Volumn 45, Issue 2, 2010, Pages 461-472

Experimental study of cooling effects of a passive evaporative cooling wall constructed of porous ceramics with high water soaking-up ability

Author keywords

Capillary attraction; Evaporative cooling; Heat island; Passive cooling wall; Porous ceramics; Water soaking up

Indexed keywords

CAPILLARY ATTRACTION; EVAPORATIVE COOLING; HEAT ISLAND; PASSIVE COOLING WALL; POROUS CERAMICS; WATER SOAKING-UP;

EID: 70350210512     PISSN: 03601323     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.buildenv.2009.07.002     Document Type: Article
Times cited : (84)

References (12)
  • 2
    • 38249031048 scopus 로고
    • Assessment of natural cooling potential for buildings in different climatic conditions
    • Kishore V.V.N. Assessment of natural cooling potential for buildings in different climatic conditions. Building and Environment 23 3 (1988) 215-223
    • (1988) Building and Environment , vol.23 , Issue.3 , pp. 215-223
    • Kishore, V.V.N.1
  • 3
    • 0023600383 scopus 로고
    • The application of the transwall to horticultural glasshouses
    • Nisbet S.K., and Kwan C.M. The application of the transwall to horticultural glasshouses. Solar Energy 39 6 (1987) 473-482
    • (1987) Solar Energy , vol.39 , Issue.6 , pp. 473-482
    • Nisbet, S.K.1    Kwan, C.M.2
  • 5
    • 65949105214 scopus 로고    scopus 로고
    • Experimental evaluation of the evaporative cooling effect produced by practical application of a feed water-supplied passive cooling wall made of water-permeable ventilable bricks
    • p. 310-316
    • Hoyano A., and Shirai K. Experimental evaluation of the evaporative cooling effect produced by practical application of a feed water-supplied passive cooling wall made of water-permeable ventilable bricks. Proceedings of ISES 1997 solar world congress, Taejon, Korea (1997) p. 310-316
    • (1997) Proceedings of ISES 1997 solar world congress, Taejon, Korea
    • Hoyano, A.1    Shirai, K.2
  • 6
    • 65949121641 scopus 로고    scopus 로고
    • A 3D CAD-based simulation tool for prediction and evaluation of the thermal improvement effect of passive cooling walls in the developed urban locations
    • He J., and Hoyano A. A 3D CAD-based simulation tool for prediction and evaluation of the thermal improvement effect of passive cooling walls in the developed urban locations. Solar Energy 83 7 (2009) 1064-1075
    • (2009) Solar Energy , vol.83 , Issue.7 , pp. 1064-1075
    • He, J.1    Hoyano, A.2
  • 7
    • 0036833019 scopus 로고    scopus 로고
    • Modeling and optimal design of evaporative cooling system in controlled environment greenhouse
    • Jain D., and Tiwari G.N. Modeling and optimal design of evaporative cooling system in controlled environment greenhouse. Energy Conversion and Management 43 16 (2002) 2235-2250
    • (2002) Energy Conversion and Management , vol.43 , Issue.16 , pp. 2235-2250
    • Jain, D.1    Tiwari, G.N.2
  • 8
    • 0038377654 scopus 로고    scopus 로고
    • Modeling and experimental validation of a greenhouse with evaporative cooling by moving water film over external shade cloth
    • Ghosal M.K., Tiwari G.N., and Srivastava N.S.L. Modeling and experimental validation of a greenhouse with evaporative cooling by moving water film over external shade cloth. Energy and Buildings 35 8 (2003) 843-850
    • (2003) Energy and Buildings , vol.35 , Issue.8 , pp. 843-850
    • Ghosal, M.K.1    Tiwari, G.N.2    Srivastava, N.S.L.3
  • 9
    • 37349123553 scopus 로고    scopus 로고
    • Experimental study of effect of an inner thermal curtain in evaporative cooling system of a cascade greenhouse
    • Shukla A., Tiwari G.N., and Sodha M.S. Experimental study of effect of an inner thermal curtain in evaporative cooling system of a cascade greenhouse. Solar Energy 82 1 (2008) 61-72
    • (2008) Solar Energy , vol.82 , Issue.1 , pp. 61-72
    • Shukla, A.1    Tiwari, G.N.2    Sodha, M.S.3
  • 10
    • 38949102337 scopus 로고    scopus 로고
    • A numerical simulation method for analyzing the thermal improvement effect of super-hydrophilic photocatalyst-coated building surfaces with water film on the urban/built environment
    • He J., and Hoyano A. A numerical simulation method for analyzing the thermal improvement effect of super-hydrophilic photocatalyst-coated building surfaces with water film on the urban/built environment. Energy and Buildings 40 6 (2008) 968-978
    • (2008) Energy and Buildings , vol.40 , Issue.6 , pp. 968-978
    • He, J.1    Hoyano, A.2
  • 11
    • 70350148479 scopus 로고    scopus 로고
    • Gas permeability of the porous alumina ceramics with uni-directionally aligned pores by extrusion method
    • Toya T., Kameshima Y., Yasumori A., and Okada K. Gas permeability of the porous alumina ceramics with uni-directionally aligned pores by extrusion method. Journal of European Ceramics Society 27 1 (2007) 53-59
    • (2007) Journal of European Ceramics Society , vol.27 , Issue.1 , pp. 53-59
    • Toya, T.1    Kameshima, Y.2    Yasumori, A.3    Okada, K.4
  • 12
    • 38149108923 scopus 로고    scopus 로고
    • Water-retention properties of porous ceramics prepared from mixtures of allophane and vermiculite for materials to counteract heat island effects
    • Okada K., Matsui S., Isobe T., Kameshima Y., and Nakajima A. Water-retention properties of porous ceramics prepared from mixtures of allophane and vermiculite for materials to counteract heat island effects. Ceramics International 34 2 (2008) 345-350
    • (2008) Ceramics International , vol.34 , Issue.2 , pp. 345-350
    • Okada, K.1    Matsui, S.2    Isobe, T.3    Kameshima, Y.4    Nakajima, A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.