메뉴 건너뛰기




Volumn , Issue , 2009, Pages 2433-2436

Design and characterization of a silver-enhanced gold nanoparticle-based biochip

Author keywords

Biochip; Gold nanoparticle; Micro electrodes array; Silver enhancement

Indexed keywords

CONCENTRATION OF; DETECTION LIMITS; DETECTION METHODS; GOLD NANOPARTICLE; GOLD NANOPARTICLES; HIGH-DENSITY; HIGH-SENSITIVITY; IMMUNOCHROMATOGRAPHIC ASSAYS; INTERDIGITAL; LABELING METHODS; MEASURED RESULTS; MEASUREMENT METHODS; MICRO-ELECTRODES ARRAY; MICROELECTRODE ARRAY; SIGNAL AMPLIFICATIONS; SILVER ENHANCEMENT;

EID: 70350173902     PISSN: 02714310     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ISCAS.2009.5118292     Document Type: Conference Paper
Times cited : (1)

References (11)
  • 1
    • 0040778987 scopus 로고    scopus 로고
    • Food and Drug Administration, Arlington, VA: Association of Analytical Chemists
    • Food and Drug Administration, "Bacteriological Analytical Manual. 8th ed., " Arlington, VA: Association of Analytical Chemists, 2000.
    • (2000) Bacteriological Analytical Manual. 8th ed
  • 2
    • 34249093580 scopus 로고    scopus 로고
    • Characterization and Optimization of Gold Nanoparticle-Based Silver-Enhanced Immunoassays
    • S. Gupta, S. Huda, P. K. Kilpatrick, and O. D. Velev, "Characterization and Optimization of Gold Nanoparticle-Based Silver-Enhanced Immunoassays," Anal. Chem, Vol. 79, No. 10, pp. 3810-3820, 2007.
    • (2007) Anal. Chem , vol.79 , Issue.10 , pp. 3810-3820
    • Gupta, S.1    Huda, S.2    Kilpatrick, P.K.3    Velev, O.D.4
  • 3
    • 0034756339 scopus 로고    scopus 로고
    • Colloidal Gold-based Immunochromatographic Assay for Detection of Ricin
    • R. H. Shyu, H. F. Shyu, H. W. Liu, S. S. Tang, "Colloidal Gold-based Immunochromatographic Assay for Detection of Ricin," Toxicon, Vol. 40, No. 3, pp. 255-258, 2002.
    • (2002) Toxicon , vol.40 , Issue.3 , pp. 255-258
    • Shyu, R.H.1    Shyu, H.F.2    Liu, H.W.3    Tang, S.S.4
  • 4
    • 0032663168 scopus 로고    scopus 로고
    • In Situ Assembly of Colloidal Particles into Miniaturized Biosensors
    • O. D. Velev and E. W. Kaler, "In Situ Assembly of Colloidal Particles into Miniaturized Biosensors, Langmuir, Vol. 15, No. 11, pp. 3693-3698, 1999.
    • (1999) Langmuir , vol.15 , Issue.11 , pp. 3693-3698
    • Velev, O.D.1    Kaler, E.W.2
  • 5
    • 17844398734 scopus 로고    scopus 로고
    • Femtomolar Immunoassay based on Coupling Gold Nanoparticle Enlargement with Square Wave Stripping Voltammetry
    • K. T. Liao and H. J. Huang, "Femtomolar Immunoassay based on Coupling Gold Nanoparticle Enlargement with Square Wave Stripping Voltammetry," Analytica chimica acta, Vol. 538, No. 1-2, pp. 159-164, 2005.
    • (2005) Analytica chimica acta , vol.538 , Issue.1-2 , pp. 159-164
    • Liao, K.T.1    Huang, H.J.2
  • 7
    • 0034141654 scopus 로고    scopus 로고
    • Conductimetric Membrane Strip Immunosensor with Polyaniline-bound Gold Colloids as Signal Generator
    • J. -H. Kim, J. -H. Cho, S. C. Geun, C. -W. Lee, H. -B. Kim, S. -H. Peak, "Conductimetric Membrane Strip Immunosensor with Polyaniline-bound Gold Colloids as Signal Generator," Biosensors and Bioelectronics, Vol. 14, No. 12, pp. 907-915, 2000.
    • (2000) Biosensors and Bioelectronics , vol.14 , Issue.12 , pp. 907-915
    • Kim, J.-H.1    Cho, J.-H.2    Geun, S.C.3    Lee, C.-W.4    Kim, H.-B.5    Peak, S.-H.6
  • 8
    • 11144231293 scopus 로고    scopus 로고
    • A High Density Microelectrode Array Biosensor for Detection of E. coli O157:H7
    • S. M. Radke and E. C. Alocilja, "A High Density Microelectrode Array Biosensor for Detection of E. coli O157:H7," Biosensors and Bioelectronics, Vol. 20, No. 8, pp. 1662-1667, 2005.
    • (2005) Biosensors and Bioelectronics , vol.20 , Issue.8 , pp. 1662-1667
    • Radke, S.M.1    Alocilja, E.C.2
  • 9
    • 0037154825 scopus 로고    scopus 로고
    • Array-Based Electrical Detection of DNA with Nanoparticle Probes
    • S. J. Park, T. A. Taton, C. A. Mirkindagger, "Array-Based Electrical Detection of DNA with Nanoparticle Probes, Science, Vol. 295, No. 5559, pp. 1503-1506, 2002.
    • (2002) Science , vol.295 , Issue.5559 , pp. 1503-1506
    • Park, S.J.1    Taton, T.A.2    Mirkindagger, C.A.3
  • 10
    • 0024596397 scopus 로고
    • Use of Thiol-terminal Silanes and Heterobifunctional Crosslinkers for Immobilization of Antibodies on Silica Surfaces
    • S. K. Bhatia, L. C. Shriver-Lake, K. J. Prior, J. H. Georger, J. M. Calvert, R. Bredehorst, and F. S. Ligler, "Use of Thiol-terminal Silanes and Heterobifunctional Crosslinkers for Immobilization of Antibodies on Silica Surfaces," Analytical Biochemistry, Vol. 178, Issue 2, pp. 408-413, 1989.
    • (1989) Analytical Biochemistry , vol.178 , Issue.2 , pp. 408-413
    • Bhatia, S.K.1    Shriver-Lake, L.C.2    Prior, K.J.3    Georger, J.H.4    Calvert, J.M.5    Bredehorst, R.6    Ligler, F.S.7
  • 11
    • 34748894218 scopus 로고    scopus 로고
    • Y. Liu, S. Chakrabartty, and E. C. Alcilja, Fundamental Building Blocks for Molecular Bio-wire based Forward-error Correcting Biosensors, Nanotechnology, 18, No. 42, pp. 424017(6pp), October 24, 2007.
    • Y. Liu, S. Chakrabartty, and E. C. Alcilja, "Fundamental Building Blocks for Molecular Bio-wire based Forward-error Correcting Biosensors," Nanotechnology, vol. 18, No. 42, pp. 424017(6pp), October 24, 2007.