further analysis of the injection method, and of changes in hemodynamics under physiological and pathological conditions
    • Hamilton WF, Moore JW, Kinsman JM, Spurling RG. Studies of the circulation IV. Further analysis of the injection method, and of changes in hemodynamics under physiological and pathological conditions. Am J Physiol 1932, 99:534-551.
    • (1932) Am J Physiol , vol.99 , pp. 534-551
    • Hamilton, W.F.1    Moore, J.W.2    Kinsman, J.M.3    Spurling, R.G.4
  • 9
    • 15244359671 scopus 로고    scopus 로고
    • Detection of early central circulatory transits in patients with cirrhosis by gamma variate fit of indicator dilution profiles
    • Henriksen JH, Møller S, Fuglsang S, Bendtsen F. Detection of early central circulatory transits in patients with cirrhosis by gamma variate fit of indicator dilution profiles. Am J Physiol Gastrointest Liver Physiol 2005, 288:G677-G684.
    • (2005) Am J Physiol Gastrointest Liver Physiol , vol.288
    • Henriksen, J.H.1    Møller, S.2    Fuglsang, S.3    Bendtsen, F.4
  • 10
    • 0344437373 scopus 로고
    • Über die Verteilung des Blutes vom linken Herzen zwishchen dem herzen und dem übrigen Organismus
    • Henriques V. Über die Verteilung des Blutes vom linken Herzen zwishchen dem herzen und dem übrigen Organismus. Biochem Zeitscher 1913, 56:230-248.
    • (1913) Biochem Zeitscher , vol.56 , pp. 230-248
    • Henriques, V.1
  • 11
    • 0023759111 scopus 로고
    • Measurement of skeletal muscle blood flow in humans: plethysmographic, bolus and continuous infusion technique
    • Jorfeldt LS. Measurement of skeletal muscle blood flow in humans: plethysmographic, bolus and continuous infusion technique. Am J Cardiol 1988, 62:25E-29E.
    • (1988) Am J Cardiol , vol.62
    • Jorfeldt, L.S.1
  • 12
    • 0018096083 scopus 로고
    • Determination of human leg blood flow: a thermodilution technique based on femoral venous bolus injection
    • Jorfeldt L, Juhlin-Dannfelt A, Pernow B, Wassen E. Determination of human leg blood flow: a thermodilution technique based on femoral venous bolus injection. Clin Sci Mol Med 1978, 54:517-523.
    • (1978) Clin Sci Mol Med , vol.54 , pp. 517-523
    • Jorfeldt, L.1    Juhlin-Dannfelt, A.2    Pernow, B.3    Wassen, E.4
  • 13
    • 0015441098 scopus 로고
    • Measurement of relative blood flow, transit-time distributions and transport-model parameters by residue detection when radiotracer recirculates
    • Larson KB, Snyder DL. Measurement of relative blood flow, transit-time distributions and transport-model parameters by residue detection when radiotracer recirculates. J Theor Biol 1972, 37:503-529.
    • (1972) J Theor Biol , vol.37 , pp. 503-529
    • Larson, K.B.1    Snyder, D.L.2
  • 14
    • 0023265209 scopus 로고
    • Cerebral blood flow measured by xenon-133
    • Lassen NA. Cerebral blood flow measured by xenon-133. Nucl Med Commun 1987, 8:535-547.
    • (1987) Nucl Med Commun , vol.8 , pp. 535-547
    • Lassen, N.A.1
  • 15
    • 0015092649 scopus 로고
    • Monoexponential extrapolation of tracer clearance curves in kinetic analysis
    • Lassen NA, Sejrsen P. Monoexponential extrapolation of tracer clearance curves in kinetic analysis. Circ Res 1971, 29:76-87.
    • (1971) Circ Res , vol.29 , pp. 76-87
    • Lassen, N.A.1    Sejrsen, P.2
  • 16
    • 0002199381 scopus 로고
    • Indicator methods for measurement of organ and tissue blood flow
    • In, eds, pp, American Physiological Society, Bethesda, MD
    • Lassen NA, Henriksen O, Sejrsen P, Shepherd JT, Abboud FM. Indicator methods for measurement of organ and tissue blood flow. The Cardiovascular System III 1983, 21-63. In, eds, pp, American Physiological Society, Bethesda, MD
    • (1983) The Cardiovascular System III , pp. 21-63
    • Lassen, N.A.1    Henriksen, O.2    Sejrsen, P.3    Shepherd, J.T.4    Abboud, F.M.5
  • 17
    • 77049181625 scopus 로고
    • On the theory of the indicator-dilution method for measurement of blood flow and volume
    • Meier P, Zierler KL. On the theory of the indicator-dilution method for measurement of blood flow and volume. J Appl Physiol 1954, 6:731-744.
    • (1954) J Appl Physiol , vol.6 , pp. 731-744
    • Meier, P.1    Zierler, K.L.2
  • 18
    • 0015157078 scopus 로고
    • Regional cerebral blood flow in man determined by the initial slope of the clearance of intra-arterially injected 133Xe
    • Olesen J, Paulson OB, Lassen NA. Regional cerebral blood flow in man determined by the initial slope of the clearance of intra-arterially injected 133Xe. Stroke 1971, 2:519-540.
    • (1971) Stroke , vol.2 , pp. 519-540
    • Olesen, J.1    Paulson, O.B.2    Lassen, N.A.3
  • 19
    • 0015053361 scopus 로고
    • Measurement of cutaneous blood flow by freely diffusible radioactive isotopes
    • Methodological studies of the washout of krypton-85 and 133-xenon from the cutaneous tissue in man. Thesis, University of Copenhagen
    • Sejrsen P. Measurement of cutaneous blood flow by freely diffusible radioactive isotopes. Dan Med Bull 1971, 18(Suppl.):9-38. Methodological studies of the washout of krypton-85 and 133-xenon from the cutaneous tissue in man. Thesis, University of Copenhagen
    • (1971) Dan Med Bull , vol.18 , Issue.SUPPL. , pp. 9-38
    • Sejrsen, P.1
  • 20
    • 70350421480 scopus 로고
    • Blood flow measured by 133-Xenon washout from skeletal muscle
    • I: Kredsløbets centrale og lokale regulation samt Den mikrovaskulære stofudveksling mellem blod og væv. Festskrift fra symposium for P.P.Eskildsen, Københavns Amts Sygehus i Gentofte, pp
    • Sejrsen P. Blood flow measured by 133-Xenon washout from skeletal muscle. 1982, 22-26. I: Kredsløbets centrale og lokale regulation samt Den mikrovaskulære stofudveksling mellem blod og væv. Festskrift fra symposium for P.P.Eskildsen, Københavns Amts Sygehus i Gentofte, pp
    • (1982) , pp. 22-26
    • Sejrsen, P.1
  • 21
    • 70350397673 scopus 로고    scopus 로고
    • The heat wash-in and heat wash-out technique for quantitative, non-invasive measurement of cutaneous blood flow rate
    • In, eds, pp, Taylor & Francis, London and New York
    • Sejrsen P, Midttun M, Serup J, Jemec GBE, Grove GL. The heat wash-in and heat wash-out technique for quantitative, non-invasive measurement of cutaneous blood flow rate. Non-invasive methods and the skin 2006, 723-731. In, eds, pp, Taylor & Francis, London and New York
    • (2006) Non-invasive methods and the skin , pp. 723-731
    • Sejrsen, P.1    Midttun, M.2    Serup, J.3    Jemec, G.B.E.4    Grove, G.L.5
  • 22
    • 0014287335 scopus 로고
    • Inert gas diffusion method for measurement of blood flow using saturation techniques. Comparison with directly measured blood flow in isolated gastrocnemius muscle of the cat
    • Sejrsen P, Tønnesen KH. Inert gas diffusion method for measurement of blood flow using saturation techniques. Comparison with directly measured blood flow in isolated gastrocnemius muscle of the cat. Circ Res 1968, 22:679-693.
    • (1968) Circ Res , vol.22 , pp. 679-693
    • Sejrsen, P.1    Tønnesen, K.H.2
  • 23
    • 0015394525 scopus 로고
    • Shunting by difusion of inert gas in skeletal muscle
    • Sejrsen P, Tønnensen KH. Shunting by difusion of inert gas in skeletal muscle. Acta Physicol Scand 1972, 86:89-91.
    • (1972) Acta Physicol Scand , vol.86 , pp. 89-91
    • Sejrsen, P.1    Tønnensen, K.H.2
  • 24
    • 84939082594 scopus 로고
    • Researches on the circulation time and on the influences which affect it. IV. The output of the heart
    • Stewart GN. Researches on the circulation time and on the influences which affect it. IV. The output of the heart. J Physiol 1898, 22:159-183.
    • (1898) J Physiol , vol.22 , pp. 159-183
    • Stewart, G.N.1
  • 25
    • 0028058811 scopus 로고
    • Myocardial blood flow rate and capillary permeability for 99mTc-DTPA in patients with angiographically normal coronary arteries. Evaluation of the single-injection, residue detection method with intracoronary indicator bolus injection and the use of a mobile gamma camera
    • Svendsen JH, Kelbaek H, Efsen F, Saunamaki KI, Hoilund-Carlsen PF, Haunso S. Myocardial blood flow rate and capillary permeability for 99mTc-DTPA in patients with angiographically normal coronary arteries. Evaluation of the single-injection, residue detection method with intracoronary indicator bolus injection and the use of a mobile gamma camera. Cardiology 1994, 85:161-170.
    • (1994) Cardiology , vol.85 , pp. 161-170
    • Svendsen, J.H.1    Kelbaek, H.2    Efsen, F.3    Saunamaki, K.I.4    Hoilund-Carlsen, P.F.5    Haunso, S.6
  • 27
    • 0014720250 scopus 로고
    • Washout of 133xenon after intramuscular injection and direct measurement of blood flow in skeletal muscle
    • Tønnesen KH, Sejrsen P. Washout of 133xenon after intramuscular injection and direct measurement of blood flow in skeletal muscle. J Clin Lab Invest 1970, 25:71-81.
    • (1970) J Clin Lab Invest , vol.25 , pp. 71-81
    • Tønnesen, K.H.1    Sejrsen, P.2
  • 28
    • 0034352159 scopus 로고    scopus 로고
    • Indicator dilution methods for measuring blood flow, volume, and other properties of biological systems: a brief history and memoir
    • Zierler K. Indicator dilution methods for measuring blood flow, volume, and other properties of biological systems: a brief history and memoir. Ann Biomed Eng 2000, 28:836-848.
    • (2000) Ann Biomed Eng , vol.28 , pp. 836-848
    • Zierler, K.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.